SECTION 1 
DANGER NOTICES 

 

   

DANGER 

Read and understand the following DANGER 

 

NOTICES before moving or operating the pump or 
any pump package unit equipment. 

 
Reciprocating pumps are machines capable of 
producing high fluid pressures and flow rates and 
are designed to be used with proper care and 
caution by trained, experienced operators.  

TO 

AVOID PERSONAL INJURY, DEATH AND/OR 
EQUIPMENT DAMAGE, READ AND 
THOROUGHLY UNDERSTAND THE 
FOLLOWING DANGER NOTICES PLUS THE 
ENTIRE OPERATING AND SERVICE MANUAL 
BEFORE ATTEMPTING TO MOVE OR OPERATE 
THE PUMP

.  Contact a Gardner Denver  service 

representative if you are unable to comply with any 
of the danger notices or procedures described in 
these documents. 

 
Closely examine the data plate upon pump delivery 
to become thoroughly familiar with the operating 
limits for this pump model.  

The pump must never 

be operated at speeds, pressures or 
horsepower exceeding the maximum values 
shown on the data plate or at speeds below the 
minimum shown.  Failure to observe the 
operating limits shown on the data plate could 
result in personal injury, death, and/or 
equipment damage and will void the warranty

.  

Alterations to the pump, or application of the pump 
outside the data plate limits, must not be made 
without Gardner Denver written approval together 
with a new data plate, as dangerous operating 
conditions could result. 
 
THE DANGER NOTICE AND DATA PLATES 
PROVIDED ON THE EQUIPMENT MUST NOT BE 
REMOVED, PAINTED OVER, HIDDEN OR 
DEFACED.  They must be replaced if they become 
damaged or unreadable.  Provisions should be 
made to have the following written danger notices 
plus the pump operating and service manual readily 
available to operators and maintenance personnel.  
In addition, copies of all pump system accessory 
component (e.g. pressure relief valve, pulsation 
dampener, suction stabilizer, engine, electric motor, 
etc.) operating and service manuals should be 
readily available for operator and maintenance 
personnel use.  Read and follow all the precautions 
and instructions contained in these manuals.  If any 
of these documents are lost or become illegible 
they must be replaced immediately.  The danger 

notices plus the operating and service manuals 
should be reread periodically by both operators and 
maintenance personnel to refresh their memories in 
safe procedures and practices. 

 

Keep in mind that full operator attention and 
alertness are required when operating high 
pressure pumping equipment.  Operators 
should not begin or continue operations when 
tired, distracted or under the influence of 
alcohol or any type of prescription or 
nonprescription drugs. 

 
The timely replacement of expendable parts and 
any other worn or damaged parts can prevent 
equipment damage and possible injury.  The 
original parts used in Gardner Denver pumps are 
designed and tested to exacting standards to 
provide high quality performance and durability.  
Your best insurance in maintaining these 
characteristics is to use genuine Gardner Denver 
replacement parts. 

 
A broad range of danger notices are covered on 
these pages, however, they cannot substitute for 
training, experience and common sense in the safe 
operation of high pressure pumping equipment. 

 

 

HAMMER LUG FASTENERS 

   

DANGER 

On pumps or pump package units equipped with 
hammer lug connectors and/or hammer lug valve 
covers the following precautions must be observed 
to avoid personal injury, death and/or equipment 
damage due to contact with the hammer, hammer 
bar, broken parts from the hammer, hammer bar or 
lugs or other objects propelled by hammer blows.  
When tightening or loosening hammer lug 
connectors and valve covers, operators or 
maintenance personnel should: 

 

•  Inspect the hammer, hammer lugs and 

hammer bar, if one is used, to insure they 
are all in good condition.  Replace any of 
these parts which are cracked, damaged or 
badly worn. 

 

• 

Wear safety shoes and goggles. 

 

• 

Alert other personnel to move away from the 
area. 

 

• 

Check to insure they have safe footing. 

Содержание GD-250

Страница 1: ...GARDNER DENVER 3 1 618 Version 1 January 2011 TRIPLEX PISTON PUMP 5 STROKE MODEL GD 250 WELL SERVICE OPERATING AND SERVICE MANUAL Rental Pump Supplied By...

Страница 2: ...ed distributor service technicians are factory trained and skilled in pump maintenance and repair They are ready to respond and assist you by providing fast expert maintenance and repair services For...

Страница 3: ...operation and minimum downtime DANGER Danger is used to indicate the presence of a hazard which will cause severe personal injury death or substantial property damage if the warning is ignored WARNIN...

Страница 4: ...tions 7 Crankcase Oil Requirements 16 Gardner Denver Horizontal Pump Recommended System Layout for Proper Performance 16 Net Positive Suction Head Required NPSHR at Fluid Cylinder Suction Connection w...

Страница 5: ...ting and Cleaning Danger Notice 5 6 Hydraulic Puller Danger Notice 2 INSTALLATION AND OPERATING INSTRUCTIONS SECTION 2 7 Lifting and Moving Equipment Danger Notice 2 Location 7 Lubrication Packing 12...

Страница 6: ...or Temperature Correction Char 21 Wedge Puller Danger Notice 2 LIST OF ILLUSTRATIONS Figure Description Page Figure 1 View of the Eccentric thru the Hood Opening Step 1 18 Figure 2 View of the Eccent...

Страница 7: ...g and service manuals should be readily available for operator and maintenance personnel use Read and follow all the precautions and instructions contained in these manuals If any of these documents a...

