2
Gal Pro
Instruction 1.0
Sequences Setup
In this menu define the constants of the sequence for the first time
before programming the sequence.
Subject
Example
Explanation
Sequence No
1
Change the number of the sequence by the Next and Prev
keys.
Sequence Active
Yes
Select Yes for every active sequence.
Priority
Normal
Via the "+" and "-" keys select one of the options:
Low, Normal, High. The priority of the sequence determines
the order of irrigation in the case of a conflict.
1st Valve Number
1
The first valve that irrigates in the sequence.
2nd Valve Number
2
The second valve that irrigates in the sequence.
3nd Valve Number
8
The third valve that irrigates in the sequence.
4th Valve Number
0
The fourth valve that irrigates in the sequence.
5th Valve Number
0
The fifth valve that irrigates in the sequence.
6thValve Number
0
The sixth valve that irrigates in the sequence.
7th Valve Number
0
The seventh valve that irrigates in the sequence.
8th Valve Number
0
The eighth valve that irrigates in the sequence.
Fix.Wtr Multip
100%
Enables changing all of the water amounts by one
parameter.
Cancel Fertiliz.
No
Enables canceling fertilizing even when the fertilizer is
programmed.
Start Cond.Inp.
0
Enter the condition input number to start irrigation.
Stop Cond.Inp.
1
Enter the condition input number to stop irrigation.
Pause Cond.Inp.
3
Enter the condition input number to pause irrigation.
Oper. Cond.Inp.
2
Enter the condition input number to operate irrigation.
For further information about condition inputs see the "Advanced Setup" (p40).
6. Programming
Services
System Setup
Sequence Setup
Filter Flush
Fertilization
Sequence Timing
Valve • Water & Fert.
Water
Counter
Diaries
Alarms
Valve Info
Sequence Info
Manual Overriding
Sequence Status
Valve Status
System Status
Содержание Gal Pro DC
Страница 1: ...GalPro AC DC Operating Manual...
Страница 2: ......