32
8 MAIN COMPONENTS LIST
9 MAINTENANCE & CARE
Gabarron MATTIRA electric combi boilers will require an annual maintenance check to ensure preservation of the
manufacturer's warranty and a prolonged and trouble-free life. A full check list and service log is located at the back of this
manual which, should be adhered to. The following points below should also be constantly observed:
-Check and maintain the heating system pressure between 1 & 1.5 bar when cold. Frequent re-filling of the system could
cause scaling and corrosion and should be avoided. Regular pressure loss could indicate a leak and should be investigated
promptly.
CAUTION
–
Under no circumstances should the boiler be switched on when the system is dry.
CAUTION - Never start the boiler when the DHW tank is empty; to fill it for the first time open a hot water tap
and wait until water comes out of it.
- Keep the ventilation openings on the boiler clear to ensure correct operation and protect from overheating. Do not place
or store objects on the boiler.
- Protect against freezing by ensuring power is maintained to the boiler at all times, unless the water supply is interrupted or
the heating system is empty. In dwellings, frequently un-occupied or at risk of freezing, an appropriate anti-freeze can be
added to the heating system at a concentration of not more than 30% by volume. Otherwise it is recommended to isolate
the power and completely drain the heating and hot water systems.
- The outer case can be cleaned with a damp cloth having first isolated the boiler from the mains. Do not use solvents or
abrasive cleaners.
10 ENVIRONMENTAL INFORMATION
Gabarrón boilers are manufactured within a certified environmental management system. From the design stage, all the
production phases are performed taking into account the most rigorous environmental requirements. For example, the
selection of materials involves guaranteeing their biodegradability, re-use and recycling.
When this boiler’s long, useful life is over; it must be handed in to an electrical equipment collection point for proper
recycling. By ensuring that this product is correctly disposed of, you will help to avoid any possible negative effects on the
environment and public health that could occur if this product is not properly handled. To obtain more detailed information
on the recycling of this product, contact your local authority, your waste disposal service or the shop where you purchased
the product.
These regulations only apply in EU member countries.
Heating expansion vessel 6L
ref. 60091510
DHW. expansion vessel 3L
ref. 60105580
DHW. expansion vessel hose MAC
ref. 60101950
50 L DHW. insulated tank
ref. 60105560
Insulated heating header tank
ref. 60101700
Circulation pump RKC130
ref. 60190076
Main electronic PCB MAC
ref. 60105585
Power PCB MAC with support
ref. 60105595
Temperature sensor white
ref. 60105600
Temperature sensor black
ref. 60105605
15 kW heating resistance & joint 140
ref. 60100750
15 kW DHW. resistance & joint
ref. 60100700
DHW. resistance joint
ref. 60105670
Heating resistance joint
ref. 60091090
¾” hea
ting flow detector
ref. 60100805
0-4 bar pressure gauge
ref. 60100820
100°C thermal limiter
ref. 60101860
80°C thermal limiter
ref. 60101870
Automatic purge
ref. 60091280
3 bar central heating relief valve
ref. 60100840
7 bar DHW. P&T relief valve
ref. 60105660
½
” filling / shut off valve
ref. 60105686
Keyboard MAC
ref. 60105555
Содержание MATTIRA MAC15B
Страница 36: ...36 14 WIRING DIAGRAMS ...