13-11-607 Page 50
SECTION 9
MAINTENANCE SCHEDULE
SERVICE CHECK LIST
Air Filter
- Operating conditions determine frequency of service. When the air pressure differential
across the filter reaches 25” H
2
O, the “CHANGE AIR FILTER” message appears on the display
accompanied by a yellow indicator in the status area of the keypad signaling that the air filter requires
servicing or changing. See “Air Filter,” Section 6, page 39.
Water Filter
- Operating conditions and water quality determine the frequency of service. When the
water pressure differential across the filter reaches 30 psi, the “CHANGE H
2
O FILTER” message appears
on the display accompanied by a yellow indicator in the status area of the keypad, signaling that the water
filter requires changing.
To change the filter:
1. Be sure the unit is completely off and that no air pressure is in the system.
2. Disconnect, tag and lockout the power supply to the starter.
3. Drain the water from the filter housing by either turning the petcock or removing the plug on the
bottom of the filter assembly.
4. Remove the nut at the top of the filter assembly, while holding the filter housing to keep it from
dropping. When the nut is removed, change the filter and reassemble.
5. Repeat Steps 3 and 4 on the makeup water filter.
6. Reconnect the power supply to the starter, start the machine and check for leaks.
RO Water Filtration System
- Operating conditions and water quality determine the frequency of
service. Refer to Section 8 for detailed maintenance instructions.
Motor Lubrication
- Refer to Section 2, page 11.
Every 8 Hours Operation
1.
Observe if the unit loads and unloads properly.
2.
Check discharge pressure and temperature.
3.
Check Panel Status indicators and message line for advisories.
4.
Check that there is condensate flow in the plastic connected between the aftercooler liquids
separator drain and the inlet valve.
5.
Check that there is no accumulation of condensate in the bowl of the control air filter.
6.
Check setting of buffer air pressure regulator – normal pressure is 5 psig to 7 psig.
7.
Check setting of buffer water pressure regulator – normal pressure is 2 psig to 3 psig.
Содержание PUREAIR EWC99C
Страница 7: ...13 11 607 Page 2 Figure 1 2 PACKAGE ILLUSTRATION 307EWC797 B Ref Drawing...
Страница 8: ...13 11 607 Page 3 Figure 1 3 AIR WATER SCHEMATIC 308EWC797 F Ref Drawing...
Страница 25: ...13 11 607 Page 20 Figure 4 2 FLOW CHART FOR SETUP PROGRAMMING 300EWC1255 Ref Drawing...
Страница 38: ...13 11 607 Page 33 Figure 4 4 WIRING DIAGRAM FULL VOLTAGE 305EWC546 B Ref Drawing Page 1 of 2...
Страница 39: ...13 11 607 Page 34 305EWC546 B Ref Drawing Page 2 of 2...
Страница 40: ...13 11 607 Page 35 Figure 4 5 WIRING DIAGRAM FULL VOLTAGE LESS STARTER 306EWC546 B Ref Drawing Page 1 of 2...
Страница 41: ...13 11 607 Page 36 306EWC546 B Ref Drawing Page 2 of 2...