GAT Access 6100 Terminal Series
Operation
www.gantner.com
HB_GAT-ACCESS6100--EN_14
77
When in pause mode it is possible to stop/cancel the countdown process before the configured runtime has ended.
For this functionality, the correct timeout and action must be set in the configuration settings (see chapter "5.4.3 List
of Configuration Settings") via the "Remaining period mode" setting in the "Application -> General" section and the
"Remaining period break" settings in the "Application -> Timeouts" section).
If, during a pause, the equipment is not resumed during the defined "Remaining period break" the set "Remaining
period mode" will determine:
-
If the countdown process is cancelled immediately
-
If the countdown process is resumed and the terminal relay is switched on (= equipment on)
-
If the countdown process is resumed and the terminal relay is switched off (= equipment off)
6.8
Online Mode and Emergency Mode
Online mode is the regular mode for operation. The GAT Access 6100 must communicate with a server/host that
decides if the data carrier is valid and if the controlled door or turnstile may be unlocked.
If the server/host is not available or is not responding to the requests of the GAT Access 6100 the terminal will switch
into the Emergency mode (if configured). In this mode, the access terminal only reads the site key of the data carrier
and grants access if this is valid (i.e., the same as the site key in the GAT Access 6100).
For the GAT Access 6100 F Enrollment Station, the configuration settings determine if the device displays the icons
that allow users to enroll and check fingerprints, or if these icons are not displayed.
Emergency mode is not indicated via the display or the status LEDs.
6.9
Out of Order Screen
When communication of the GAT Access 6100 is interrupted and the GAT Access 6100 is not configured for
Emergency mode, the terminal switches into Out of Order mode. The following message is displayed on the LC
display.
Figure 6.11 - Out of order screen of GAT Access 6100
The GAT Access 6100 will listen on the configured TCP/IP port (default 8000).
Содержание GAT ACCESS 6100
Страница 10: ...GAT Access 6100 Terminal Series Table of Contents 10 HB_GAT ACCESS6100 EN_14 www gantner com ...
Страница 18: ...GAT Access 6100 Terminal Series General Information 18 HB_GAT ACCESS6100 EN_14 www gantner com ...
Страница 34: ...GAT Access 6100 Terminal Series Installation 34 HB_GAT ACCESS6100 EN_14 www gantner com ...
Страница 42: ...GAT Access 6100 Terminal Series Electrical Connections 42 HB_GAT ACCESS6100 EN_14 www gantner com ...
Страница 80: ...GAT Access 6100 Terminal Series Operation 80 HB_GAT ACCESS6100 EN_14 www gantner com ...
Страница 84: ...GAT Access 6100 Terminal Series Updating the GAT Access 6100 84 HB_GAT ACCESS6100 EN_14 www gantner com ...
Страница 92: ...GAT Access 6100 Terminal Series Troubleshooting FAQ 92 HB_GAT ACCESS6100 EN_14 www gantner com ...