13-21-616 v00 Page 17
DISCHARGE SERVICE LINE
- The discharge service line connection on both water-cooled and air-cooled
units is made at the right hand corner of the unit, viewed from the opposite end from control panel side.
When manifolding two or more rotary screw units on the same line, each unit is isolated by the check valve
in the unit discharge line. If a rotary screw unit is manifolded to another compressor, be sure the other
compressor has a check valve in the line between the machine and the manifold. The check valve function
built into the minimum pressure valve is adequate for this service on your unit. When manifolding multiple
units or even in a singular unit installation, it is highly recommended a full port isolation valve be added into
the discharge service line to allow the unit to be safely isolated during service. If a rotary screw and a
reciprocating compressor are manifolded together, an air receiver must be located between the two units.
BLOWDOWN VALVE PIPING
- The blowdown valve is piped back into the airend between the inlet valve
and air filter.
HEAT EXCHANGER
Water Temperature to
Heat Exchanger
Gallons/minute (Minimum)
Maximum Water
Flow
Gallons/minute *
Approximate Water
Pressure Drop @ 90
F
Water Temperature PSI
HP
Model
60
F
70
F
80
F
90
F
125
SAV125-150G2A
ST125-200G2A
23.7
29.6
39.4
59.1
110
2
150
27.7
34.6
46.1
69.1
110
3
200
38.2
47.8
63.5
95.3
110
4
* Flows exceeding "Maximum Water Flow" will cause severe erosion and will void unit warranty.
Figure 2-5
– HEAT EXCHANGER (OIL COOLER) APPROXIMATE WATER FLOW
Discharge air used for breathing will cause severe injury or death.
Consult filtration specialists for additional filtration and treatment equipment to
meet health and safety standards.