background image

 

USER GUIDE

 

 EdgeSafe 10G Modular Bypass  | ​Firmware Rev Level: 0.3.3.2 

 

Variable name 

Variablecode 

(X=) 

Type 

Attributes 

Value 

Description 

ibsSysTacacsKey 

3.29 

OCTET STRING 

(SIZE(8..127)) 

read-write   

Set the Tacacs secret key. Set only 

variable, read will return zero length 

string. 

ibsSysTacacsState 

3.30 

INTEGER 

read-write 

off(1), 

on_clear(2), 

on_encrypted 

(2) 

Show/set TACACS state. 

ibsSysTacacsServerIp 

3.31 

IpAddress 

read-write   

Show/set the IP address of the TACACS 

server. 

ibsSysTelnetState 

3.32 

INTEGER 

read-write 

off(1), 

on(2) 

Show/set Telnet state. 

ibsSysSetMgmtPermitIP 

3.35 

OCTET STRING 

(SIZE(9..2550)) 

read-write   

Add the management port permitted 

network IP address. String consists of IP and 

netmask separated by semicolon 

(192.168.0.0/24;193.151.0.0/22) 

ibsSysRemoveMgmtPermi

tI P 

3.36 

OCTET STRING 

(SIZE(9..2550)) 

read-write   

Remove one or all management port 

permitted network IP. String consists of IP 

address and netmask address separated by 

semicolon (192.168.0.0/24;193.151.0.0/22 | 

all_permitted_ip) 

ibsSysShowMgmtPermitIP 

3.37 

OCTET STRING 

(SIZE(9..2550)) 

read-write   

Display management port permitted

 

 

 

 

network IP. String consists of IP and

 

 

 

     

 

netmask separated by semicolon 

(192.168.0.0/24;193.151.0.0/22) 

ibsSysTacacsMultiUsers 

3.38 

INTEGER 

read-write 

off(1), 

on(2) 

Show/set TACACS multi users state. 

ibsSysSetTrapAccount 

3.39 

OCTET STRING 

(SIZE(9..2550)) 

read-write   

Add the SNMP monitor server trap account. 

String consists of IP addresses, community 

name and password separated by 

semicolon. 

(192.168.0.0/community1/gt82d7yfr; 

193.151.0.0/community2/) 

Take effect after setting ibsSnmpApply. 

ibsSysRemoveTrapAccount 

3.40 

OCTET STRING 

(SIZE(9..2550)) 

read-write   

Remove one or all SNMP monitor server 

trap accounts. String consists of IP 

addresses separated by semicolon. 

(192.168.0.0;193.151.0.0 | 

all_trap_accounts) 

Take effect after setting ibsSnmpApply. 

ibsSysShowTrapAccount 

3.41 

OCTET STRING 

(SIZE(9..2550)) 

read-only 

 

"Display SNMP monitor server trap accounts. 

String consists of IP addresses and 

community name and password separated 

by semicolon. 

(192.168.0.0/community1/**********; 

193.151.0.0/community2/not set) 

ibsSysPowerOff 

3.42 

INTEGER 

read-write 

Poweroff(1) 

Power off the IBS module.Set only 

command, read will return zero. 

ibsSysPwOffState 

3.47 

INTEGER 

read-write 

bypass (2) 

Disconnect (4) 

Device power off state: bypass or disconnect 

ibsSysRxTxErrTrapTimeout 

3.49 

 

read-write 

off(1), 

on(2) 

Enable generating trap on rx/tx error 

 

ibsSysRxTxErrMonAction 

3.50 

 

read-write   

Allow to choose network ports state 

when errors detected on monitor port 

 

ibsSysRxTxErrNetAction 

3.51 

 

read-write   

Allow to choose network ports state when 

errors detected on network ports 

 

ibsSysRxTxErrRateThreshold 

3.52 

 

read-write   

Network ports state that was configured 

will be activated, when error rate threshold 

will be reached (err/sec). Error rate threshold 

value should be set more than zero 

ibsConf2pl 

4.1 

INTEGER 

read-write 

enable (1), 

disable (2) 

Show/Set two-port link mode 

ibsConfHbExpState 

4.2 

INTEGER 

read-write 

bypass(2), 

tap(3), 

linkdrop(4)  

Show/Set heartbeat expiration mode. 

Garland Technology  |  716.242.8500  |  

garlandtechnology.com/support

 

 

         98 

Содержание EdgeSafe M10GMSBPv2

Страница 1: ...G1DCv2 For questions please contact Garland Technology Support at 8AM 9PM CST Monday Friday Except for observed US Holidays Tel 716 242 8500 Online www garlandtechnology com support Garland Technology...

Страница 2: ...tion 8 1 web interface 2 1 15 Apr 10 Updates for firmware 2 0 2 Updates for 48v products 2 2 28 Aug 11 Add show set_rs232_speed command set_link command 2 3 27 Sep 11 Add support for the different TAP...

Страница 3: ...upport for Internal vlan change Add support for M2M 3 2 FW 3 1 5 Add support for Multi SNMP servers Add support for multi NTP servers 3 4 FW 3 1 7 Add support for TACACS authorization read only and re...

Страница 4: ...POWER TO THE AC IBS UNIT 230V 120V 26 5 2 1 Verify that the power switch on the IBS unit is OFF 26 5 2 2 Connect two power cables to the power supplies on to the back of the IBS The PWR led s on the...

Страница 5: ...ANAGEMENT PORT IP ADDRESS 42 6 15 ETHERNET MANAGEMENT PORT NET MASK ADDRESS 42 6 16 ETHERNET MANAGEMENT PORT GATEWAY IP ADDRESS 43 6 17 ETHERNET MANAGEMENT PORT VLAN ID 43 6 18 TIME 44 6 19 SYSTEM USE...

Страница 6: ...efault heartbeat packet content 62 6 51 4 Show Set heartbeat packet transmit direction 63 6 51 5 Show Set criteria for determining heartbeat packet failure 64 6 52 REMOTE LOG 65 6 52 1 Show remote log...

Страница 7: ...range 83 6 62 2 Display permitted IP range 83 6 62 3 Check permitted IP range 83 7 SNMP 84 7 1 SNMP_ENRTY COMMANDS 84 show_snmp_entry To view the current SNMP entry or the view all entries use the co...

Страница 8: ...15 8 6 ACCOUNT PAGE 117 8 6 1 Interface 117 8 6 2 User 117 8 6 3 Password 117 8 6 4 Session timeout 117 8 7 SNMP PAGE 118 8 7 1 SNMP Entry 118 8 7 2 Access 119 Version 3 5 Page 8 of 146 8 7 1 Name 119...

Страница 9: ...guration 139 10 7 2 Linux TFTP server installation and configuration 139 10 8 MANAGEMENT SERIAL RS232 CABLE DRAWING 140 10 9 NET SNMP COPYRIGHT 140 10 10 TACACS COPYRIGHT 145 LIST OF FIGURES Figure 1...

Страница 10: ...supplies or two redundant 48V power supplies 1 1 TarSHOW release P N Description Notes IBS10G SR 10 Gigabit MM Fiber Intelligent Bypass Switch 10G Multimode IBS10G LR 10 Gigabit SM Fiber Intelligent B...

Страница 11: ...he IBS detects the heartbeat packet coming back it maintains the Inline mode state When the EdgeSafe Bypass TAP IBS does not detect the heartbeat packet from the Network Monitor the IBS sets to Bypass...

Страница 12: ...ing power failure of the Monitor Network appliance the heartbeat packets are not transmitted back by the Monitor Network appliance and since the IBS does not receive the heartbeat packet it sets to Ac...

Страница 13: ...ing the heartbeat packets for a period set by the hb_holdtime parameter The hb_holdtime parameter can be changed via the management port from its initial default mode 2 5 Power Failure The IBS support...

Страница 14: ...port NET0 is mirrored to port MON0 and incoming traffic in port NET1 is mirrored to port MON1 Figure 3 EdgeSafe Bypass TAP Mode 2 7 TAPI12 mode The IBS supports TAPI12 Mode when it is enabled incoming...

Страница 15: ...e 10G Modular Bypass Firmware Rev Level 0 3 3 2 injected from port MON0 to port NET0 and from port MON1 to port NET1 Figure 4 EdgeSafe Bypass TAPI12 Mode Garland Technology 716 242 8500 garlandtechnol...

Страница 16: ...supports TAPA Mode when it is enabled incoming traffic in port NET0 is mirrored to both monitor ports and incoming traffic in port NET1 is mirrored to both monitor ports Figure 5 EdgeSafe Bypass TAPA...

Страница 17: ...incoming traffic in port NET0 is mirrored to both monitor ports and incoming traffic in port NET1 is mirrored to both monitor ports Packets can be injected from port MON0 to both network ports Figure...

