1
Gal Pro
Instruction 1.0
Subject
Example
Explanation
Overlap Time Sc.
10
The closing valve closes 10 seconds after the next valve in
order to prevent water shock.
Pause-Cond.Input
1
If using "condition input" in order to "pause" the whole
system, enter the number here. See detailed explanation in
"Advanced Operation" (p.40).
Fill-Dly m3
2.0
Amount of water passing through the water meter from the
start of irrigation until activating flow alarms.
Fill Delay Mnt.
5
The time that passes from start of irrigation until activating
flow alarms.
If both fill delays (time and amount) are defined the first to
occur will activate flow alarms.
Flow Dev. Unit
M3/H
The unit for flow control (M3/H or %).
Flow Delay Unit.
M3
The flow delay unit for the definition in "Valve - Water&Fert."
menu.
Fixd.Wtr Mult.
100%
Enables changing the amounts of all the valves at once. 0
- 200 %. When programmed "Water Mult." appears in the
"System Status" menu.
Fixd.Cancl Fert
No
Cancel fertilizing even though there is a fertilizer program.
Cnd.1 OnDly-Sc
10
Delay in seconds to start according to condition input.
Cnd.1 OffDly-S.
10
Delay in seconds to stop according to condition input.
Cnd.2 OnDly-Sc.
10
See Condition 1.
Cnd.2 OffDly-S.
10
See Condition 1.
Cnd.3 OnDly-Sc.
10
See Condition 1.
Cnd.3 OffDly-S.
10
See Condition 1.