ANCILLARY PARTS
PAGE 82
FUNCTIONAL TESTING
Once installed in service. Valves should be tested at least once every six months to ensure free movement
of parts. This should be carried out by operating the easing gear when the valve is under a pressure of not
less than 75'% of the set pressure. Where valves are supplied without easing gear, the test should be in
accordance with the full functional test described overleaf. Due regard must be paid to the safety personnel.
Testing should not create a hazard, particular attention being given to foreign matter located in discharge
outlets.
CONFIGURATION
The valves have a base number for different type valve arrangement from this information the valve set
pressure can be obtained, examples:-
98650.2073 is the base unit number.
98650.2073-16.2
-16.2 being to the setting in bar g - wire locked.
98650.2073-96.25
-96.25 being to the setting in bar g - wire locked.
98650.1164 is the base unit number.
98650.1164-28
-28 being to the setting in bar g - wire locked.
98650.1163 is the base unit number.
98650.1163-7.6
-7.6 being to the setting in bar g - wire locked.
98650.1020 is the base unit number.
98650.1020-3.8T
-3.8 being to the setting in bar g - wire locked and tagged.
98650.1021 is the base unit number.
98650.1021-9.6
-9.6 being to the setting in bar g - wire locked.
98650.1022 is the base unit number.
98650.1022-90T
-90 being to the setting in bar g - wire locked and tagged.
Note the valves cannot be interchanged as the range of setting is limited
Содержание Reavell H5000 Series
Страница 2: ......
Страница 18: ...SAFETY PAGE 16...
Страница 20: ...AMENDMENTS PAGE 18...
Страница 22: ...COMPRESSOR LOG SHEET PAGE 20 REMARKS DATE REMARKS DATE...
Страница 24: ...GENERAL DESCRIPTION AND OPERATION PAGE 22 4 6 LUBRICATION SCHEMATIC FLOW DIAGRAM...
Страница 26: ...GENERAL DESCRIPTION AND OPERATION PAGE 24...
Страница 36: ...OPERATION AND ROUTINE MAINTENANCE PAGE 34...
Страница 44: ...DISMANTLING AND REASSEMBLY OF VALVES PAGE 42...
Страница 50: ...FAULT GUIDE PAGE 48...
Страница 68: ...PARTS LIST PAGE 66 80 89 EXTERNAL COMPONENTS 83 4 84 1 83 5 83 6 83 3 83 2 83 1 4 2 81 1 3 4 82 4 2 1 3 4...
Страница 72: ...PARTS LIST PAGE 70 93 95 1ST STAGE CONCENTRIC VALVE 9 8 6 5 4 2 1 3...
Страница 74: ...PARTS LIST PAGE 72 96 97 2ND STAGE CONCENTRIC VALVE 2 1 3 4 5 6 5...
Страница 80: ...PARTS LIST PAGE 78...
Страница 92: ...ANCILLARY PARTS PAGE 90...
Страница 94: ...STANDARD WIRING TERMINAL NUMBERS PAGE 92...
Страница 95: ......