Страница 18: ...ort NET1 is mirrored to both monitor ports Packets can be injected from port MON1 to both network ports Figure 7 EdgeSafe Bypass TAPAI2 Mode 2 11 TAPAI2 mode The IBS supports TAPAI12 Mode when it is e...

Страница 19: ...om each monitor port to both network ports Figure 8 EdgeSafe Bypass TAPAI12 Mode 2 12 Linkdrop mode In Linkdrop mode the IBS disables the links on the network ports NET0 NET1 The IBS simulates switch...

Страница 20: ...rts a two ports link feature When enabled if one of the network ports link fails it will drop the link on the other network port as well 2 14 Restore from active expire state The IBS supports manual a...

Страница 21: ...te When heartbeat active mode is set to OFF the IBS stops sending the heartbeats and the IBS can be set manually via the management port to one of the following modes Normal Inline Active Bypass TAP o...

Страница 22: ...t Passive Bypass circuitry watchdog timer expired 6 OFF indicate that Passive Bypass circuitry watchdog timer disabled 7 BLINK indicate that heartbeat pulse sent to Passive Bypass circuitry 8 Bypass m...

Страница 23: ...ity AC LED indicate network activity for monitor port 1 20 Monitor port 1 link LK LED indicate network link for monitor port 1 21 Normal mode NRM LED indicate when ON that Normal mode is set 22 Networ...

Страница 24: ...mware Rev Level 0 3 3 2 3 2 EdgeSafe IBS1U IBS1U with 4 modules Figure 11 EdgeSafe with 4 modules 3 3 IBSSU IBS standalone unit front panel Figure 12 EdgeSafe IBSSG front panel Garland Technology 716...

Страница 25: ...el 0 3 3 2 4 Rear Panels 4 1 EdgeSafe IBS1U IBS1U rear panel Figure 13 IBS1U rear panel 4 2 EdgeSafe IBSSU IBS standalone unit rear panel Figure 14 EdgeSafe IBSSG Stand alone unit rear panel Garland T...

Страница 26: ...supplies on to the back of the IBS The PWR led s on the front panel of the IBS will illuminate when switching on the power switch power 5 3 Connecting Power to the DC IBS unit 48VDC 5 3 1 Use DC powe...

Страница 27: ...the terminal window 7 The login name admin the default password gtadmin1 8 After login you should change password user and date If you plan to use management Ethernet port set IP address net mask and...

Страница 28: ...prompt after login The help command displays a list of all CLI commands The help full command displays help for all CLI commands The Command parameters can include any letter or number and _ characte...

Страница 29: ...show set_timezone show_daylight_status show_support_info show set_web_username set_web_password save_conf restore_conf show_list_conf remove_conf show set_tacacs_multi_users show set_tacacs_status se...

Страница 30: ...state When heartbeat active mode is set to OFF the IBS stops sending the heartbeats and the Active Bypass circuitry can be set manually via the management port to one of the following modes Normal In...

Страница 31: ...op In order to check the current mode of the Active bypass circuitry use the command show_bypass_mode In order to change set the Active bypass circuitry use the command set_bypass_mode Examples 6 5 Po...

Страница 32: ...are version 0 3 2 0 and up Example 6 6 hb_interval hb_interval The IBS generates a heartbeat packet to monitor PORT0 every hb_interval msec default 5 min 3 max 10000 The Heartbeat interval should be a...

Страница 33: ...lue should be at least 3 times the hb_interval parameter value default 20 min 10 max 50000 The hb_holdtime value is preserved after reset and power off events Example 6 8 Keep heartbeat active mode ke...

Страница 34: ...tate When the IBS does not receive the heartbeat packet within the hb_holdtime time it will set the Active Bypass circuitry to the state that was set by the hb_exp_state Bypass Tap Tapi12 Tapa Tapai1...

Страница 35: ...b_restore is ON the IBS will restore to Inline Normal state when the heartbeat packets will be received from the Monitor port When the en_act_hb_restore is OFF the IBS preserves its state and no heart...

Страница 36: ...6 11 Change Bypass state on RX TX error detection rx_tx_err_mode The IBS can place itself into Bypass or Linkdrop in case it detects RX TX errors on the Monitor ports or on the Network ports Example...

Страница 37: ...based on IP MPLS tag VLAN id It is possible to set the filter to specific value or the range by entering mask value For MLPS and IP it is possible to set the upstream net0 to Net1 or and downstream Ne...

Страница 38: ...USER GUIDE EdgeSafe 10G Modular Bypass Firmware Rev Level 0 3 3 2 Garland Technology 716 242 8500 garlandtechnology com support 38...

