background image

 

 

…unless these instructions are followed. 

 

 

Your new Turbo Tank Flusher is covered against factory defects by a limited 90-day warranty from the date of 

invoice.  This warranty does not apply to any products damaged by improper installation, shipping accidents, 

misuse, alteration or repairs not performed or authorized by G-TEC.              

 

 

The following instructions MUST ALWAYS be followed: 

 

 

NEVER plug the flusher into a wall outlet that has any other 110 volt appliances using that 

circuit including but not limited to light fixtures, drop lights, extensions cords, etc. 

 

 

 

ALWAYS check the position of the fluid purge valve before operating the flusher to prevent 

fluid spills.

 

 

 

Before starting or engaging the motor for flushing and purging, be CERTAIN that the ATF in 

the tank has reached ABOVE 150 degrees. 

 

 

If the RED INDICATOR LIGHT is 

on

, the ATF level is 

too low

 in the tank and the heater WILL NOT 

HEAT.  Refill the tank. 

 

 

Heater is adjustable; however, doing so is solely at the risk and responsibility of the operator.  Adjusting 

to a higher heat is only recommended on a per need basis.  After each high temperature job, the heater 

should be turned back to the factory setting of approx. 150-160°.  Never leave the heater adjusted to a 

high temperature!   

 

 

If the temperature ever exceeds 198 degrees, the float is designed to melt causing permanent loss of 

power to the heater until the float is replaced.   

 

 

The Baldor Motor/Viking Pump is equipped with a Watts Pressure Relief Valve.  The factory setting is 

between 100-125 psi.  You must never raise the psi higher than 125 as this will cause damage to the 

motor and pump.

 

 

 

G-Tec’s complete warranty and all liabilities are VOID if mineral spirits or petroleum-based 

solvents are used in your Turbo Tank Flusher!  

 

 

 

 

 

       

 

 

 

 

 

 

 

 

 

 

 

 

This unit will not work… 

Disclaimer 

 

G-TEC is not responsible for any damages to the flusher or to the customer’s facility or to operators when the 

instructions and warnings are not followed or heeded.  All repairs or replacements will be at the customer’s expense. 

 

 

Содержание Basic TTCF-6

Страница 1: ...D Deluxe TTCF 7AR Supreme TTCF HD Heavy Duty Heated Cooler Line Flusher Not all options available on all models TTCF 7AR shown below G TEC Inc 611 Kathryn St PO Box 1079 Nixa MO 65714 800 725 6499 417 725 6400 Fax 417 725 3577 www g tec com ...

Страница 2: ...the tank Heater is adjustable however doing so is solely at the risk and responsibility of the operator Adjusting to a higher heat is only recommended on a per need basis After each high temperature job the heater should be turned back to the factory setting of approx 150 160 Never leave the heater adjusted to a high temperature If the temperature ever exceeds 198 degrees the float is designed to ...

Страница 3: ...it 3 Install the appropriate quick disconnect line adapters imports or domestic to the ATF cooler inlet and outlet lines using any of the three methods in Picture 1 To forward flushing only Connect the red pressure hose to the cooler inlet line the line going to the external filter Connect the blue return hose to the cooler outlet line the line coming from the vehicle s cooler tank going to the tr...

Страница 4: ...t possible set the 7AR reverse lever to the 1 position for a forward flush 9 Cycle on the motor toggle Let the machine flush for 15 minutes Regulate air supply to 90 100 psi 10 While the machine is running open the air purge valve for 10 15 seconds to cause agitation and improve the flushing process Then close the air purge valve for 5 minutes Repeat the opening and closing 3 times 11 Cycle off th...

Страница 5: ...open for at least 15 seconds to purge the lines of residual ATF then close the air purge valve 14 Remove both spin on filters install the filter screens on top of the filters and spin the filters back in place on the flusher Backflush if possible the flusher for 5 minutes Cycle off the motor Check the filter screens If no debris is present toggle off the motor Then air purge the lines for 15 secon...

Страница 6: ... 4 Frequently monitor the temperature of the fluid using the thermometer during the high heat job making sure the temperature does not exceed 199 5 After completing the high heat job the temperature must be returned to factory settings of 150 160 by turning the rubber tip counter clockwise 6 NEVER leave the heater in the high heat position damage may occur to the machine When the white arrow on to...

Страница 7: ...r s drain plug After cleaning refill the tank with 8 9 gallons of clean ATF and as a option you can add one 11 oz bottle of transmission flush Troubleshooting Always unplug the flusher before any troubleshooting Problem No Heat Red Light On Solution 1 Make sure the fluid level is above the float switch or 3 4 from the top of the fill neck 2 If you still have no heat test for 110 V at the heater 3 ...

Страница 8: ...turn hoses with the provided coupling so that fluid circulates through the flusher only 4 Increase the heat slightly Problem Shop s Circuit Breaker Tripping Thermal Switch On Motor Tripping Solution 1 Clear entire flushing system of debris Check for restrictions from motor to hoses to connectors etc 2 Make sure the flusher is plugged into a 110 V 20amp outlet with NOTHING else plugged into it 3 Ma...

Страница 9: ...ter Bracket Magnetic Spin On Non By Pass Filters Heater Kit Baldor Viking Pump Motor Complete Hose Kit for All Flusher Hoses Manual Handheld Air Purge w Venting Cap Long Handle with Hose Hooks Hose Holding and Tool Tray Holding Bracket Spin On Filter Cross Reference Guide KEEP FOR FUTURE REFERENCE Filter G Tec AC Fram Super Tech Motorcraft STP Non By Pass NBP2 PF34 PF1232 PH3682 ST2827 FL13B FL839...

Страница 10: ...event damage To ship by UPS use the 611 Kathryn St address To mail by US Post Office use the P O Box 1079 Include the RGA number on the outside of the package 3 We will repair replace the product and ship it back On items covered under warranty G Tec will determine whether to repair or to replace the defective item s at no charge Item s will be shipped back to customer at G Tec s expense However i...

Страница 11: ...ntained herein shall create a warranty for customer s items used in conjunction with Turbo Tank Products or for said equipment Further this warranty shall not extend to any normal wear or usage of the equipment or if the equipment has been improperly installed This warranty is in lieu of any other warranty either expressed or implied Neither G TEC nor Turbo Tank Products is liable for any damage w...

Отзывы: