SAFETY
PAGE 7
1.2 FOREWORD
The
STANDARD
build of all
Reavell
products are not intended for use in either Explosive or Potentially
Explosive Atmospheres as defined in Directive 94/9/EC.
An Explosive atmosphere is a mixture with air, under atmospheric conditions, of flammable gases,
vapours, hazes or dusts in which, after ignition has occurred, combination propagates to the entire
unburned mixture and may cause a hazard.
A Potential Explosive atmosphere is an atmosphere, which could become explosive due to local
conditions.
Reavell
H5000 Series compressors are designed and manufactured to give optimum performance and
safety, together with long life and reliability whilst compressing the gas for which they have been
designed.
They
must not
be used to compress other gases without prior consultation with the
Reavell
factory.
This Manual will help you to obtain the best performance from your compressor. It provides the
information required for safe installation, commissioning and operation, together with a maintenance
schedule to ensure maximum service life.
Servicing facilities and the supply of genuine replacement parts are provided through a world-wide
network of Gardner Denver companies and authorised distributors, backed by the Reavell factory.
The information in this Manual was correct at the time of printing, but modifications to parts and
procedures may be made without notice which could affect the servicing requirements of the compressor.
In any communication concerning the compressor it is necessary to quote the the MODEL, SERIAL No.
and CONTRACT reference in order that the correct information is supplied.
It is important that this Manual is retained with the compressor for reference and that it should remain
with the compressor if it is sold or transferred to another user. The new user must be made fully aware of
the need to study this Safety Section and any Warnings for safe operation given throughout the manual.
1.3 MAINTENANCE
Before any servicing or maintenance work is undertaken, the user is advised to contact the local Gardner
Denver Company or authorised Distributor for revised or up-dated information.
To ensure continued trouble free operation of the compressor it is important that periodic maintenance
and servicing are carried out in accordance with the information given in the "Maintenance" section of this
Manual. If any replacement or repair is needed use genuine Reavell parts.
Any unauthorised modifications or failure to maintain this equipment in accordance with maintenance
instructions may make it unsafe.
The use of replacement parts not supplied by Reavell may create
hazardous conditions over which Reavell has no control.
Such hazardous conditions may lead to accidents that can be life threatening, cause substantial bodily
injury or result in damage to the equipment.
Reavell can bear no responsibility for equipment for
which unapproved replacement parts are included.
WARNING
The use of replacement parts or lubricating oils not supplied or approved by Reavell may lead to
failures in service which would not be covered by warranty.
1.4 WARRANTY
Conditions of the Reavell warranty are stated in our Standard Conditions of Sale. Details of warranty for
a particular contract may be obtained from the local Gardner Denver Company or authorised Distributor.
Содержание Reavell H5000 Series
Страница 2: ......
Страница 18: ...SAFETY PAGE 16...
Страница 20: ...AMENDMENTS PAGE 18...
Страница 22: ...COMPRESSOR LOG SHEET PAGE 20 REMARKS DATE REMARKS DATE...
Страница 24: ...GENERAL DESCRIPTION AND OPERATION PAGE 22 4 6 LUBRICATION SCHEMATIC FLOW DIAGRAM...
Страница 26: ...GENERAL DESCRIPTION AND OPERATION PAGE 24...
Страница 36: ...OPERATION AND ROUTINE MAINTENANCE PAGE 34...
Страница 44: ...DISMANTLING AND REASSEMBLY OF VALVES PAGE 42...
Страница 50: ...FAULT GUIDE PAGE 48...
Страница 68: ...PARTS LIST PAGE 66 80 89 EXTERNAL COMPONENTS 83 4 84 1 83 5 83 6 83 3 83 2 83 1 4 2 81 1 3 4 82 4 2 1 3 4...
Страница 72: ...PARTS LIST PAGE 70 93 95 1ST STAGE CONCENTRIC VALVE 9 8 6 5 4 2 1 3...
Страница 74: ...PARTS LIST PAGE 72 96 97 2ND STAGE CONCENTRIC VALVE 2 1 3 4 5 6 5...
Страница 80: ...PARTS LIST PAGE 78...
Страница 92: ...ANCILLARY PARTS PAGE 90...
Страница 94: ...STANDARD WIRING TERMINAL NUMBERS PAGE 92...
Страница 95: ......