Страница 8: ...e handle to avoid losing control of the hammer while swinging and striking Carefully swing the hammer to avoid striking themselves another person and objects other than the targeted wedge Avoid swingi...

Страница 9: ...o lift a pump package unit subassemblies or individual components and you observe the equipment is tilting or appears unbalanced lower the equipment and adjust the lifting device to eliminate these im...

Страница 10: ...han every six months if pressures above 2 500 PSI are used in the discharge system or if corrosive flammable or hot over 110 F fluids are being pumped Before starting the pump the first time and perio...

Страница 11: ...s must be taken to avoid possible personal injury death and or equipment damage from explosion fire or burns HIGH PRESSURE LIQUID JETTING BLASTING AND CLEANING Pressure or flow directing devices often...

Страница 12: ...tion These components should all be tagged with their tested pressure capabilities together with the date testing was performed Always be aware of the pressure level in the system and never connect an...

Страница 13: ...supported independently of the pump to insure that no strain is imposed in the pump by misalignment or improperly fitted pipe PRESSURE RELIEF VALVE The pump must be protected from excessive discharge...

Страница 14: ...f care is taken to stay within the listed temperature ranges Straight weight oils are also ideal in pumps used indoors when ambient temperatures are controlled The oil level in the pump should be chec...

Страница 15: ...the crankcase Drain all water accumulation from the bottom of crankcase Check all nuts and screws and tighten if necessary Fill crankcase with oil of proper grade to proper level Quantity on the data...

Страница 16: ...th a valve seat puller Wipe the tapered surface of the valve seat and pump valve deck in the fluid cylinder with a clean cloth Lower the seat into the port taper and then lift slightly and drop If the...

Страница 17: ...nd rust in the stuffing box pilot bores in the frame Install the packing in the box Place a new gasket in the stuffing box groove The gasket chamfered edge must face out to prevent gasket pinching whe...

Страница 18: ...e placed over a lock pin which has been inserted in a lock pin hole in the gland When using self adjusting packing tighten the gland nut firmly after assembling it metal to metal with the stuffing box...

Страница 19: ...ot contaminate the crankcase oil CROSSHEAD AND PINS Crossheads can be removed through the oil stop head openings Crossheads are equipped with straight pins secured on each end by setscrews and locknut...

Страница 20: ...re Tighten oil stop head gland to prevent seal movement while pump is in operation These oil stop head seals are nonadjustable When crankcase oil leakage occurs past seals the seals should be replaced...

Страница 21: ...the crankcase the oil and filter should be changed Drain and clean out the crankcase before putting in new oil Replace the oil stop head seals before running the pump We recommend oil stop head seals...

Страница 22: ...e or grade used A crankcase heater and or an oil heat exchanger may be needed to meet these requirements Crankcase capacity is 12 gallons 45 4 liters WARNING Failure to follow these lubrication requir...

Страница 23: ...y into tank outlet 4 A short straight suction line is preferred from the tank to the pump If this is not possible use as few bends as possible and use long radius elbows The smallest portion of the li...

Страница 24: ...3 1 618 Page 18 FIGURE 1 STEP 1 FIGURE 2 STEP 2...

Страница 25: ...3 1 618 Page 19 FIGURE 3 STEP 3 FIGURE 4 STEP 4...

Страница 26: ...d minimum plunger sizes Interpolate between NPSH curves for each plunger size NPSHR is defined at a 3 flow drop below maximum capacity Added suction head above that shown by the curves must be provide...

Страница 27: ...3 1 618 Page 21 CORRECTION CHART FOR TEMPERATURE OR VISCOSITY...

Страница 28: ...0 592 64 60 20 45 40 3 106 0 35 9 0 3 9 67 45 800 176 81 00 677 73 80 23 35 35 2 120 0 39 9 8 4 1 74 50 900 198 91 00 762 83 00 26 30 31 3 135 0 41 10 7 4 3 82 58 1000 220 100 7 896 92 10 29 20 28 2 1...

Страница 29: ...mbly 2 Valve propped open 2 Remove prop 3 Pump cavitating 3 See Cavitation Fluid Knock or Hammer problem 4 Fluid leakage 4 Replace fluid end seals 5 Erroneous gauge reading 5 Recalibrate or replace ga...

Страница 30: ...13 Multiple pumps operating in 13 Use a suction stabilizer phase on each pump Separate lines may also be needed Suction or Discharge Line Vibration 1 Line s not supported 1 Install supports or hangers...

Страница 31: ...il stop head packing 2 Replace packing 3 Oil level too high in 3 Reduce oil level crankcase 4 Excessive crosshead wear 4 Replace crosshead 5 Pressure in crankcase 5 Clean or replace air breather Oil S...

Страница 32: ...temperature 5 Lube oil pump failure 5 Replace oil pump 6 Low oil level in sump 6 Check oil level frequently and add oil as required 7 Contaminated oil in sump 7 Check oil condition frequently 8 Cavita...

Страница 33: ...ad Pin 2 0015 2 0020 50 838 50 851 Bore in Connecting Rod Bushing for Eccentric 10 499 10 505 266 675 266 827 Crosshead Pin Diameter 2 0005 2 0000 50 8127 50 8000 Bore in Crosshead for Pin 2 0010 2 00...

Страница 34: ...Service Department Telephone 800 682 9868 FAX 217 223 1581 For Domestic parts information Contact Gardner Denver Fluid Transfer Division 2200 South Prospect Oklahoma City OK 73129 Telephone 405 677 57...

Отзывы: