GAT Access 6100 Terminal Series
Commissioning & Configuration
58
HB_GAT-ACCESS6100--EN_14
www.gantner.com
Second Ident screen
Duration in milliseconds for the second identification
process.
Integer
3000
Reader
LEGIC
Options for reading of LEGIC data carriers.
Site key
Site key of the device. All data carriers must have the
same site key to be used at the device.
Hex
9999
Subsite
Additional key for division of site keys.
Hex
00
Subsite enabled
If enabled the subsite keys of data carriers will be checked.
Boolean
false
Same segments structure
Set this to true, if all data carriers use the same segment
structure. Enables faster reading of data carriers.
Boolean
true
MIFARE
Options for reading of MIFARE data carriers.
Site key
Site key of the device. All data carriers must have the
same site key to be used at the device.
Hex
73E0818B…
Subsite
Additional key for division of site keys.
Hex
00
Enable subsite
If enabled the subsite keys of data carriers are checked.
Boolean
false
Third party site key
Site key to be used for the third party segment.
Hex
22E0818B…
Third party read key
Read key to be used for reading the third party data.
Selection
Key A / Key B
Third party write key
Write key to be used for writing the third party data.
Selection
Key A / Key B
DESFire
Options for reading of MIFARE DESFire D
Key Set
Key Set containing Keys for DESFire Read/Write, if
invalid DESFire easy is used
Hex
Application ID
DESFire application ID number
Hex
012ABC
Read Key Number
Number of the read key
Integer
1
Write Key Number
Number of the write key
Integer
2
ISO
Options for reading of ISO 15693 data carriers.
Site key
Site key of the device. All data carriers must have the
same site key to be used at the device.
Hex
73E0818B…
Subsite
Additional key for division of site keys.
Hex
00
Subsite enabled
If enabled the subsite keys of data carriers are checked.
Boolean
false
Read only parameter
Production
Production Data
Production data of the device (set at manufacturer)
Hex
Hardware Version
Hardware version of the device hardware
Integers
2.2.0
Serial Number
Serial number of the device
Integer
Software Version
Software version of the application
Integers
5.3.0
Table 5.20 - Configuration options for GAT Access 6100
Note for online mode:
If the host computer only requires the unique number of a data carrier, deleting all reading
options makes the process faster as the data carrier does not need to be read.
Содержание GAT ACCESS 6100
Страница 10: ...GAT Access 6100 Terminal Series Table of Contents 10 HB_GAT ACCESS6100 EN_14 www gantner com ...
Страница 18: ...GAT Access 6100 Terminal Series General Information 18 HB_GAT ACCESS6100 EN_14 www gantner com ...
Страница 34: ...GAT Access 6100 Terminal Series Installation 34 HB_GAT ACCESS6100 EN_14 www gantner com ...
Страница 42: ...GAT Access 6100 Terminal Series Electrical Connections 42 HB_GAT ACCESS6100 EN_14 www gantner com ...
Страница 80: ...GAT Access 6100 Terminal Series Operation 80 HB_GAT ACCESS6100 EN_14 www gantner com ...
Страница 84: ...GAT Access 6100 Terminal Series Updating the GAT Access 6100 84 HB_GAT ACCESS6100 EN_14 www gantner com ...
Страница 92: ...GAT Access 6100 Terminal Series Troubleshooting FAQ 92 HB_GAT ACCESS6100 EN_14 www gantner com ...