37-1-615 Page 21
EMERGENCIES
– In event of system failures, shutdown the blower immediately. Inspect the blower for
foreign material backflow. If materials are found inside the blower housing, a thorough cleaning is
necessary before restarting.
Do not operate a blower which is noisy, vibrating, or heating excessively.
Models
Minimum Speed (RPM) – Dry Pressure
Up to
15 PSIG
18 PSIG
20 PSIG
9CDL13
1050
1280
1540
9CDL18
1050
1050
1230
9CDL23
1050
1050
1300
Models
Minimum Speed (RPM)
Dry Vacuum
Wet Vacuum
Up to
17” Hg.
Up to
22” Hg.
24” Hg.
9CDL13
1185
1050
1050
9CDL18
1055
1050
1050
9CDL23
1050
1050
1050
FIGURE 3-6 – MINIMUM SPEED, MAXIMUM PRESSURE OR VACUUM