Страница 39: ...fault link speed is 1G Auto negotiation Please note that both Network and Monitor ports should use the same Network speed in order to avoid packet loss Example 6 13 1 Two port link The IBSG Copper and...

Страница 40: ...port if correspondent monitor port link gone This Mode can be set independent for each monitor port Example 6 13 3 M2M mode M2M monitor ports two port link When enabled on if one of the monitor ports...

Страница 41: ...ed link mode enables the IBS ability to detect Network and Monitor link failure based on RX disconnection on the link partner By default the advanced link is disabled off It is possible to change the...

Страница 42: ...a telnet SSH WEB or SNMP applications should be reconfigured to use new IP address 6 15 Ethernet management port net mask address The Ethernet management port default net mask address is 255 255 255 0...

Страница 43: ...different IP address using the command set_gateway Example Notes New gateway address will take effect only after performing device reboot Remote control via telnet SSH WEB or SNMP applications should...

Страница 44: ...are Rev Level 0 3 3 2 6 18 Time To change the IBS date and time use the command set_time mm DD HH MM YYYY Where mm month DD day HH hour 24 hours format MM minute YYYY year Example Garland Technology 7...

Страница 45: ...sername will take effect after the next login Example 6 20 Display current user Current user can be displayed by command show_current_user Example 6 21 System password set_psw To change the IBS system...

Страница 46: ...default unit name ibs using the command set_unit_name Unit name can be up to 25 symbols Example 6 23 Who am I whoami Blink the S OK LED on the currently controlled IBS unit in order to identify the re...

Страница 47: ...E EdgeSafe 10G Modular Bypass Firmware Rev Level 0 3 3 2 6 25 Display IBS parameters show_params Show the current IBS parameters values Example Garland Technology 716 242 8500 garlandtechnology com su...

Страница 48: ...ass Firmware Rev Level 0 3 3 2 6 26 Display IBS state show_dev_state Show the current IBS Bypass and operational mode state Note This command resets the Alarm LED Example Garland Technology 716 242 85...

Страница 49: ...splay device hardware version show_hw_ver Example 6 28 Display device firmware version show_fw_ver Device firmware version is the generalized version that allows you to determine versions of all softw...

Страница 50: ...ion is 0 1 0 0 or higher Example For the IBSG10 For the IBSG 1G Copper and 1G Fiber 6 32 Displaying power supplies states The command show_power_state displays the status of the 1U chassis power suppl...

Страница 51: ...e IBS receives the heartbeat packets Fail The link on the monitor ports are ON and the IBS does not receive the heartbeat packets Unknown The link on the monitor ports are OFF Example 6 34 Display rs2...

Страница 52: ...t port auto negotiation status The command set_link XXX enable_autoneg disable_autoneg is used to set Ethernet port auto negotiation mode By default auto negotiation is enabled This command is support...

Страница 53: ...reboot or power off The log file is saved in 2 x 4096KB cyclic blocks When two blocks are full the older block is cleared and the new information is written in the location of the old block Example E...

Страница 54: ...ldtime 20 ms hb_tx_dir mon0 hb_fail unidir enable snmp traps disabled all snmp trap snmp server ip 192 168 0 6 snmp version 1 WEB expired time 900 sec WEB https disabled TFTP server ip 192 168 0 6 SNM...

Страница 55: ...server IP 192 168 0 6 NTP server IP 192 168 0 6 Timezone UTC Tacacs state off Tacacs server IP 192 168 0 6 Tacacs fallback off Tacacs multi users off WEB user name admin WEB user password gtadmin1 Tac...

Страница 56: ...h_to_fw_update force NOTE If the firmware update process is interrupted your IBS may not function properly We recommend the process be done in an environment with a steady power supply preferably with...

Страница 57: ...s certificate By default the IBS Factory certificate can be used to encrypt the connection To replace the certificate with one that is signed by your own CA use the command set_cert set_cert tftp_serv...

Страница 58: ...ault 900 sec In case that the WEB session was terminated the Login screen will appear on the WEB browser Example 6 48 Show Set Ethernet management port status mgmt_port_state The IBS Ethernet manageme...

Страница 59: ...6 49 Show Set Ethernet management port parameters mgmt_port_params The IBS Ethernet management port can set to auto negotiation mode or to force 10 Mbit s half duplex mode factory default auto Example...

Страница 60: ...p new_state new_state on off trap appl application state change trap bp bypass state change trap mon monitor ports state change trap net network ports state change trap term terminal port state change...

