DIMENSIONS AND SPECIFICATIONS Continued

MODEL 

NUMBER

NATURAL GAS

L.P. GAS

Orifice Size

Input=BTU/HR

Orifice Size

Input=BTU/HR

GXC24

31

  2 @ 45,000 

47

  2 @ 45,000 

GXC30

31

  2 @ 45,000

47

  2 @ 45,000

GXC36

31

  3 @ 45,000 

47

  3 @ 45,000 

GXC48

31

  4 @ 45,000

47

  4 @ 45,000

GXC60

31

  4 @ 45,000 

56

  4 @ 18,000 

GXR24

48

  4 @ 18,000 

56

  4 @ 18,000 

GXR30

48

  5 @ 18,000 

56

  5 @ 18,000 

GXR36

48

  6 @ 18,000

56

  6 @ 18,000

GXR48

48

  8 @ 18,000 

56

  8 @ 18,000 

GXR60

48

10 @ 18,000

56

10 @ 18,000

GXR60SP

48

10 @ 18,000

56

10 @ 18,000

Natural Gas Flow Pressure = 5.0” Water Column, measured at manifold tap.

Propane Gas flow pressure = 10.0” Water Column, measured at manifold tap

MODELS AVAILABLE: Char-Glo, Ceramic Coals

SHIPPING INFORMATION

Model No.

Description

Total BTU

Lbs/Kg

Cube Dimensions

(LxDxH) In(mm)

GXC24

24" Wide Broiler

90,000

283/128 30(762) x 40(1016) x 27(656)

GXC30

30" Wide Broiler

90,000

338/153

36(914) x 40(1016) x 27(656)

GXC36

36" Wide Broiler

135,000

391/177 42(1067) x 40(1016) x 27(656)

GXC48

48" Wide Broiler

180,000

505/229 54(1372) x 40(1016) x 27(656)

GXC60

60" Wide Broiler

180,000

620/281 60(1524) x 40(1016) x 27(656)

MODELS AVAILABLE: Cast Iron Radiants

SHIPPING INFORMATION

Model No.

Description

Total BTU

Lbs/Kg

Cube Dimensions

(LxDxH) In(mm)

GXR24

24" Wide Broiler

72,000

265/120 30(762) x 40(1016) x 27(656)

GXR30

30" Wide Broiler

90,000

320/145

36(914) x 40(1016) x 27(656)

GXR36

36" Wide Broiler

108,000

360/163 42(1067) x 40(1016) x 27(656)

GXR48

48" Wide Broiler

144,000

469/213 54(1372) x 40(1016) x 27(656)

GXR60

60" Wide Broiler

180,000

581/264 60(1524) x 40(1016) x 27(656)

Содержание GXC24

Страница 1: ...d by a Garland authorized service agent using genuine Garland replacement parts Garland will have no obligation with respect to any product that has been improperly installed adjusted operated or not maintained in accordance with national and local codes or installation instructions provided with the product or any product that has its serial number defaced obliterated or removed or which has been...

Страница 2: ...Part 9229077 07 05 Page ...

Страница 3: ...oning And Setup 7 Air Supply And Ventilation 7 Gas Connection 7 Manual Shut off Valve 7 Pressure Regulator 7 Rigid Connections 8 Flexible Couplings Connectors 8 Manual Pilot Valve 8 Initial Pilot Light 9 Shut Down 9 Final Preparation 9 Cleaning And Maintenance 9 Daily GXC Series 9 Daily GXR Series 10 Periodic 10 Cleaning Stainless Steel 10 Service And Parts 10 ...

Страница 4: ...ssionally trained personnel Description GXC SERIES GXR SERIES 24 30 36 48 60 24 30 36 48 60 Width In mm 24 610 30 762 36 914 48 1219 60 1524 24 610 30 762 36 914 48 1219 60 1524 Depth In mm 31 3 8 797 All Models Height In mm 20 508 All Models No Burners 2 2 3 4 4 4 5 6 8 10 BTU Hr Nat Pro 90 000 90 000 135 000 180 000 180 000 72 000 90 000 108 000 144 000 180 000 Gas Manifold 3 4 NPT 3 4 NPT 3 4 N...

Страница 5: ...Coals SHIPPING INFORMATION Model No Description Total BTU Lbs Kg Cube Dimensions LxDxH In mm GXC24 24 Wide Broiler 90 000 283 128 30 762 x 40 1016 x 27 656 GXC30 30 Wide Broiler 90 000 338 153 36 914 x 40 1016 x 27 656 GXC36 36 Wide Broiler 135 000 391 177 42 1067 x 40 1016 x 27 656 GXC48 48 Wide Broiler 180 000 505 229 54 1372 x 40 1016 x 27 656 GXC60 60 Wide Broiler 180 000 620 281 60 1524 x 40 ...

Страница 6: ...as In the event you have any questions concerning the installation use care or service of the product write or call our Product Service Department WARNING All Garland Char Broilers must be connected only to the type of gas identified on the rating plate INSTALLATION General Installation IMPORTANT Safe and satisfactory operation of your equipment depends to a great extent on its proper installation...

Страница 7: ...oilers must be under a vent hood Filters and drip troughs should be part of any industrial hood but consult local codes before constructing and installing a hood Air movement should be checked during installation Strong exhaust fans in this hood or in the overall air conditioning system can product a slight vacuum in the room and or cause air drafts either of which can interfere with pilot or burn...

Страница 8: ...liances CAN CGA 6 16 and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for Use With Gas Fuel ANSI Z21 41 or Quick Disconnect Devices for Use with Gas Fuel CAN1 6 9 and adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movem...

Страница 9: ...several times until the new lines are purged of any trapped air and constant gas flow is attained Shut Down 1 Turn top burner valves clockwise to OFF position 2 When shutting down for periods longer than overnight turn the manual ON OFF valve on the incoming service line OFF Close all pilot adjusting screws right hand turn all the way in Final Preparation New units are wiped clean with solvent at ...

Страница 10: ...ast the radiants is connected by a second pan covering the reminder of the broiler bottom The front tray must be checked frequently during operation and drained as necessary the rear drip pan should also be checked occasionally Spills should be wiped as they occur and at the end of the day both pans should be washed in hot soapy water Periodic Your Garland Char Broiler should be checked and adjust...

Страница 11: ...Part 9229077 07 05 Page 11 NOTES ...

Страница 12: ......

Отзывы: