OPERATION
TROUBLES AND ACTIONS
Problem
Main causes
Remedy
Abnormal noise generated
(combustion or mechanical)
Low grade fuel being used
Overheating
Damage inside muffler
Excessive valve clearance
Change to specified fuel
See "Red range of engine
coolant temperature gauge lights
up"
Replace muffler
(
Adjust valve clearance)
Engine stops while in work
Clogging feed pump pre-filter
Defective engine and fuel line
Replace filter cartridge
(
Check, repair)