SYmPtom

reSPonSe

action

Engine Overspeed

Do Not Crank. Apply DC power to the governor 
system.

After the actuator goes to full fuel,

 

disconnect the speed sensor at 

Pin 3. If the actuator is still at full fuel-speed then the controller is 
defective. 

Manually hold the engine at the desired running 
speed. Measure the DC voltage between Pins 
1(-) and 11(+) on the speed controller.

If the voltage reading is 1.0 to 2.0 V DC check for:

• 

Speed set above desired speed

• 

Possible defective speed controller

If voltage reading is > 2.0 V DC check for:

• 

Actuator binding

• 

Linkage binding

If the voltage reading is below 1.0 V DC check for Defective speed 
controller

Check Flywheel Teeth value.

Incorrect number of teeth in setup.

Overspeed shuts down 
engine after running 
speed is reached

Examine the Speed and Overspeed values for 

the engine

Speed set too high.
Overspeed set too close to Speed.
Actuator or linkage binding.
Speed controller defective.

Overspeed shuts down 
engine before running 
speed is reached

Check resistance between Pin 3 and Ground. 

Should be 30 to 1200 Ω. See your specific Mag

-

netic Pick-up data for resistance details.

Overspeed set too low
If the speed sensor signal is erroneous, then check the wiring.

Actuator does not ener-
gize fully

Measure the voltage at the battery while cranking. If the voltage is less than: 

• 

7 V DC for a 12 V DC system, or 14 V DC for a 24 V DC sys-
tem check or replace battery.

Momentarily connect Pins 1 and 11. The actuator 
should move to the full fuel position.

Actuator or battery wiring in error
Actuator or linkage binding
Defective actuator
Fuse opens. Check for short in actuator or harness.

Engine remains below 

desired governed speed

Measure the actuator output, Pins 1 and 2, while 

running under governor control.

If voltage measurement is within 2 V DC of the battery supply 

voltage level, then fuel control is restricted from reaching full fuel 

position, possibly due to mechanical governor, carburetor spring, or 

linkage interference.

Speed set too low

EEG7000 SYSTEm TROUBlEShOOTING  (CONTINUED)

17

Use the Windows Device Manager to determine the correct serial port for EEG7000:

1. 

In your Windows search box type Device Manager.

2.  Locate the Ports (COM & LPT) item.

3. 

Expand it to see the com ports listed. Select the USB Serial Port. 

 UnSatiSfactorY Performance

 DetermininG YoUr Serial Port

SYmPtom

reSPonSe

action

GAConfig Tool not dis

-

playing some parameters

Some older EEG7000 units may not have firmware 

compatible with the new software. 

1. Install the 

Interface Tool

 created for the EEG7000. 

2. See your GAC representative for firmware update details. 

Error installing GAConfig 

Tool

Some older EEG7000 units may not have firmware 

compatible with the new software. 

1. Install the 

Interface Tool

 created for the EEG7000. 

2. See your GAC representative for firmware update details. 

 otHer iSSUeS

Содержание EEG7000

Страница 1: ...off road mobile equipment GAConfig Tool adds the ability to monitor and set parameters from your PC With CAN J1939 capabilities allow it to accept TSC1 messages over USB as a mini engine control modul...

Страница 2: ...cause personal injury or equipment damage Do not rely exclusively on the governor system electric actuator to prevent overspeed A secondary shutoff device such as a fuel solenoid must be used LED DEFI...

Страница 3: ...C or 4 20 mA selectable polarity 10 Battery Ground 16 Battery ground 11 Battery Power 16 A 10 A fuse must be installed in the positive battery lead to protect against any overload or short circuit or...

Страница 4: ...cable shield must only be connected to the case The shield should be insulated to ensure that no other part of it comes into contact with engine ground otherwise stray signals may be introduced into t...

Страница 5: ...lue and click Calibrate Minimum button To calibrate the maximum percent set the potentiometer to the highest end value and click Calibrate Maximum button The difference between the analog minimum spee...

Страница 6: ...ntiometer CW all the way and click Calibrate Maximum d Note the Input Actual result Variable Speed can be used as another fixed speed setting if both Speed Minimum and Speed Maximum parameters are set...

Страница 7: ...e please cal your GAC representative The default installation is in the Program Files x86 Governors America Corporation file area 3 The GAConfig Setup screen displays Click Install The Installing GACo...

Страница 8: ...RED warning boxes error information yellow cautions and other pop up information Setting some parameter values impact other parameter values often displaying a caution The GAConfig Tool windows autom...

Страница 9: ...NG Engine Tuning is the basic menu used to store your engine startup and tuning information Flywheel teeth overspeed fuel limit Start fuel rate Fuel ramp rate starter cutoff acceleration and decelerat...

Страница 10: ...uning improves performance Before you start your engine Install the GAConfig Tool on a PC and connect the PC to the EEG7000 with the USB cable Provide power to the EEG7000 from the battery Install an...

Страница 11: ...until instability develops Gradually decrease Stability value until stability returns Decrease the value by one to ensure it is stable If there is no instability leave set at 50 c Set the DEADTIME to...

Страница 12: ...speed while in variable speed Speed Maximum 150 6000 rpm 1500 Maximum speed setting Variable Speed End Gain 1 100 50 Gain to use when at the maximum speed while in variable speed Input Minimum Calibra...

Страница 13: ...y adding settings or use the automatic calibration buttons a To set calibration automatically Turn potentiometer fully CCW and click Calibrate Minimum Turn potentiometer fully CW and click Calibrate M...

Страница 14: ...le speed as needed The No Load Current value must be set to less than Full Load Current and the difference between the two must be at least 0 5 A If an invalid combination is entered a warning message...

Страница 15: ...econds 3 Click Start The data displays similar to shown below Note the time and rpm display when you move your cursor over the green timeline 4 To save the data click Save The file is saved as a print...

Страница 16: ...1500 1500 Set engine speeds Variable Speed Variable Speed Input Mode 4 20 mA or 0 5 V DC 0 5 V DC Sets variable speed input signal to 0 5 V DC or 4 20 mA Speed Minimum Speed Maximum 150 6000 150 6000...

Страница 17: ...orporate while in variable speed mode SAE J1939 Configuration J1939 Address 0 253 0 Sets the CAN address for J1939 communication Engine Requested Torque Speed 0 6000 rpm 1500 The value the controller...

Страница 18: ...39 compatible After initial configuration the CAN data is available on the J1939 Diagnostics Messages view on the GAConfig Tool or using a compatible controller Sample PGN transmit and receive codes a...

Страница 19: ...d diagnostics CONTINUED 15 PGN NAME VALID SPN s NOTES 0 Torque Speed Control 1 TSC1 SPN695 Engine Override Control Mode SPN898 Engine Requested Speed Speed Limit SPN3349 TSC1 Transmission Rate SPN4206...

Страница 20: ...0 offers a number of GAC specific capabilities as well as helpful tools The GAConfig Tool allows settings in the tool to be stored shared and imported back into the tool for use on multiple EEG7000 co...

Страница 21: ...tic Engine Behavior Increasing Stability reduces instability but does not totally correct it If this is the case there is most likely a problem with the engine itself Check for engine mis firings erra...

Страница 22: ...sure the voltage at the battery while cranking If the voltage is less than 7 V DC for a 12 V DC system or 14 V DC for a 24 V DC sys tem check or replace battery Momentarily connect Pins 1 and 11 The a...

Отзывы: