1
Gal Pro
Instruction 1.0
e. Output Initialization
The controller performs the initialization process automatically when connected to the power. Usually
there is no need to perform this process unless you want to technically check solenoids due to
replacement. Details about this process are further explained in the "Maintenance" chapter.
f. Irrigation Head Definition
System Setup Menu
Turn the selector to the system setup menu and enter the required
definition according to the following table: (the values shown in the
"Example" column are for illustration purposes only - please enter
(when applicable) your required values)
Subject
Example
Explanation
System
Active
At this stage leave the head Not Active.
Options:
System Not Active - Stops all system activity and erases the
accumulation data. The programming data and constants are
not affected.
System Active - System is active - the normal status.
Fixed System Pause - Stops all system activity.
Fixed Main Open - The system is working automatically
(normally), the main valve is always open. It will only close in
the case of a fault.
Queue Operation
Yes
Yes - Sequences work one at a time (not simultaneously).
No - Sequences work simultaneously under the following
conditions:
a. Irrigation without fertilizers.
b. Fertilization when the units are liter/m3 with the same
amount and without "water before/after".
c. One of the valves is not on the fertilizer route.
Opn.Main Order
Aft.
Aft. - The main valve opens after the irrigation valve.
Sim. - The main valve opens simultaneously with the
irrigation valve.
Bef. - The main valve opens before the irrigation valve.
Open Delay Sec.
10
The time delay between the main and irrigation valve
according to the previous definition.
Cls.Main Order
Bef.
See "Open Main Order".
Close Delay Sec.
20
The time delay between the main and irrigation valve
according to the previous definition.
5. Controller Definition
Services
System Setup
Sequence Setup
Filter Flush
Fertilization
Sequence Timing
Valve • Water & Fert.
Water
Counter
Diaries
Alarms
Valve Info
Sequence Info
Manual Overriding
Sequence Status
Valve Status
System Status