GAGGIA CADORNA 04 TEST MODE & STEAM OUT
1/5
4.1. Test Mode & Steam Out
When the display turns ON, press the keyboard buttons in the order described below:
When the machine is in Test Mode appears a windows divided in several sectors:
Page 1: Entering page;
Page 2: Keyboard and display testing;
Page 3: Brewing Unit and microswitch testing;
Page 4: Hydraulic circuit testing;
Page 5: Grinder testing;
Page 6: Steam out perform.
The first row of each window is a title, the white sectors represents the functions (or loads) available to
activate or deactivate, the last row is used to show other info. When a function is enabled the corresponding
box becomes colored. The dotted sectors are used to show informations about the status of microswitch,
sensors or other variables.
The presence of symbol (^) into a sector indicate that no function is associated to.
In Test Mode all loads are initially disabled.
To activate a load press the corresponding button on keyboard, to deactivate press again the same button.
Other conditions for which a load may be switched off automatically without key presses are:
• If it is defined a working cycle, when this cycle ends (such as the grinder or brew unit)
•The achievement of 90°C for boiler
How to enter
Description
Activation of loads
CADORNA TEST MODE
user guide
nomeFile
Cadorna - Test mode
v0.0_ENG.doc
1.0
F.Bolognesi
04/06/2019
Page | 2
revNum
Redatto
SaveDate
Pagina/pagine
1 Test Mode
1.1 How to enter
When the display turns ON, press the keyboard buttons in the order described below:
Previous page
Next page
Exit
1.2 Description
When the machine is in Test Mode appears a windows divided in several sectors:
Page 1: Entering page;
Page 2: Keyboard and display testing;
Page 3: Brewing Unit and microswitch testing;
Page 4: Hydraulic circuit testing;
Page 5: Grinder testing;
Page 6: Steam out perform.
The first row of each window is a title, the white sectors represents the functions (or loads) available to
activate or deactivate, the last row is used to show other info. When a function is enabled the corresponding
box becomes colored. The dotted sectors are used to show informations about the status of microswitch,
sensors or other variables.
The presence of symbol (^) into a sector indicate that no function is associated to.
1.3 Activation of loads
In Test Mode all loads are initially disabled.
To activate a load press the corresponding button on keyboard, to deactivate press again the same button.
Other conditions for which a load may be switched off automatically without key presses are:
•
If it is defined a working cycle, when this cycle ends (such as the grinder or brew unit)
•
The achievement of 90°C for boiler
Содержание SUP 049
Страница 4: ...GAGGIA CADORNA CHAPTER 1 INTRODUCTION ...
Страница 7: ...GAGGIA CADORNA 01 INTRODUCTION 3 6 1 5 Electrical diagram ...
Страница 11: ...GAGGIA CADORNA CHAPTER 2 TECHNICAL SPECIFICATIONS ...
Страница 16: ...GAGGIA CADORNA CHAPTER 3 OPERATING LOGIC ...
Страница 23: ...GAGGIA CADORNA CHAPTER 4 TEST MODE AND STEAM OUT ...
Страница 29: ...GAGGIA CADORNA CHAPTER 5 ESPRESSO PHILIPS SERVICE CENTER ...
Страница 31: ...GAGGIA CADORNA CHAPTER 6 MACHINE REPAIR FLOW ...
Страница 33: ...GAGGIA CADORNA CHAPTER 7 DISASSEMBLY ...