background image

Dual Nx56/64
Option Module

 PN 1200142L1#HS

Plug-On Board PN 1200159L1

 USER MANUAL

61200142L1-1C
August 2000

Summary of Contents for DUAL Nx56/64 1200142L1#

Page 1: ...Dual Nx56 64 Option Module PN 1200142L1 HS Plug On Board PN 1200159L1 USER MANUAL 61200142L1 1C August 2000 ...

Page 2: ...Trademark T Watch ProTM is a registered trademark of ADTRAN 901 Explorer Boulevard P O Box 140000 Huntsville AL 35814 4000 Phone 256 963 8000 2000 ADTRAN Inc All rights reserved Printed in USA ...

Page 3: ... provide additional useful information Cautions signify information that could prevent service interrup tion Warnings provide information that could prevent damage to the equipment or endangerment to human life ...

Page 4: ...se the user will be required to correct the interference at his own expense Shielded cables must be used with this unit to ensure compliance with Class A FCC limits Warranty and Customer Service ADTRAN will replace or repair this product within five 5 years from the date of shipment if it does not meet its published specifications or fails while in service For detailed warranty repair and return i...

Page 5: ...nty becomes null and void if Customer modifies or alters the equip ment in any way other than as specifically authorized by ADTRAN EXCEPT FOR THE LIMITED WARRANTY DESCRIBED ABOVE THE FORE GOING CONSTITUTES THE SOLE AND EXCLUSIVE REMEDY OF THE CUS TOMER AND THE EXCLUSIVE LIABILITY OF ADTRAN AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED ADT RAN SPECIFICALLY DISCLAIMS ALL OTHER ...

Page 6: ...vi ...

Page 7: ... Module 1 2 Interfaces 1 2 Dual Nx56 64 V 35 Option Module Specifications 1 3 DTE Interface 1 3 Rates 1 3 Clock Options 1 3 Tests 1 3 Test Pattern 1 3 Data Inversion 1 3 1s Density Protection 1 3 CTS DCD DSR Options 1 3 Connector 1 3 Inband Communication Channel 1 4 Physical Description 1 4 Chapter 2 Installation 2 1 Unpack Inspect 2 1 ADTRAN Shipments Include 2 1 Installing the Option Module 2 2 ...

Page 8: ...s 3 5 Port Rate 3 5 PORT CONFIG 3 6 Operation 3 6 Interface 3 6 Rate 56 64 3 7 Transmit Clock TX CLK 3 7 Data 3 7 Clear to Send CTS 3 7 Data Carrier Detect DCD 3 7 Data Set Ready DSR 3 7 0 INHIB 3 8 INBAND 3 8 TX CLK SOURCE 3 9 Factory Restore 3 10 Operation 3 10 Port Utility 3 10 Operation 3 10 Run Self Test 3 11 Port Test 3 12 Operation 3 12 1 1 Dual Nx56 64 3 12 LOOPBK 3 12 REM V 54 CONT 3 13 5...

Page 9: ...Table of Contents 61200142L1 1 Dual Nx 56 64 Option Module User Manual ix Index Index 1 ...

Page 10: ...Table of Contents x Dual Nx 56 64 Option Module User Manual 61200142L1 1 ...

Page 11: ...gure 2 2 Attaching the Plug On Board 2 3 Figure 3 1 TSU 100 Main Menu Tree 3 2 Figure 3 2 Dual Nx56 64 V 35 Menu Tree 3 3 Figure 3 3 Port Status Submenu 3 4 Figure 3 4 Port Configuration Submenu 3 6 Figure 3 5 Inband Remote Configuration 3 9 Figure 3 6 Port Utility Submenu 3 10 Figure 3 7 Port Name and Software Version Display 3 11 Figure 3 8 Port Test Submenu 3 12 ...

Page 12: ...List of Figures xii Dual Nx 56 64 Option Module User Manual 61200142L1 1 ...

Page 13: ...0142L1 1 Dual Nx 56 64 Option Module User Manual xiii List of Tables Table 2 1 Subminiature D Connection 2 4 Table 3 1 Normal Mode Operation 3 8 Table B 1 26 Pin Subminiature D to V 35 Winchester Cable B 2 ...

Page 14: ...List of Tables xiv Dual Nx 56 64 Option Module User Manual 61200142L1 1 ...

