OPERATION
DETAILED CONTROLS AND GAUGES
Emergency Pump Drive Switch
NOTICE
This switch is installed to make it possible to carry out operation temporarily if any abnormality should occur in the pump
control system. It is not intended for permanent use. Repair the cause of the abnormality immediately.
If this switch is depressed and moved to the EMERGENCY position by mistake, thereby engaging the machine in the work,
while the machine is in normal condition, an "E02" mark is shown in the display.
If "E02" is displayed during the work, check that the switch is in the NORMAL position.
This switch (7) is used to make it possible to carry out operations
temporarily if any problem should occur in the pump control system
(when the display shows "E02").
(a) EMERGENCY: When abnormal (move switch up)
(b) NORMAL: When normal (move switch down)
If the display shows "E02", move the switch up to make it possible
to carry out work.
Emergency Boom Swing Operation/Brake Cancel Switch
NOTICE
This switch is installed to make it possible to carry out swing operations temporarily if any abnormality should occur in the
swing brake system, and to make it possible to carry out boom swing operations if any abnormality should occur in the boom
swing system. It is not intended for permanent use. Repair the cause of the abnormality immediately.
If this switch is moved to the EMERGENCY position by mistake and operations are carried out when the machine is normal,
"E03" or "E41" appears on the display.
If "E03" or "E41" is displayed during operations, check that the switch is at the NORMAL position.
This switch (8) is used to make it possible to carry out swing
operations temporarily if any abnormality should occur in the swing
brake system (when the display shows "E03"), and to make it
possible to carry out boom swing operations temporarily if any
abnormality should occur in the boom swing system (when the
display shows "E41").
(a) EMERGENCY: When there is an abnormality (switch at top), it
is possible to carry out boom swing operations
and swing operations for the upper structure.
(b) NORMAL: When condition is normal (switch at bottom), set to
this position.
If the display shows "E03" or "E41", move the switch up to make it
possible to carry out work.
3 - 17
Содержание PC78MR-6
Страница 2: ... 1 1 ...
Страница 4: ... FOREWORD FOREWORD 1 3 ...
Страница 5: ... FOREWORD FOREWORD 1 4 ...
Страница 15: ... ...
Страница 16: ... 2 1 ...
Страница 20: ... SAFETY SAFETY LABELS LOCATION OF SAFETY LABELS 2 5 ...
Страница 55: ... ...
Страница 56: ... 3 1 ...
Страница 195: ... ...
Страница 196: ... 4 1 ...
Страница 271: ... ...
Страница 272: ... 5 1 ...
Страница 275: ... ...
Страница 276: ... 6 1 ...
Страница 294: ... ...
Страница 295: ... PC78MR 6 GALEO HYDRAULIC EXCAVATOR Form No TEN00074 00 2005 KOMATSU All Right Reserved Printed in Japan 04 05 ...