Output Isolation
The first four digital outputs on the ICM-3300 are set up as high current isolated outputs and are
configured for High Side (Sourcing) operation. The outputs are capable of sourcing 500 mA per
output. Digital outputs 5-10 and the Amp Enable/Error output are low power opto-outputs. The output
will be at the voltage that is supplied to the OUTSUP pin. Up to 24 VDC may be supplied to
OUTSUP.
The resistor packs RP10, RP11 and RP12 allow for the configuration of the active state of the outputs.
For example when you issue the SB1 command, the polarity of the resistor pack will determine
whether the output is turned on or off.
RP10
RP6
OUTSUP (+5 to +24V)
OUTRET (-)
Load
DO 1-4
Pin1 to GND, SB=+V
Pin 1 to +5V, SB=GND
RP10 can be reversed to
invert output logic
ICM-3300
Machine
RP5
2.2k
GND or +5V
10k
10k
Figure 3: ICM-3300 General-Purpose Opto-Isolation for Outputs 1-4
2.2k
Pin1 to GND, SB=+V
Pin 1 to +5V, SB=GND
RP11 & RP12 can be reversed
to invert output logic:
RP11 = Outputs 5 - 8
RP12 = Outputs 9 -10, Err/AEN
ICM-3300
OUTSUP (+5 to +24V)
GND or +5V
OUTRET (-)
Load
Machine
Digital Outputs 5-10, Error/AEN
10k
RP7
Figure 4: Outputs 5-10 and Error/Amp Enable are low-power opto-outputs with the above circuit
RP11, 12
Содержание CDS-3310
Страница 26: ...18 i Chapter 2 Getting Started CDS 3310 THIS PAGE LEFT PLANK INTENTIONALLY...
Страница 32: ...24 i Chapter 3 Connecting I O CDS 3310 THIS PAGE LEFT PLANK INTENTIONALLY...
Страница 124: ...CDS 3310 Chapter 8 Hardware Software Protection i 63 THIS PAGE LEFT PLANK INTENTIONALLY...
Страница 138: ...CDS 3310 Chapter 10 Theory of Operation i 77 THIS PAGE LEFT BLANK INTENTIONALLY...