Page 15: ... 64 V 35 option module installs in the op tion slot of the TSU TDU ESU family of products and provides two additional synchronous V 35 interface ports When used in these products this interface port al lows two additional DTEs to have access to the T1 service DUAL NX56 64 V 35 PLUG ON BOARD OVERVIEW The operations of the Dual Nx56 64 V 35 option module described in this manual are also applicable ...

Page 16: ...and are automat ically installed when either is plugged into a TSU TDU ESU product Features of the Dual Nx56 64 V 35 Option Module Operates using one to twenty four DS0s 32 in E1 Includes an elastic store for absorption of rate varia tions Outputs a 50 percent duty cycle output clock at all rates Menu operation for easy configuration Executes and responds to V 54 looping codes Generates and checks...

Page 17: ... 56 kbps to 1 536 Mbps T1 and 2048 Mbps E1 in 56K or 64K steps Clock Options Normal Inverted Tests Local Loopback Bilateral Menu activated Remote Loopback V 54 Menu activated Self test Test Pattern 511 with errored seconds display and error inject capabil ity Data Inversion Menu selectable 1s Density Protection Force 1s to network after one second of consecutive zeros from DTE Choices On or Off CT...

Page 18: ...added to the Dual Nx56 64 option module creating a multiport module ThePORT X 1 and X 2 indication is linked to the port numbering philoso phy of the TSU TDU ESU product family The X repre sents the slot number into which the option module is plugged For the TSU 1X0 there is only one option slot Therefore the port designations are 1 1 1 2 and if a Dual Nx56 64 Plug On V 35 option module is present...

Page 19: ...ping the op tion module or plug on board back for repair or for veri fication of damage during shipment See product support information on the back page of this manual for informa tion on how to contact ADTRAN ADTRAN Shipments Include The Dual Nx56 64 Module or Dual Nx56 64 Plug on Board The Dual Nx56 64 Option Module User Manual to be inserted into the main TSU TDU ESU User Manual Two interface c...

Page 20: ...ule Perform the following steps to install the option module 1 Remove the cover plate from the TSU TDU ESU unit rear panel 2 Slide the option module into the rear panel of the TSU TDU ESU unit until it is positioned firmly against the front of the unit 3 Fasten the thumbscrews at both edges of the option module Figure 2 1 Installing the Option Module TSU TDU ESU UNIT Option Module Cover Plate ...

Page 21: ...teps to install the plug on board 1 Hold the plug on board above the option module 2 Using a downward and right to left motion slip the plug on board connector into opening in the option module back panel 3 Moving the plug on board downward secure the connection of the header pins at the front of the boards 4 Install two 4 40 screws at both front edges of the option module 5 Install two 4 40 screw...

Page 22: ... damage to the equipment Table 2 1 Subminiature D Connection PIN DESCRIPTION 1 Protective ground PG 4 Request to send RTS from DTE 5 Clear to send CTS to DTE 6 Data set ready DSR to DTE 7 Signal ground SG 8 Received line signal detector DCD to DTE 9 Transmitted data TD A to DTE 10 Transmitted data TD B to DTE 11 Received data RD A to DTE 12 Received data RD B to DTE 13 External TX clock ETC A from...

Page 23: ...ously configured setting for the op tion module is automatically restored unless the software has changed revision When the self testing is completed and the configuration is successfully restored the LED labeled OK in the mod ule group on the front panel turns On For more informa tion see Front Panel Operation in the Operation chapter of the appropriate TSU TDU ESU user manual If any alarms are d...

Page 24: ...Chapter 2 Installation 2 6 Dual Nx56 64 Option Module User Manual 61200142L1 1 ...

Page 25: ...uttons in the appropriate user manual Menu Structure The Dual Nx56 64 V 35 option module menus appear as a subset of and operate the same as menus for the TSU TDU ESUs The menus for the Dual Nx56 64 option module are accessed by selecting the following from the Port menu SLOT PORT NX56 64 Slot SLOT is the slot number in which the option module is in stalled In the TSU unit with one option card slo...

Page 26: ...enu items printed in bold italics The main menu for the other TSU TDU ESU units operates in a similar way See Appendix A in the TSU 100 User Manual for a complete menu tree diagram Figure 3 1 TSU 100 Main Menu Tree 1 STATUS 1 NI PERF RPTS 2 NI ERRORS 1 NETWORK NI 3 ACTIVE ALARMS 2 UNIT 4 VIEW HISTORY 3 MAP XCHNG 5 PORT STATUS 2 CONFIG 4 MAP IN USE A B 6 REMOTE PORT 5 DS0 MAP A 7 CLEAR PORT ALARM 6...

Page 27: ... are submenu choices for Dual Nx56 64 V 35 option modules see Figure 3 2 Each of these submenu items is discussed in the following para graphs All are accessed by the same method Figure 3 2 Dual Nx56 64 V 35 Menu Tree 1 DTE DATA CLOCK 2 DTE STATUS 1 STATUS 2 PORT STATUS 3 PORT RATE 1 INTERFACE 2 RATE 3 TX CKL CNTRL 2 CONFIG 7 PORT CONFIG 4 DATA DUAL 5 CTS NX56 64 MENU 6 DCD 7 DSR 8 0 INHIB 9 INBAN...

Page 28: ...tus of the TSU 100 operation It displays the status of the moni tored signal line on the Dual Nx56 64 V 35 option board and the data rate for which the option module is config ured Operation To display Figure 3 3 on the TSU 100 place the cursor on main menu item 1 STATUS and do the following 1 Press Enter or the number 1 key This displays the first two Status submenu items with the cursor on 1 NI ...

Page 29: ...ows the status active or not active of the following lines DTE Status Shows the status active or not active of the following lines Port Rate Displays the data rate to which the NX port is set Exit the displays as described in the TSU 100 User Manual TXD Transmit data from the DTE RXD Receive data to the DTE ETC External transmit clock from DTE LCK Lock status of the phase locked loop RTS Request t...

Page 30: ... Configuration submenu items with the cur sor on 1 NETWORK NI 2 Use the down arrow key to place the cursor on 7 PORT CONFIG and press Enter 3 Use the up and down arrow keys to identify 1 1 DUAL NX56 64 V 35 option module Only the bottom line of the display changes Figure 3 4 Port Configuration Submenu To select PORT CONFIGURATION press Enter This displays the first of eight submenu items They are ...

Page 31: ...of the clock which should compensate for a long cable Choices Normal Inverted Data Used to control the inverting of the DTE data This inversion can be useful when operating with a high level data link HDLC protocol Often used as a means to ensure 1s density Choices Normal or Inverted Clear to Send CTS Used to control characteristics of CTS Choices Normal or Force On see Table 3 1 on page 3 8 Data ...

Page 32: ...ock rate is reduced by 8 kbps The TSU HSU uses this 8 kbps channel to send and receive configura tion data across a T1 span As shown in Figure 3 5 this allows the PC connected to the chain in port on TSU 600 A to monitor configure both TSU 600 A and B This fea ture is useful when FDL connectivity is not available across the T1 span The 8 kbps channel is only taken out of the first DS0 If two 64K D...

Page 33: ... the DTE Normally this is set to INTERNAL If the DTE provides a clock with TX data the clock selection is set to EXTERNAL The Nx56 64 will depend on an externally supplied clock to accept the TX data Choices INTERNAL or EXTERNAL Figure 3 5 Inband Remote Configuration TSU 600 A NX DSX 1 CHAIN IN ROUTER PBX TSU 600 B NX DSX 1 ROUTER PBX NETWORK T WATCH Although a router can accommodate this 8K rate ...

Page 34: ...the 3 UTIL menu items 2 With the cursor on 2 FACT RESTORE press Enter Port Utility The Port Utility submenu is used primarily to access the display of the current software information for each port installed in the unit This information is required when requesting assistance from ADTRAN Technical Support or when updates are needed Operation To display Figure 3 6 do the following 1 Follow the stand...

Page 35: ...7 Port Name and Software Version Display Run Self Test This menu item is used to execute both the internal test of the TSU TDU ESU and of the Dual Nx56 64 This is the same test executed during power up The results of the self test are shown on the TSU 100 display For additional information on Self Test see the Operation chapter of the appropriate TSU TDU ESU user manual To activate a self test do ...

Page 36: ...U ESU display Operation To display Figure 3 8 on the TSU 100 place the cursor on 3 PORT TEST and press Enter or the number 3 key This displays the available ports Figure 3 8 Port Test Submenu 1 1 Dual Nx56 64 The Nx interface offers the following test functions LOOPBK Initiates a loopback PRT LCI The Nx port activates both a local loopback Back toward the DTE and a port loopback when either is inv...

