QUICK START GUIDE

Breakout Network TAP | M1GCCB

Definitions

Synchronization Mode:

DIP Switch 1 and 2 in OFF position. When in Synchronization Mode, all ports of

the M1GCCB TAP are Auto MDI/MDIX, Auto Speed and Auto Duplex automatically. The TAP will
synchronize to determine the highest supported network speed, drop link across all ports, and then only
advertise and link to the highest supported common speed on all ports. Places the TAP in full auto mode.

1G, 100M or 10M Speed Mode:

(See table for Switch positions) When one of the Speed Settings are

selected then you have the option to select the Duplex (AUTO or FULL) and whether to have LFP turned
on or not.

Link Failure Propagation (LFP):

Used mostly for HA designed networks. It can sense a network failure

and reflect the failure to the other side of the network allowing the network s failover mechanism to switch
over to the secondary network path.

Duplex:

AUTO setting (Switch 3 in ON position default) lets the port negotiate the duplex mode with the

link pair (only in copper connections).

FULL setting forces the link to full duplex mode

Breakout:

An operating mode that allows monitoring of separate traffic streams, one for each direction of

network traffic.

FailSafe:

On power loss, live network tap ports reestablish link with each other, resuming traffic flow

between critical network devices.

FailSafe Operation