13–8–610 Page 29
2.
Fill the system with a 50 percent charge of the new
lubricant:
–
Start the machine and stay there to observe.
–
Allow the machine to run about five minutes
at temperature, or until temperature stabi-
lizes, then shut down.
3.
Thoroughly drain the machine.
4.
Change to a new filter and separator.
5.
Fill the system with a full charge of the new lubri-
cant.
6.
Machine should then be run normally, however,
total run time after the initial changeout should be
50 percent of normal anticipated service life of the
new lubricant.
–
Drain all lubricant from the system, change
the filter and separator, and replace with a full
charge of the new lubricant.
7.
Subsequent lubricant changeouts should be at
normal intervals. (See “Oil Change Interval” and
chart, FIGURE 5–3.)
Improper equipment maintenance
with use of synthetic lubricants will
damage equipment. Oil filter and oil
separator change intervals remain
the same as for AEON
t
4000 –– See
Maintenance Schedule, page 38.
Air/oil under pressure will cause
severe personal injury or death. Shut
down compressor, relieve system of
all pressure, disconnect, tag and
lockout power supply to the starter
before removing valves, caps, plugs,
fittings, bolts, and filters.
High temperature operation can
cause damage to equipment or per-
sonal injury. Do not repeatedly restart
the unit after high temperature stops
operation. Find and correct the mal-
function before resuming operation.
All materials used in Gardner Denver
R
compressor units are compatible with
AEON
t
9000 SP Lubricating Coolant.
Use caution when selecting down-
stream components such as air line
lubricating bowls, gaskets and valve
trim.
AEON
t
9000 SP Synthetic Lubricant
is not compatible with low nitrile Buna
N or acrylic paints. AEON
t
9000 SP is
compatible with most air system
downstream components.
FIGURE 5–3 – OIL CHANGE INTERVAL
Discharge
AEON 4000
AEON 9000 SP
Temperature
Change Interval
Change Interval
Up to 180
_
F (82
_
C)
4000 hrs.
8000 hrs.
180
_
to 190
_
F (82
_
to 88
_
C)
3000 hrs.
6000 hrs.
190
_
to 200
_
F (88
_
to 93
_
C)
2000 hrs.
4000 hrs.
200
_
F+ (93
_
C)
1000 hrs.
2000 hrs.
Содержание ELECTRA-SCREW EDEQHH
Страница 10: ...13 8 610 Page 2 200EDE797 Ref Drawing FIGURE 1 2 PACKAGE MINIMUM PRESSURE CHECK VALVE MIXING VALVE OIL FILTER...
Страница 11: ...13 8 610 Page 3 200EDE797 Ref Drawing FIGURE 1 3 PACKAGE OIL LEVEL GAUGE SEPARATOR AIR FILTER...
Страница 12: ...13 8 610 Page 4 202EDE797 Ref Drawing FIGURE 1 4 PACKAGE CONTROLLER STARTER BOX...
Страница 15: ...13 8 610 Page 7 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 16: ...13 8 610 Page 8 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 33: ...13 8 610 Page 25 FIGURE 4 10 WIRING DIAGRAM FULL VOLTAGE DUAL CONTROL 204EDE546 Ref Drawing...
Страница 34: ...13 8 610 Page 26 FIGURE 4 11 WIRING DIAGRAM WYE DELTA 205EDE546 Ref Drawing...
Страница 53: ......