Page 37: ... test pattern ON The pattern check circuitry is enabled and test started The test is ended by selecting OFF OFF The pattern generation and check is disabled DIS 511 RESLT Displays the results of the 511 test indicated above The results are in the form of the number of errored seconds The error count can be cleared by pressing the Clear key Shift 9 A bit error may be inserted into the data stream b...

Page 38: ...Chapter 3 Operation 3 14 Dual Nx56 64 Option Module User Manual 61200142L1 1 ...

Page 39: ...stem Messages ALARM MESSAGES Network Interface NI Red Alarm NI unable to align frame with incoming signal Yellow Alarm Remote alarm indication RAI being received from the far end Blue Alarm Unframed all 1s AIS being received at NI Loss of Signal No signal detected at NI ...

Page 40: ...ock on the clock provided by the network interface Zeros Alarm All 0s data being sent to the network interface No EXT Clock No external transmit clock at DTE when applicable STATUS MESSAGES Network Interface NI Payload On Payload loopback activated Line On Line loopback activated Loopback Off All loopbacks deactivated Factory Restore Factory setting restored Power On Unit powered on Self Test Inte...

Page 41: ...twork interface and the DTE interface of the card Remote Loop Up Sending a V 54 pattern in an attempt to loop up a remote device 511 Pattern On Sending a 511 pattern towards the network interface Loop Down Data is no longer looped back at the network interface or the DTE interface 511 Pattern Off No longer sending a 511 pattern towards the network interface ...

Page 42: ...Appendix A System Messages A 4 Dual Nx56 64 Option Module User Manual 61200142L1 1 ...

Page 43: ...ter Cables shipped with the Dual Nx56 64 Option Module and the Dual Nx56 64 Plug On Board are pinned out as shown in Table B 1 on page B 2 Subminiature D connector should be AMP PN 750850 3 or equivalent V 35 Winchester cable should be Positronic PNV3400000 70 with GMCT34F0000YR 695 or equivalent Pins A through NN are V 35 connector pins pins 101 through 114 are CCITT pins ...

Page 44: ... 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Frame Ground NC NC RTS CTS DSR SIGNAL GROUND DCD TD A TD B RD A RD B ETC A NC NC NC RI LL TM DTR SIGNAL GROUND TC A TC B RC A RC B ETC B A 101 B 102 C 105 D 106 E 107 F 109 H J K L M N P 103 R 104 S 103 T 104 U 113 V 115 W 113 X 115 Y 114 Z AA 114 BB CC DD EE FF HH JJ KK LL MM NN Frame Ground Signal Ground RTS CTS DSR DCD DTR RI TM ...

Page 45: ... Dual NX56 64 Status 3 5 Dual Nx56 64 V 35 Menus 3 3 Dual Nx56 64 V 35 overview 1 1 3 1 Dual Nx56 64 V 35 physical description 1 4 dual Nx56 64 V 35 specifications 1 3 Dual Nx56 64 V 35 system messages A 2 F factory restore 3 10 Factory Restore status message A 2 FCC Radio Frequency Interference Statement iv Features Dual Nx56 64 V 35 Option Module 1 2 Front Panel Indicators Buttons See TSU TDU ES...

Page 46: ...LC 3 12 R RATE 56 64 port config 3 7 Red Alarm network interface A 1 REM V 54 CONT 3 13 REMOTE 3 13 Remote Loop Up A 3 Remote Loopback test 1 3 Run Self Test 3 11 S Self Test status message A 2 Self test 1 3 shipping container items contained in 2 1 shipping damages what to do if 2 1 Status Messages A 2 T Test Pattern 1 3 Tests 1 3 Transmit Clock port config 3 7 TX CLK 3 7 TX CLK SOURCE 3 9 U Unpa...

Page 47: ...repair is needed Technical Sup port will coordinate with the Customer and Product Service CaPS department to issue an RMA number For information regarding equipment currently in house or possible fees associated with repair contact CaPS directly at the following num ber Identify the RMA number clearly on the package below address and return to the following address ADTRAN Inc CaPS Department 6767 ...

Page 48: ......

Reviews: