6
4.2 UNPACKING & CONTENTS
- Wall bracket with template.
- Boiler.
- Documentation.
- Bags with parts and fittings.
Dispose of the cardboard packaging at a cardboard recycling site. Observe national regulations.
4.3 LOCATION
WARNING
INSTALL UPRIGHT ON A WALL SUITABLE TO SUPPORT THE TOTAL WEIGHT OF THE
BOILER WHEN FULL OF WATER
–
125 kg.
The location should be clean and dry with no presence of gases, explosives or
flammable objects.
It is not suitable for installation outside and should be protected from moisture
and frost.
The boiler must be sited so that the boiler and controls are not accessible to any
persons whilst using a bath or shower and there should be no possibility of water
dripping or splashing onto the boiler or controls.
Electrical safety regulations for clearances must be followed if installed in a
bathroom or shower area.
The boiler has an electric protection rating of IP20/IP2X.
Where possible the boiler should be sited to minimize the pipe distance to hot
water outlets.
The power supply cable should be carefully routed and secured and provision
made for a suitable isolation switch and MCB/RCD.
4.4 DIMENSIONS & CONNECTIONS
i
A Safety valve drain DHW.
B Electrical connection
C
Cold water input ½”
D
DHW outlet ½”
E
Heating return ¾”
F
Heating flow ¾”