CDS-3310
Chapter
10 Theory of Operation
i
73
Digital Filter
KP = 12.5, KD = 245, T = 0.001
Therefore,
D(z) = 1030 (z-0.95)/Z
Accordingly, the coefficients of the continuous filter are:
P
=
50
D
=
0.98
The filter equation may be written in the continuous equivalent form:
G(s) = 50 + 0.98s = .098 (s+51)
The system elements are shown in Fig. 10.7.
Σ
50+0.980s
318
V
ENCODER
500
S
2
FILTER
2000
S+2000
0.0003
4
ZOH
DAC
AMP
MOTOR
Figure 10.7 - Mathematical model of the control system
The open loop transfer function, A(s), is the product of all the elements in the loop.
A = 390,000 (s+51)/[s2(s+2000)]
To analyze the system stability, determine the crossover frequency,
ω
c at which A(j
ω
c) equals one.
This can be done by the Bode plot of A(j
ω
c), as shown in Fig. 10.8.
1
4
0.1
50
200
2000
W (rad/s)
Magnitude
Figure 10.8 - Bode plot of the open loop transfer function