background image

35 

CORRESPON-

DING DTMF 

CHARACTER 

COMMANDS 

ITEM 

COMMAND 

EXAMPLE & USAGE 

DEFAULT

46# 

Follow-on & 

two-way 

period 

FOLTI 

PROG 1111 FOLTI:02 
To set the duration for follow-on & two-way voice 
communication period 
01-10=1-10 minutes 

02 =  

2 minutes

47# Off-set 

time 

OFFST 

PROG 1111 OFFST:1 
To set the off-set time 
1=1 Hour, 2=2 Hours, 3=3 Hours 
4=4 Hours, 5=8 Hours, 6=12 Hours 

1 =  

1 Hour 

49# Supervision 

SUPPR 

PROG 1111 SUPPR:0 
To set the supervision timer 
0=Disable, 1=4 Days, 2=5 Days, 3=6 Days 
4=7 Days, 5=8 Days, 6=9 Days, 7=10 Days 

0 = Disable

61# 

Check SIM 

card Pin 

code 

SIMPE 

PROG 1111 SIMPE:0 
To set Check SIM Card Pin Code 
0 = Disable , 1 = Enable 

0 = Disable

62# 

Input SIM 

card Pin 

code 

SIMPC 

PROG 1111 SIMPC:0000 
PROG 1111 SIMPC:12345678 
To input SIM CARD Pin Code: 4~8 digits are allowed to be 
entered.  

Null 

 

Talk Only 

Spk volume: 

63# 

Set speaker 

volume 

SPKVL 

PROG 1111 SPKVL:1&1~15 
PROG 1111 SPKVL:2&1~15 

¾

 

To set a communication channel: 1=Talk only, 2=Two 
Way  

¾

 

To set the speaker volume with a number, ranging 
1~15.The higher the value, the louder the voice.  
Default is set as (9) for talk only mode and set as (3) for 
two-way mode.   

Two way 

Speak Vol.:3 

64# 

Set 

microphone 

sensitivity 

MICSN 

PROG 1111 MICSN:1~9 

¾

 

To set the microphone volume with a number, ranging 
1~9. The higher the value, the wider range the  

sound received. Default is set as (4).  
Note: only can be adjusted in the two-way mode.  

 

Mic: 4 

 

--- 

Country 

code 

REPLA

 

PROG 1111 

REPLA

:886&0 

To replace the Country Code with 0 
886 

Æ

 Country Code 

No country 

code 

--- IP 

address 

TCIP1 

PROG 1111 TCIP1:192.168.1.110 
To set/change the IP address for the Monitoring Station 
Input IP address: 000.000.000.000 to 255.255.255.255 

No IP 

address

--- IP 

address 

TCIP2 

PROG 1111 TCIP2:192.168.1.110 
To set/change the IP address for the Monitoring Station 
Input IP address: 000.000.000.000 to 255.255.255.255 

No IP 

address

--- 

IP address 

confirm 

COMIP 

PROG 1111 COMIP:192.168.1.110 (for confirmation) 
To set/change the IP address for the Monitoring Station 
Input IP address: 000.000.000.000 to 255.255.255.255 

No IP 

address

--- 

Port 

number 

PORT1 

PROG 1111  PORT1:3301 
To set/change the port number for the IP address 
Input 1 to 5 digits 

No port 

number

--- 

Port 

number 

PORT2 

PROG 1111  PORT2:3301 
To set/change the port number for the IP address 
Input 1 to 5 digits 

No port 

number

--- 

Port 

number 
confirm 

COMPO 

PROG 1111  COMPO:3301 (for confirmation) 
To set/change the port number for the IP address 
Input 1 to 5 digits 

No port 

number

--- 

GPRS/IP 

account 

number 

IPAC1 

PROG 1111 IPAC1:1052 
To set/change the GPRS/IP account number (4-10digit) 

No 

account 

number

--- 

GPRS/IP 

account 

number 

IPAC2 

PROG 1111 IPAC2:1052 
To set/change the GPRS/IP account number (4-10digit) 

No 

account 

number

--- 

Access 

Point Name 

APNSR 

PROG 1111 APNSR:INTERNET 
To set/change the Access Point Name (APN server) 

No APN

--- User 

name 

GPUSE 

PROG 1111 GPUSE:123 
To set/change the user name 
Input 1 to 15 alphanumeric characters 

No user 

name 

Содержание CTC-1052RV

Страница 1: ...E1 MAR 30 2011...

Страница 2: ...____________________________________ 6 3 2 Programming Your 1052_________________________________________________________ 6 3 3 SMS Remote Programming _________________________________________________...

Страница 3: ...________________________________________________________ 28 5 2 Tunstall Event Code____________________________________________________________ 28 5 3 Scancom Event Code ______________________________...

Страница 4: ...mergency call See section 4 1 2 Press hold for 6 sec enter Learning Mode Press hold for 16 sec disable mobility setting RED HELP BUTTON with backlight Back lit disigned for easy access at night Backli...

Страница 5: ...ery used is a Ni Cd 7 2V 1600 mAH rechargeable battery z During normal operation the AC power adapter is used to supply power to CTC 1052RV and at the same time recharge the battery z When the battery...

Страница 6: ...aced close to any heat source such as microwave ovens which can reduce signal strength z The Control Panel should not be located alongside other radio transmitting devices such as mobile phones cordle...

Страница 7: ...RESET button of CTC 1052RV for 6 seconds Release the button after you heard the double beep After releasing the button a long beep will be heard The RED LED begins to flash to indicate that the CTC 10...

Страница 8: ...red down when in Programming Mode When AC Power resumes or when exits from Programming Mode GPRS GSM will be powered on again 3 1 1 Local Programming Mode Optional From Idle mode follow the steps belo...

Страница 9: ...2 digit DTMF Command 2 Termination of the DTMF Command 3 ACK DTMF Command Acknowledgement On CTC 1052RV Short beep Command succeeded Long beep Command failed On the programming phone set Short beep C...

Страница 10: ...mmand 05 06 Select Telephone Number for Alarm Reporting and Status Reporting I IM MP PO OR RT TA AN NT T N NO OT TE E If the Tel number is selected in Commands 5 6 and 7 then Command 7 holds the top p...

Страница 11: ...election Sequence Disable 0 1st Tel 1 2nd Tel 2 3rd Tel 3 4th Tel 4 z Factory default is set as 0 disable Non emergency call will be reported to all of 4 Telephone Numbers z Please refer to section 4...

Страница 12: ...er accordingly If any of SMS Reporting Methods is selected CID sent over SMS is a backup path when alarm can t go through in digital reporting method Once alarm or emergency data is successfully trans...

Страница 13: ...he GREEN RESET BUTTON is not pressed within 15 minutes CTC 1052RV will send one more Help Call report to summon help and inform the Monitoring Center that no help has arrived within the past 15 minute...

Страница 14: ...onnel should enter an authorized access code default 1111 followed by to set up the two way communication between CTC 1052RV and the Monitoring Center If the alarm is triggered by a Talking Pendant WT...

Страница 15: ...nt reporting to 99 seconds z During this time period a continuous series of beeps will be emitted to alert user z If a false alarm is triggered it can be cancelled within the Guard Time Delay Function...

Страница 16: ...unication immediately according to the setting under this command Function Selection Result 0 WAIT COMMAND 1 LISTEN 2 TWO WAY z Factory Default is set as 2 TWO WAY N NO OT TE E When 0 is selected afte...

Страница 17: ...3 Hour 4 4 Hour 5 8 Hour 6 12Hour z Factory default is set as 1 1 Hour When the Off Set Time is reset in programming Mode the time of the Off Set period will recalculate z Off Set time Report will be...

Страница 18: ...ard PIN Code set by Command 62 If the SIM card PIN Code is entered be sure to enable this function Otherwise the SIM card will be locked Command 62 Input SIM Card PIN Code z This function is used to i...

Страница 19: ...er range of sound source Factory default is set as 4 z Please refer to programming command table p 34 for configuration N NO OT TE E The volume in the Listen mode is set as maximum and can not be chan...

Страница 20: ...ceived within 20 sec CTC 1052RV will emit a long beep and automatically returns to Programming mode Step 3 CTC 1052RV will emit 2 beeps to indicate that Pendant 2 is learnt in successfully Adding a Pe...

Страница 21: ...to indicate the device is learnt in successfully Adding a Pendant for a second time is prohibited unless it is removed from the system first If one long beep is emitted instead of 2 beeps it indicate...

Страница 22: ...Pendant Button or the RED HELP BUTTON on CTC 1052RV z User can also remotely answer the call by pressing the Pendant Button on the Talking Pendant WTRV z Once CTC 1052RV answers the call it will open...

Страница 23: ...tarts to flash as a visual warning to the user GSM will be then be powered down Thus Remote Programming is unavailable GSM will be powered up only at times of reporting z Once the AC Power resumes the...

Страница 24: ...Please use Command 44 to enable the Mobility timer again 4 1 8 No Pendant Present z This function is only available for the digital Contact ID reporting method z If there is no pendent being learnt in...

Страница 25: ...out to inform you that the call is in progress regardlss of Digital or Speech Reporting Method z Confirmation beeps will be heard in the following situations After CTC 1052RV dials out to summom help...

Страница 26: ...llow On and or Call Back mode zCall Back Operation z If Command 38 is set as Call Back 1 or Follow On Call Back 2 after alarm is reported to CMS the system will then wait 5 mins for Monitoring Center...

Страница 27: ...o Microphone Sensitivity Control and then press 6 or 4 to increase or decrease the levels of microphone sensitivity in the Two Way communication mode Press any DTMF key except the designed hang up key...

Страница 28: ...phone are adjusted in the two way or talk only communication mode please note that these two levels will return to preset values after ending a call z The allowable time duration for Follow On Period...

Страница 29: ...omatically If both Digital and Speech Alarm reporting are set the reporting call sequence will only be terminated once one Digital reporting any of CID Scancom or Tunstall protocols and one Speech rep...

Страница 30: ...5 Global Test z Global Test is used to test if the complete system is working properly To do the Global Test Step 1 Press the RESET button once Step 2 Within 5 secs press Pendant button Step 3 CTC 105...

Страница 31: ...under Low Battery Status Green LED flashes every 2 secs with 2 beeps z 384 Other devices Low Battery When other devices are under Low Battery Status Green LED flashes every 2 secs with 2 beeps wheneve...

Страница 32: ...30 secs z 555553557 AC Failure Restore When AC power fails for more than 10 sec Green LED flashes every sec with a beep every 30 secs z 515555559 Global test Auto check in report When the CTC 1052RV r...

Страница 33: ...R Low battery Restore When the Low Battery status of PIR Motion Detector IR is restored FCC Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two condi...

Страница 34: ...ll formats the same 0 Contact ID 1 Scancom 2 Tunstall 3 Voice 4 SMS CID Bi Contact ID 21 Bi 0 Contact ID 1 Scancom 2 Tunstall 3 Speech 4 SMS CID Tel Number 1 Bi Contact ID 22 Bi 0 Contact ID 1 Scancom...

Страница 35: ...0 extended 900E 1900MHz Europe U S Bi Mono band mode 1900 MHz U S 61 Bi Check SIM CARD PIN CODE 0 Disable 1 Enable Bi Disable 62 Bi Set Input SIM CARD PIN CODE 4 8 digital Bi Null Talk only mode Speak...

Страница 36: ...hone 1 2 Telephone 2 3 Telephone 3 4 Telephone 4 5 GPRS1 6 GPRS2 1 2 3 4 5 06 Telephone number for status report STARP PROG 1111 STARP 1234 To select then number for status report 1 Telephone 1 2 Tele...

Страница 37: ...OG 1111 FAUTA 0 To enable disable audible fault alert 0 Disable 1 Enable 0 Disable 33 Help arrived signalling HELPA PROG 1111 HELPA 0 To enable disable help arrived signalling 0 Disable 1 Enable 0 Dis...

Страница 38: ...ed in the two way mode Mic 4 Country code REPLA PROG 1111 REPLA 886 0 To replace the Country Code with 0 886 Country Code No country code IP address TCIP1 PROG 1111 TCIP1 192 168 1 110 To set change t...

Страница 39: ...ed 3 When setting IP Address Confirm COMIP and Port Number confirm COMPO commands together the confirmation will send to assigned IP address However if COMIP and COMPO are set respectively or one of t...