13-21-616 v00 Page 41
FIGURE 4-7 COMPRESSOR PACKAGE CONTROL COMPONENT STATES
Package Control Component States
Action
IVO
Solenoid
IVC
Solenoid
TVO
Solenoid
TVC
Solenoid
BDV
Solenoid
Main
Motor
State
Reservoir
Pressure
(PSIG)
P1
Blowdown
(BD) Test
Port
P2
Inlet
Valve
(IC) Test
Port
MPV
State
Compressor
Flow State
Start Up
Closed
Off
Closed
On
Closed
Off
Open
On
Closed
On
On
D
D
D
Closed
Increasing
Close, TV
Modulate
Closed
Off
Closed
On
Closed
Off
Open
On
Closed
On
On
A
D
D
Open
Increasing
Open, TV Modulate
Closed
Off
Closed
On
Open
On
Closed
Off
Closed
On
On
A
D
D
Open
Decreasing
Open, IV Modulate
Open
On
Closed
On
Closed
Off
Closed
Off
Closed
On
On
A
D
D
Open
Increasing
Close, IV Modulate
Closed
Off
Open
Off
Closed
Off
Closed
Off
Closed
On
On
A
D
B
Open
Decreasing
Blowndown
Closed
Off
Open
Off
Closed
Off
Closed
Off
Open
Off
On
C
C
B
Closed
0
Stopped
Closed
Off
Open
Off
Closed
Off
Closed
Off
Open
Off
Off
D
D
D
Closed
0
A = Full System Pressure B = 60 psig, Control Pressure C = 30-40 psig D = 0 psig, Atmospheric
Closed = No Flow Through Valve Open = Flow through Valve Off = Not Electrically Energized On = Electrically Energized
Содержание ELECTRA-SAVER
Страница 41: ...13 21 616 v00 Page 40 FIGURE 4 6 COMPRESSOR PACKAGE P ID 300EBF797 EB Ref Drawing...
Страница 55: ...13 21 616 v00 Page 54 300EBF797 EB Ref Drawing Figure 5 3 FLOW DIAGRAM AIR OIL SYSTEM...
Страница 56: ...13 21 616 v00 Page 55 301EBG797 00 Ref Drawing Figure 5 4 OIL FLOW DIAGRAM REMOTE MOUNTED COOLER...