Страница 61: ...USER GUIDE EdgeSafe 10G Modular Bypass Firmware Rev Level 0 3 3 2 Garland Technology 716 242 8500 garlandtechnology com support 61...

Страница 62: ...ket length 24 1024 bytes Destination MAC XX XX XX XX XX XX This value will be replaced by the IBS to the IBS port0 port1 MAC address Source MAC XX XX XX XX XX XX This value will be replaced bythe IBS...

Страница 63: ...t content can be restored by command 6 51 4 Show Set heartbeat packet transmit direction Heartbeat packets can be transmitted from either MON0 or MON1 or from both ports By default the heartbeat packe...

Страница 64: ...he hb_holdtime time it will set the Active Bypass circuitry to the state that was set by the hb_exp_state Bypass Tap or linkdrop mode While the heartbeat packets transmit direction is set to Bidirecti...

Страница 65: ...log state can be retrieved by command show_remote_log_state Example 6 52 2 Set remote log state The IBS remote log state can be set by command set_remote_log_state Example 6 52 3 SHOW remote log serve...

Страница 66: ...3 1 SHOW NTP state The IBS NTP state can be retrieved by command show_ntp_state 6 53 2 Set NTP state The IBS NTP can be enabled or disabled by command set_NTP_state 6 53 3 SHOW NTP server IP The NTP s...

Страница 67: ...Firmware Rev Level 0 3 3 2 6 53 5 Add NTP server IP Add NTP server IP 6 53 6 Delete NTP server IP 6 53 7 Send NTP request Force NTP request using the command send_ntp_request Garland Technology 716 24...

Страница 68: ...Command show_timezone_list displays the supported time zones The Time zones are united to groups The Command timezone can retrieve time zone group names all time zones in group all time zones or all t...

Страница 69: ...current time zone Default time zone is UTC GMT 0 time zone 6 54 3 Set timezone Several time zones supported daylight saving changes When setting time zone the daylight saving mode can be disabled or...

Страница 70: ...fe 10G Modular Bypass Firmware Rev Level 0 3 3 2 6 54 4 SHOW daylight saving state Daylight saving state can be retrieved by command show_daylight_state Garland Technology 716 242 8500 garlandtechnolo...

Страница 71: ...Level 0 3 3 2 6 55 SHOW technical support information The command gathers all the necessary information needed for the Technical Support team in order to help resolve technical problems Garland Techn...

Страница 72: ...USER GUIDE EdgeSafe 10G Modular Bypass Firmware Rev Level 0 3 3 2 Garland Technology 716 242 8500 garlandtechnology com support 72...

Страница 73: ...th can be from 8 to 60 characters 6 56 1 SHOW WEB user name WEB user name can be retrieved by command show_web_user 6 56 2 Set WEB user name WEB user name can be set by command set_web_user 6 56 3 Set...

Страница 74: ...6 57 1 Display saved IBS configurations Command show_list_conf used for displaying the local saved IBS configurations 6 57 2 Save IBS configuration Command save_conf used for local and remote saving t...

Страница 75: ...The IBS supports the Telnet protocol By default the Telnet access is enabled The Command show_telnet_state is used to retrieve telnet access state The Command set_telnet_state is used to enable or di...

Страница 76: ...9 SSH access The IBS supports SSH protocol By default the SSH access is enabled The Command show_ssh_state is used to retrieve ssh access The Command set_ssh_state is used to enable or disable ssh acc...

Страница 77: ...xPktGood snmpEtherStatsRXNoErrors RFC 1757 5 RxUnicastPkts snmpIfInUcastPkts RFC 1213 6 RxMulticastPkts snmpEtherStatsMulticastPkts RFC 1757 7 RxBroadcastPkts snmpEtherStatsBroadcastPkts RFC 1757 8 Tx...

Страница 78: ...t secret key default_tac_key Support Multi TACACS servers default TACACS server IP 192 168 0 6 By default the Serial port access TACACS support is disabled By default there is no login fallback when t...

Страница 79: ...0 servers additional TACACS server can be added to the TACACS servers using the command add_tacacs_server_ip 6 61 4 Del TACACS server IP TACACS server IP can be deleted from the TACACS server list usi...

Страница 80: ...6 Set RS232 TACACS login By default there is no TACACS server login validate for RS232 access The command set_rs232_tacacs_login enable disable the TACACS login validation for RS232 access 6 61 7 SHOW...

Страница 81: ...IBS only via the Serial port The command set_tacacs_login_fallback enables disables the login fallback to the local IBS credentials in case that no TACACS server is available 6 61 9 SHOW TACACS login...

Страница 82: ...sers flag can be displayed by command show_tacacs_multi_users 6 61 13 TACACS authorization When TACACS authorization is enabled the IBS uses information retrieved from the user profile which is locate...

Страница 83: ...only if NetIP IP NetMask Maximum number of permitted IP ranges 20 6 62 1 Set delete permitted IP range New permitted IP range can be added by command set_ mgmt_permit_ip Permitted IP range can be rem...

Страница 84: ...ly with Trap read write with Trap and different SNMP version 1 2c and 3 SHA and AES and SNMP discovery 7 1 SNMP_Entry commands There are 4 different commands which enable the option to view select add...

Страница 85: ...USER GUIDE EdgeSafe 10G Modular Bypass Firmware Rev Level 0 3 3 2 7 1 1 add_snmp_entry Add new SNMP entry up to 11 different entries Garland Technology 716 242 8500 garlandtechnology com support 85...

Страница 86: ...elect SNMP entry sel_snmp_entry In order to modify the SNMP entry select the entry from the list of current active entries which showed by the show_snmp_entry sel_snmp_entry entry_index select snmp en...

Страница 87: ...R GUIDE EdgeSafe 10G Modular Bypass Firmware Rev Level 0 3 3 2 7 1 3 Set show_snmp_user set_snmp_user XXX set snmp user name 5 30 symbols Garland Technology 716 242 8500 garlandtechnology com support...

Страница 88: ...IDE EdgeSafe 10G Modular Bypass Firmware Rev Level 0 3 3 2 7 1 4 snmp version set_snmp_ver XXX set snmp version 1 2c 3 default 1 show_snmp_ver Garland Technology 716 242 8500 garlandtechnology com sup...

Страница 89: ...MP servers IP show_snmp_srv_ip show the SNMP servers IP for the current selected entry add_snmp_srv_ip add SNMP server IP to the current selected entry del_snmp_srv_ip delete SNMP server IP from the c...

Страница 90: ...USER GUIDE EdgeSafe 10G Modular Bypass Firmware Rev Level 0 3 3 2 7 1 5 2 add_snmp_srv_ip Garland Technology 716 242 8500 garlandtechnology com support 90...

Страница 91: ...USER GUIDE EdgeSafe 10G Modular Bypass Firmware Rev Level 0 3 3 2 7 1 5 3 del_snmp_srv_ip Note The main SNMP srv_ip cannot be deleted Garland Technology 716 242 8500 garlandtechnology com support 91...

Страница 92: ...mware Rev Level 0 3 3 2 7 1 5 4 set_snmp_srv_ip modify the IP address of the main SNMP server set_snmp_srv_ip xxx xxx xxx xxx set MAIN snmp server ip address default 192 168 0 6 Garland Technology 716...

Страница 93: ...how set_snmp_access Each entry supports different levels of access read only read write trap only read only with Trap set_snmp_access access set snmp community access read read_write trap read_trap re...

Страница 94: ...rypt and decrypt the SNMP information set_snmp_user_psw set_snmp_user_psw OLD NEW set snmp user password 8 60 symbols 7 1 8 snmp community status show set_snmp_status The snmp_comunity_status activate...

Страница 95: ...tap IP port set_snmp_trap_port XXX set snmp trap port min 1 max 49151 default 162 show_snmp_trap_port 7 1 2 SNMP MSG IP port show set_snmp_msg_port Control the SNMP msg IP port set_snmp_msg_port XXX...

Страница 96: ...evice Fan status ibsLogLastLine 1 14 INTEGER read only Show log file last line number ibsLogReadLine 1 15 INTEGER read write Show set log file line number to read from ibsShowLog 1 16 OCTET STRING SIZ...

Страница 97: ...emoteLogServerIp 3 17 IP Address read write Set Show remote log server IP address NOTE next SNMP command should be send not before 1 sec after this command ibsSysNTP 3 18 INTEGER read write on 1 off 2...

Страница 98: ...password separated by semicolon 192 168 0 0 community1 gt82d7yfr 193 151 0 0 community2 Take effect after setting ibsSnmpApply ibsSysRemoveTrapAccount 3 40 OCTET STRING SIZE 9 2550 read write Remove o...

Страница 99: ...n0 or mon1 the ibsConfHbFail must be set to unidir ibsConfDefHbPkt 4 14 INTEGER read write default 1 Restore default heartbeat packet content Set only the variable read will return zero ibsConfMgmtPor...

Страница 100: ...Up ibsTrapConfNetLink 7 5 INTEGER read write enable 1 disable 2 Enable Disable SHOWting trap info on Network ports Link status change events ibs TrapNet0LinkDown ibs TrapNet0LinkUp ibs TrapNet1LinkDow...

Страница 101: ...ocal serial RS232 connection is disconnected ibsTrapTermCon 17 Trap is sent when local serial RS232 connection is connected ibsTrapErr 18 Trap is sent as indication of an error within the IBS with som...

Страница 102: ...function ibsTrapNet1Enable2pl 36 This trap is sent when network port 1 was enable by 2pl function ibsTrapNet0Disable2plM2n 37 This trap is sent when network port 0 was disable by 2pl m2n function ibsT...

Страница 103: ...l authPriv a SHA A gtadmin1 x AES X gtadmin1 192 168 0 100 GARLAND IBS MIB ibs TrapConfTerm 0 SNMP v3 set request snmpset v 3 u admin l authPriv a SHA A gtadmin1 x AES X gtadmin1 192 168 0 100 GARLAND...

Страница 104: ...WEB interface will take effect only after clicking the apply button 8 2 Login On the login screen type the user name and the password Default username is admin Default password is gtadmin1 Usernames...

Страница 105: ...USER GUIDE EdgeSafe 10G Modular Bypass Firmware Rev Level 0 3 3 2 8 3 Information Page Garland Technology 716 242 8500 garlandtechnology com support 105...

Страница 106: ...ult 900 sec 8 3 3 Information area description The WEB interface includes five Information areas Device info Link info Error info Status info Statistics The Information area includes read only informa...

Страница 107: ...linkdrop Passive state bypass inline Application state alive fail unknown Power supply 1 and 2 status only for hardware 0 3 0 11 and up Box Fan status 1 6 only for hardware 0 3 0 11 and up 8 3 3 5 St...

Страница 108: ...the monitor ports the IBS will switch to Active Bypass or TAP TAPI12 TAPA TAPAI1 TAPAI2 TAPAI12 or Linkdrop mode according to the predefined settings of the HB active expire select box When heartbeat...

Страница 109: ...t box to one of the following modes Normal Inline Active Bypass TAP TAPI12 TAPA TAPAI1 TAPAI2 TAPAI12 or Linkdrop mode 8 4 1 5 HB active expire select box When heartbeat active mode is ON the IBS send...

Страница 110: ...ration area 8 4 3 1 2 port link The IBS supports two ports When enabled on if one of the network ports link fails it drop the link on the other network port Two ports link is disabled off by default 8...

Страница 111: ...t link When enabled on if one of the monitor ports link fails it drops the link on the other monitor port M2M k is disabled off by default 8 4 4 RX TX errors processing The IBS can place itself into B...

Страница 112: ...linkdrop when number of errors per second on MONx ports exceeds threshold 8 4 4 4 Net Change the Bypass mode to none linkdrop when number of errors per second on NETx ports exceeds threshold 8 4 4 4...

Страница 113: ...ports or on the Network ports 8 5 1 1 Unit name The IBS supports individual name for each IBS unit on the network The User can set the IBS unit name default unit name ibs Unit name can be up to 25 sym...

Страница 114: ...lt IP 192 168 0 6 8 5 2 3 TACACS mode TACACS mode allow to view add and remove additional TACAS server up to 10 TACACS servers and to set the main TACACS server 8 5 2 4 TACACS secret key Set the TACAC...

Страница 115: ...one state Set the time zone Select from dropdown menu default UTS 8 5 4 NTP configuration area The IBS clock can be synchronized from the NTP server on the network The IBS support Multi NTP servers 8...

Страница 116: ...WEB or SNMP applications should be reconfigured to use new gateway IP addresses 8 5 5 4 Permitted Network IP list There are two fields which controls the permitted IP address 1 Operations 2 Permitted...

Страница 117: ...ll be terminated by the IBS default 900 sec In case that the WEB session is terminated the Login screen will appear on the WEB browser If the main WEB interface window will be closed in any way other...

Страница 118: ...only read Only with Trap read write with Trap and different SNMP version 1 2c and 3 SHA and AES and SNMP discovery 8 7 1 1 SNMP server IP address Using the IP operation select box and the current IP i...

Страница 119: ...ol SNMP trap control destined to enable disable SNMP trap groups SNMP traps are disabled by default It can be enabled by checking the check box for the relevant trap group 1 Appl fail enable disable f...

Страница 120: ...le disable following traps a ibs TrapTermDisc b ibs TrapTermCon 7 Error enable disable following traps a ibs TrapErr b ibsTrapPower1OK only for hardware 0 3 0 11 and up c ibsTrapPower1OK only for hard...

Страница 121: ...y default disable The Remote log should be enabled on the remote server to receive messages from the device 8 8 1 1 Reset log file Reset the log file erase the content of the log 8 8 1 2 Remote log Se...

Страница 122: ...eSafe 10G Modular Bypass Firmware Rev Level 0 3 3 2 8 9 HB Packet page This page enables the user to change or to load new Heartbeat packet content Garland Technology 716 242 8500 garlandtechnology co...

Страница 123: ...USER GUIDE EdgeSafe 10G Modular Bypass Firmware Rev Level 0 3 3 2 8 10 Rescue page Garland Technology 716 242 8500 garlandtechnology com support 123...

Страница 124: ...re the factory default settings for all parameters including system user name and password 8 10 2 2 Reset errors Reset the IBS errors The IBS displays on the LCD the first error only after resetting t...

Страница 125: ...Rev Level 0 3 3 2 8 10 3 Technical support area The command gathers all the necessary information needed for the Technical Support team in order to help resolve technical problems Garland Technology...

Страница 126: ...g queries INFO INFOMNF OP EXIT Use a short press on the PB0 button in order to move to the next submenu Use a short press on the PB1 button to enter to the submenu 9 2 INFO menu The INFO MNF menu incl...

Страница 127: ...the PB1 button to select the query and to display the next data item on the query 9 2 OP menu The INFO MNF menu includes the following queries SHUTDOWN Shutdown the IBS module the module will reload...

Страница 128: ...rts up to four modules in a chassis Supports 6 different TAP mode of operation Simple CLI configuration management via serial port HTTP HTTPS management interface via network management port Telnet ma...

Страница 129: ...does not respond heartbeat Bypass Tap Linkdrop Mode at Power 0ff Bypass Heartbeat Packet Internetwork Packet Exchange 10 4 Technical specifications 10 4 1 IBSH 10 4 1 1 IBS1U IBS1UP Bypass Switch 1U H...

Страница 130: ...B Insertion Loss Passive Bypass Mode Typical 0 8 dB Maximum 1 9 dB Voltage 12V Power Consumption 25W max Operating Humidity 0 90 non condensing Operating Temperature 0 C 40 C 32 F 104 F Storage Temper...

Страница 131: ...ion 25W max Operating Humidity 0 90 non condensing Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 20 C 65 C 4 F 149 F EMC Certifications Class B FCC CE VCCI Safety UL 10 4 3 2 LED and C...

Страница 132: ...3mm x 164 9mm x 20 mm 6 822 x 6 73 x 0 787 Wide x Depth X Height Operating Humidity 0 90 non condensing Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 20 C 65 C 4 F 149 F EMC Certificat...

Страница 133: ...x 0 787 Operating Humidity 0 90 non condensing Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 20 C 65 C 4 F 149 F EMC Certifications Class B FCC CE VCCI Safety UL MTBF 150 000 hours 1...

Страница 134: ...1U 1U 1UP 1U unit with power supply trap capabilities 1G 1Gb 1GP 10Gb with power supply trap capabilities SR 10G Short Range SX 1G Short Range US EU CN 48V ROHS 10G 10Gb LR 10G Long Reach 10GP 10Gb w...

Страница 135: ...ss Switch 1U host system 1U host system 90 240 VAC Auto Select EU cable IBS1UP EU Intelligent Bypass Switch 1U host system 1U host system 90 240 VAC Auto Select EU cable with power supply trap capabil...

Страница 136: ...work ports SR on the Monitor ports 1U host US cable IBS10G1UP 2SR EU 1U w Two 10 Gigabit SR Intelligent Bypass Switch 2 x Multimode fiber 62 5um 1U host EU cable IBS10G1UP 2SR 48 1U w Two 10 Gigabit S...

Страница 137: ...y considerations for the IBS rack mounting A Verify that the maximum operating ambient temperature inside a rack assembly does not exceed 50C B Verify that a sufficient clear space is provided around...

Страница 138: ...omputer from the Internet 4 Turn off the firewall Run the following command iptables F or type setup 5 Create the tftboot directory mkdir tftpboot 6 For FC4 edit file etc sysconfig selinux SELINUX PER...

Страница 139: ...INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Networks Associates Technology Inc copyright notice BSD Copyright...

Отзывы: