Gal Pro
Instruction 1.0
5. Controller Definition
Fertilization Menu
Turn the selector to the "Fertilzation" menu.
The first row shows Pump Status N.Active
Move down until you reach: Fert. Pump Setup
Enter the parameters as follows:
Subject
Example
Explanation
Pump Type
By Pulse
When the system has a fert. counter, define: By Pulse
if not define: Venturi
Puls.Size Mil
100
Only define if the system has a fert. counter.
Pump.Flow L/H
200 L/H
This parameter must be defined when the pump is defined as
Venturi. If it is not defined a
"Fert. Pump Error" message appears.
Pulse Time Sec.
10
This parameter is necessary when operating a Venturi type
fertilizer pump with proportional fertilization.
Continuous
Yes
During proportional fertilization:
Yes - The fertilizer pump fertilizers all of the required amount
between 2 pulses of water continuously.
No - The fertilizer pumps work alternately between the 2
pulses of water according to the previous parameter.
Pipe Delay-Sec.
10
Defines the amount of time before starting the fertilizer pump
in order to stabilize the water pressure.
Water Delay-Puls.
3
The number of water pulses that pass through the water
meter before the fertilizing process starts.
No Pulse Sec.
180
The time out of the fertilizer pulses. If after that time a pulse
is not received the system alarms. This could be due to lack
of water or a faulty fertilizer meter.
Leakage Pulses
10
The maximum number of pulses that the system allows
before issuing an alarm. This parameter helps to prevent
false alarms.
Auto Reset Flts
No
In the case of automatic alarm canceling, whether the
fertilizer pump participates in the alarm canceling. It is
recommended to select No.
Services
System Setup
Sequence Setup
Filter Flush
Fertilization
Sequence Timing
Valve • Water & Fert.
Water Counter
Diaries
Alarms
Valve Info
Sequence Info
Manual Overriding
Sequence Status
Valve Status
System Status
Содержание Gal Pro DC
Страница 1: ...GalPro AC DC Operating Manual...
Страница 2: ......