4. MAINTENANCE OPERATIONS. RECOMMENDATIONS. 

In order for the equipment to have a long life we must 

follow  some  essential  rules  for  maintenance  and  use. 
Abide by these recommendations.

 

CORRECT  MAINTENANCE  OF  THE  EQUIPMENT  WILL 
AVOID A GREAT PERCENTAGE OF FAULTS. 
 

4.1 MACHINE MAINTENANCE. GENERAL 
RECOMMENDATIONS. 

Before  carrying  out  any  operation  on  the  machine  or 

welding  cables,  we  must  place  the  switch  of  the  equip-
ment in "O" position of machine disconnected. 

Specialized personnel must handle the machine to car-

ry out maintenance and repair operations. 

 

 BLOW THE INSIDE OF THE MACHINE WITH 

COMPRESSED AIR FROM TIME TO TIME. 

The accumulation of metal dust on the inside is one of 

the main causes of breakdowns in this type of equipment 
as they are subject to a great amount of pollution. As an 
essential measure, the equipment must be kept separate 
from  the  welding  place,  not  placing  it  a  short  distance 
away.  Keeping  the  machine  clean  and  dry  is  essential. 
The  inside  must  be  blown  as  required.  We  must  avoid 
any anomaly or deterioration due to the accumulation of 
dust.  Blow  the  inside  of  the  equipment  with  clean  dry 
compressed air. As routine to guarantee that the equip-
ment  works  correctly,  check  that  once  the  machine  has 
been  blown  the  electrical  connections  are  still  properly 
tightened.

 

WARNING!:  SEPARATE  THE  MACHINE  SUFFICIENTLY 
FROM THE WORKSTATION.  

 

PREVENT METAL DUST ENTERING THE EQUIPMENT. 

 

 

 LOCATE THE EQUIPMENT IN A PLACE WHERE 

CLEAN AIR IS CONSTANTLY REPLACED. 

 

 

The machine ventilations must be kept free. It must be 

located in a place where clean air is renewed.

 

 THE MACHINE MUST ALWAYS BE OPERATED WITH 

THE HOUSING ON. 

 

DO NOT DISCONNECT THE MACHINE IF IT IS 

HOT. 

 

 

If  you  have  finished  the  work  do  not  disconnect  the 

machine immediately, wait until the inner cooling system 
has totally cooled it. 

 

KEEP THE WELDING ACCESSORIES IN GOOD 

CONDITIONS FOR USE. 

 

 

ONCE THE WELDING OPERATION HAS 

FINISHED AVOID DIRECT CONTACT OF THE 
ELECTRODE-HOLDER CLAMP WITH THE WELDING 
EARTH CLAMP AND THE OTHER PARTS 
CONNECTED TO IT. 

 

 

KEEP THE WELDING GUN IN GOOD 

CONDITIONS FOR USE. 

A damaged or worn gun can cause inefficient weld-

ing. 

 

 

WHEN FINISHING THE WELDING OPERATION 

MAKE SURE THAT THE TORCH CATCH IS UNLOCKED. 
(If mechanical lock guns are used)

 

 

4.2 RECOMMENDATIONS FOR REDUCING 
ELECTROMAGNETIC COMPATIBILITY (CEM) 
PROBLEMS.  

 

The  user  is  responsible  for  the  installation  and  use  of 

the welding material according to the instructions in this 
manual and the following recommendations. 
 

Before installing the welding material, the presence of 

the  following  in  the  surrounding  area  must  be  kept  in 
mind: 
 

 

Wiring  for  power,  control,  signalling,  and  tele-
phones. 

 

Radio and television receivers and transmitters. 

 

Computers and other control equipment. 

 

Critical security equipment. 

 

People with pace makers or hearing aids. 

 

Measurement and calibration equipment. 

 

In  order  to  reduce  EMC  problems,  keep  in  mind  the 

time of day when welding or other activities will be car-
ried  out.  Move  possible  interference  victims  away  from 
the welding installation. 
 

ALWAYS CONNECT THE MACHINE TO POWER 

USING AN EFFICIENT EARTH TAP. 

 

IF PROTECTIVE DEVICES OR SUPPLEMENTARY 

ELECTRICAL SYSTEM FILTERS ARE NEEDED, CONSULT 

OUR TECHNICAL SERVICE. 

 

PERFORM THE MAINTENANCE OPERATIONS 

DESCRIBED IN THIS MANUAL. 

 

USE THE SHORTEST WELDING WIRES POSSIBLE 

AND KEEP THEM PLACED NEXT TO EACH OTHER NEAR 

THE FLOOR. 

 

EQUIPMENT FORESEEN FOR USE IN INDUSTRIAL 

ENVIRONMENT. ELECTROMAGNETIC DIFFICULTIES 

MAY EXIST IN OTHER ENVIRONMENTS CAUSED BY 

CONDUCTED AND RADIATED DISTURBANCES. 

 

 

IF THE WELDING PIECE IS GROUNDED, KEEP IN 

MIND OPERATOR SAFETY AND NATIONAL 
REGULATIONS

.

 

Содержание GPS 3000 C

Страница 1: ...OF SYNERGIC CONTROL Ref 423 85 000 GPS 3000 C 400V 50 60Hz Ref 423 55 000 GPS 3000 C 440V 50 60Hz Ref 423 84 000 GPS 4000 C 400V 50 60Hz Ref 423 54 000 GPS 4000 C 440V 50 60Hz E ESTE EQUIPO DEBE SER U...

Страница 2: ...D 100 250 A 100 270 A 100 Regulaci n de tensi n de soldadura U2min U2max 12 32 V 12 34 V de hilo aplicables mm 0 8 1 2 mm 0 8 1 2 mm Bobinas rollo de hilo 300 mm 15 Kg 300 mm 15 Kg Velocidad hilo m mi...

Страница 3: ...filador de tungstenos 259064 Cable acr lico con pinza 50 mm2 4 mt 500 A 43912063 Cable de masa 50 mm2 4 mt 400 A En GPS 4000 C 43812219 Cable de masa 35 mm2 4 mt 300 A En GPS 3000 C 1704V10 Estufa TRC...

Страница 4: ...e apa rato es la de proteger a las personas de contactos directos o indirectos con partes el ctricas bajo tensi n El interruptor diferencial se selecciona de un calibre superior a ID La conexi n a la...

Страница 5: ...H Manguera de alimentaci n I O I Interruptor general ON OFF M Manetas de regulaci n de presi n de arrastre de hilo K Motor de arrastre N Sistema de cambio de polaridad de Euroconector de conexi n de...

Страница 6: ...dar MODO JOB Selecci n N JOB SETUP CONFIGURACI N Modificaci n variable de ciclo D3 MMA TIG Regulaci n intensidad de soldadura P1 Selecci n PROCESO soldadura P2 PROCESO MIG Selecci n PROGRAMA soldadura...

Страница 7: ...PULSE PULSE MIG MIG SPOT MIG PULSE MIG Bi Pulse MIG SPOT PULSE MMA TIG TIG PULSE Software disponible Incluido Incluido OPCIONAL Ref 42370010 OPCIONAL Ref 42370011 OPCIONAL Ref 42370010 Incluido Inclu...

Страница 8: ...combustion 20 20 msg 1 0 TPR Tiempo pre gas 0 0 3 0 s 0 1 0 3 TPS Tiempo post gas 0 0 5 0 s 0 1 0 4 REF Modo refrigeraci n OFF ON AUT OFF DIM Sistema dimensional mm in mm Restricci n por modo 2T 4T 4...

Страница 9: ...URACI N DE PAR METROS PROCESOS MMA P1 SELECCIONAR PROCESO P1 ENTRAR SETUP E1 SELECCIONAR PAR METRO E2 REGULAR VALOR P1 GUARDAR PAR METROS 2 2 PAR METRO RANGO MEDIDA RESOLUCI N RESET STD CEL HOT Refuer...

Страница 10: ...OFF Restricci n por modo VAL 2T 4T VAL 2T 4T TPR Tiempo pre gas 0 0 5 0 s 0 1 0 3 IS Intensidad inicio 10 100 1 30 UPS Rampa ascenso 0 0 10 0 s 0 1 0 4 IB Intensidad base 10 100 1 50 DCL Intensidad al...

Страница 11: ...mente la m quina espere a que el sistema de refrigera ci n interior la enfr e totalmente MANTENGA EN BUENAS CONDICIONES DE USO LOS ACCESORIOS DE SOLDADURA UNA VEZ FINALIZADA LA OPERACI N DE SOLDEO EVI...

Страница 12: ...teriormente una conexi n floja Revisar conexiones el ctricas de potencia M QUINA CONECTADA Y CON LD1 ILUMINADO AL PULSAR NO REACCIONA Fallo del interruptor de la pistola que no realiza perfectamente e...

Страница 13: ...ocar con la pieza no quede frenado La longitud de hilo al comenzar el proceso de soldadura es muy larga Corrija en el men de configuraci n el valor de la correc ci n de tiempo de burn back TBB Presenc...

Страница 14: ...mismo puede suceder con aquellos materiales que incorporen alg n tipo de tratamiento superficial cincado galvanizado etc Ev tese en todo momento la inhalaci n de los humos desprendidos en el proceso...

Страница 15: ...100 250 A 100 270 A 100 Welding voltage adjustment U2min U2max 12 32 V 12 34 V Applicable wire diameter s mm 0 8 1 2 mm 0 8 1 2 mm Wire reels 300 mm 15 Kg 300 mm 15 Kg Wire speed m min 1 24 m min 1 24...

Страница 16: ...Free Argon 600000 CO2 gas heater 8044166 NT Tungsten electrode sharpener 259064 Acrylic cable with electrode holder 50 mm2 4 m 500A 43912063 Earth clamp cable 50 mm2 4 m 400 A For GPS 4000 C 43812219...

Страница 17: ...The aim of this switch is to protect the personnel from direct or indirect contact with electrical parts under voltage The differential circuit breaker is selected with a superior gauge to ID The conn...

Страница 18: ...Power supply cable I O I Master switch ON OFF M Adjustment lever of wire driving pressure K Drive motor N Polarity change system of torch Euro connector J Electrical connection cable of cooling module...

Страница 19: ...ect JOB number SETTING MODE It enables to change the cycle varia ble indicated on display D3 MMA TIG Welding intensity control P1 Welding PROCESS selection P2 MIG PROCESS Welding PROGRAM selection 2 E...

Страница 20: ...LSE PULSE MIG MIG SPOT MIG PULSE MIG Bi Pulse MIG SPOT PULSE MMA TIG TIG PULSE Software available Included Included OPTIONAL Ref 42370010 OPTIONAL Ref 42370011 OPTIONAL Ref 42370010 Included Included...

Страница 21: ...me 0 0 3 0 s 0 1 0 3 TPS Gas post flow time 0 0 5 0 s 0 1 0 4 REF Cooling unit mode OFF ON AUT OFF DIM Dimensional system mm in mm Restrictions mode 2T 4T 4TS 2T 4T 2T 4T 4TS 2T 4T 4TS 2T 2TS 4T IS In...

Страница 22: ...2 PARAMETERS SETTING MODE MMA PROCESSES P1 SELECT PROCESS P1 ENTER TO SETUP E1 SELECT CYCLE PARAMETER E2 ADJUST VALUE P1 SAVE PARAMETERS 2 2 PARAMETER RANGE UNIT RESOLUTION PARAMETER STD CEL HOT Hot S...

Страница 23: ...FF Restrictions mode VAL 2T 4T VAL 2T 4T TPR Gas pre flow time 0 0 5 0 s 0 1 0 3 IS Initial current 10 100 1 30 UPS Up Slope 0 0 10 0 s 0 1 0 4 IB Base Intensity 10 100 1 50 DCL Upper Intensity Bipuls...

Страница 24: ...shed the work do not disconnect the machine immediately wait until the inner cooling system has totally cooled it KEEP THE WELDING ACCESSORIES IN GOOD CONDITIONS FOR USE ONCE THE WELDING OPERATION HAS...

Страница 25: ...he equipment Review the power electrical connections ALTHOUGH THE MACHINE IS CONNECTED AND WITH THE SWITCH LD1 ON THERE IS NO REACTION WHEN PRESSED Failure of the pistol switch which does not make per...

Страница 26: ...ed down when it knocks against the piece The wire length at onset of welding process is too long Change in the settings menu the value of the burn back time correction Oxide or other polluting agents...

Страница 27: ...also occur with those materials which have some kind of surface coating zinc plated galvanised etc Avoid inhaling the fumes given off in the process at all times Protect yourself from the fumes and m...

Страница 28: ...se el producto y la factura de compra debidamente cumplimentada y sellado por un Servicio T cnico autorizado Los gastos de env o y transporte ser n a cargo del usuario Los da os o gastos imprevistos o...

Страница 29: ...R MA GR NE NE BL AM VE GR NE BL BL BL BL BL BL BL BL NE BL GR AZ BL BL BL BL NE BL GR AZ BL AM GR BL AM GR GR AM BL GR AM BL BL BL BL RO GR NE NE RO 1 FICHA 2V 2 NE GR MA AZ IDEN COLOR RO ROJO RED NE...

Страница 30: ...R MA GR NE NE BL AM VE GR NE BL BL BL BL BL BL BL BL NE BL GR AZ BL BL BL BL NE BL GR AZ BL AM GR BL AM GR GR AM BL GR AM BL BL BL BL RO GR NE NE RO 1 FICHA 2V 2 NE GR MA AZ IDEN COLOR RO ROJO RED NE...

Страница 31: ...FR JULIAN SIMON 25 PRES_F GND 2 1 CN13 M_FASE PRE_CAR 5V GND CN11 3 2 1 4 TERM1 AVSS TA3_B TERM3 CN8 3 2 1 4 TERM3 AVSS TA3_A TERM2 CN7 3 2 1 4 L_TENS POS N C N C CN5 3 2 1 4 VSH N C VSH CUR CN1 3 2 1...

Страница 32: ...REPUESTOS GPS 4000 C REF 423 84 000 17 5 17 HR 42384000 V1 1 2 PARTS LIST GPS 4000 C 3Ph 400V 50 60 Hz...

Страница 33: ...AL M H M4 25 mm 16 00315001 CIERRE DESLIZANTE 51 00552035 FUSIBLE REARMABLE 0 25A 17 42310010 TAPA CONEXI N WCS 52 42384016 PLACA ELECTR NICA DSP 18 42300006 LATERAL M VIL 53 00533003 SEPARADOR METAL...

Страница 34: ...REPUESTOS GPS 3000 C REF 423 85 000 17 5 17 HR 42385000 V1 1 2 PARTS LIST GPS 3000 C 3Ph 400V 50 60 Hz...

Страница 35: ...ETAL M H M4 25 mm 16 00315001 CIERRE DESLIZANTE 51 00552035 FUSIBLE REARMABLE 0 25A 17 42310010 TAPA CONEXI N WCS 52 42385016 PLACA ELECTR NICA DSP 18 42300006 LATERAL M VIL 53 00533003 SEPARADOR META...

Страница 36: ...RECTIFYING DIODE DIODE RECTIFICATIVE 3 552057 TERMICO DE 70 N C THERMAL DEVICE TERMIQUE DISPOSITIF 4 42312033 CJTO CONEXION UNION 4 DIODOS CONNECTION SET UNION 4 DIODES ENSEMBLE CONNECTION UNION 4 DIO...

Страница 37: ...IETE DCHA COMPLETO LEVER CLAMP RIGHT COMPLETE LEVIER DE BLOCAGE DROITE COMPLETE 7 42316720 PALANCA APRIETE IZDA COMPLETO LEVER CLAMP LEFT COMPLETE LEVIER DE BLOCAGE GAUCHE COMPLETE 8 42316820 SOPORTE...

Страница 38: ...ED ROULEAU DE PRESSION 2 1 42316129 RULETA D37B 1 0 1 2 MM ALU TWIN FEED ROLL STD WITH GEAR 1 0 1 2 ROULEAU D ALIMENTATION 1 0 1 2 2 2 42316130 RULETA D37B 1 2 1 6 MM ALU TWIN FEED ROLL STD WITH GEAR...

Страница 39: ...E EEC DIRECTIVES REQUIREMENTS OF THE EEC STANDARD D CLARA QUE LES PRODUITS PR SENT S ET R FERENC S DANS LE MANUEL D INSTRUCTION SONT CONFORMES AUX DIRECTIVES COMMUNAUTAIRES APPLICABLES POUR LE MARQUEE...

Страница 40: ...E Manual completo disponible en www galagar com EN Full manual available in www galagar com...

Отзывы: