1
Gal Pro
Instruction 1.0
Sequence Status
This menu shows the current status of the sequences.
Subject
Example
Explanation
Sequence
Number
1
The sequence to which the parameters are related. Change the
sequence number by the Next and Prev keys.
Irrigat
The current sequence status. The options are: "N.Activ", "Def
Err", "Timing", "By Cond", "Active", "Alarm", "Pause", "Fault",
"Waiting", "FltWait", "Irrigat", "Fertig.", "FltIrig", "FltFert"
Pause Seq.-Min. 0
Enables pausing the sequence for a predefined time in minutes.
Next Irr.Time
14:30
The next irrigation start time in the sequence. Editable.
Days to Next Ir.
1
0=today, 1=tomorrow and so on. Editable.
Irr.Cycles Left
1
Editable.
Time left Min.
45
Time remaining to the end of the sequence.
Manual Oper.
Automat
Use the "+" and "-" keys to manually alter the sequence status:
Automat - the normal state.
Start - Start the sequence again.
Stop - Stops the current cycle.
Pause - Permanently pauses the current cycle.
CnclTdy - The sequence will not irrigate today.
Valve 1. Finish
Start
Enables manual control for each valve in the sequence. The
following options are available:
Automat
Start
Stop
Pause
CnclTdy
As noted Gal Pro AC can open about 4 valves simultaneously.
Valve 0. None
Automat
Valve 0. None
Stop
Valve 0. None
Pause
Valve 0. None
CnclTdy
Valve 0. None
Automat
Valve 0. None
Automat
Valve 0. None
Automat
Today Wtr.Mul.
0%
Enables changing the amount of water in all of the valves in the
sequence today.
Cncl.Fert.Today
Yes
Enables canceling fertilization today.
Press + to reset
the sequence
To reset the sequence press "+" and then "enter".
Resets the sequence data to zero.
Setup State
OK
If there are any definition errors they will be displayed here. The
options are:
"N.Activ", "Def. OK", "Vlv.Def", "Tim.Def", "No Time"
7. Information and Programming Menus
Services
System Setup
Sequence Setup
Filter Flush
Fertilization
Sequence Timing
Valve • Water & Fert.
Water
Counter
Diaries
Alarms
Valve Info
Sequence Info
Manual Overriding
Sequence Status
Valve Status
System Status
Содержание Gal Pro DC
Страница 1: ...GalPro AC DC Operating Manual...
Страница 2: ......