5.2.10. CYCLE PARAMATERS –TIG AC PROCESS.
From this screen we will set the values that define the welding cycle. The cycle chart and the parameter selection table
(Table 4) will change depending on the selection of welding mode.
KEY
ACTION
DESCRIPTION
P1
Go to the source process
Confirm changes in case of modification request.
P2
Access to Operation Mode
Access the selected process mode.
P6
Restore factory settings
Recover original parameters settings.
E1
Select parameter
Selected parameter with white bar.
When navigating through the parameter selection table, the corresponding
segment of the upper cycle graph will light up simultaneously.
E2
Modify parameter
Each of the different cycles will be composed of different regulation parameters that will vary depending on the selected
operation mode:
TABLE 4 – TIG AC
Parameter DESCRIPTION
FUNCITION
OBSERVATIONS
UNIT
RESOLUTION
SHELL
CREATION
Creation tungsten tip
Make round tungsten to facilitate electri-
cal transmission.
ON/OFF
ON/OFF
Ø SHELL
Tungsten tip diameter
Set the size of tungsten tip
Millimeters
AUT - 0,1
TPR
Pre-gas time
It facilitates arc ignition.
Seconds
0,1
IS
Intensity start
Reduces priming cracks.
%
1
TIS
Intensity start time
Preheat material
Mode 2TS only
Seconds
0,1
UPS
Increase time
Reduces initial tension.
Seconds
0,1
IB
Base Intensity
Thermal reduction.
PULSE – BIPULSE only
%
1
Dcl
Duty cycle
Balance the pulse for thermal control.
%
1
TCP
Pulse fall time
Smoothes transition I
₂
-IB
Milliseconds
10
FHZ
Pulsed frequency
Set the pulse rate.
Herces
1
DWS
Down time
Reduces final tension.
Seconds
0,1
IE
Final intensity
Reduces crater cracks.
%
1
TIE
Final Intensity Time
Reduces crater size.
Mode 2TS only
Seconds
0,1
TPS
Post gas time
Prevents cord oxidation.
Seconds
0,1