![Galil Motion Control DMC-1600 Series Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/galil-motion-control/dmc-1600-series/dmc-1600-series_user-manual_3256992043.webp)
The optoisolated inputs are connected in the following groups
Group (Controllers with 1- 4 Axes)
Group (Controllers with 5 - 9 Axes)
Common
Signal
IN1-IN8, ABORT
IN1-IN16, ABORT
INCOM
FLX,RLX,HOMEX
FLY,RLY,HOMEY
FLZ,RLZ,HOMEZ
FLW,RLW,HOMEW
FLX,RLX,HOMEX,FLY,RLY,HOMEY
FLZ,RLZ,HOMEZ,FLW,RLW,HOMEW
FLE,RLE,HOMEE,FLF,RLF,HOMEF
FLG,RLG,HOMEG,FLH,RLH,HOMEH
LSCOM
LSCOM
FLSX
RLSX
HOMEX
FLSY
RLSY
HOMEY
INCOM
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8 ABORT
Figure 3-1. The Optoisolated Inputs
Using an Isolated Power Supply
To take full advantage of opto-isolation, an isolated power supply should be used to provide the
voltage at the input common connection. When using an isolated power supply, do not connect
the ground of the isolated power to the ground of the controller. A power supply in the voltage
range between 5 to 28 Volts may be applied directly (see Figure 3-2). For voltages greater than 28
Volts, a resistor, R, is needed in series with the input such that
1 mA < V supply/(R + 2.2K
Ω
) < 15 mA
DMC-1600
Chapter 3 Connecting Hardware
•
35