8
7
2
6
0
9
Attaching the collection bag:
NOTE: A safety switch will prevent the unit from starting if the
elbow tube
7
is not installed correctly.
1. Align the grooves on the elbow tube
7
with the grooves on the
blower outlet
2
.
2. Press the elbow tube
7
onto the blower outlet
2
until it snaps
into place.
The collection bag is secured to the blower outlet with the tube
release button
8
.
3. Clip the collection bag
9
into both loops
0
on the vacuum
tube
6
.
To remove the collection bag
9
, press the tube release button
8
and pull out the elbow tube
7
at the same time.
Attaching the shoulder strap:
q
For extra support when using your unit as a vacuum, a shoulder
strap is included with your unit. Attach the strap to the unit before
operation. Snap the hook onto the retainer
q
.
3. Operation
WARNING:
Do not use the unit without the tubes or collection bag properly
attached to avoid flying debris and/or impeller contact which can cause serious
injury. Always wear gloves and use eye protection to prevent rocks or debris from
being blown or ricocheting into the eyes and face which can result in blindness or
serious injury.
Cables:
Use only 1.00mm
2
size cable up to 40 metres length maximum.
Maximum rating:
1.00mm
2
size cable
ErgoJet 3000 (EJ3000): 3000 W
ErgoJet 2500 (EJ2500): 2500 W
Mains cables and extensions are available from your local
approved service centre. Only use extension cables specifically
designed for outdoor use.
21
GB