G.T.Power E6D Скачать руководство пользователя страница 20

The  output  is  connected  to  a  battery  with  incorrect 
polarity.

This  will  be  displayed  in  case  of  detecting  an 
interruption  of  the  connection  between  battery  and 
output  or  voluntarily  disconnecting  the  charge  lead 
during the operation.

The  cell-count  of  Lithium  battery  pack  was  selected 
incorrectly. Verify the cell-count carefully.

There happens the malfunction at the charger circuit 
by  any  reason.  The  charger  should  be  repaired  at 
the factory.

There  is  a  short-circuit  at  output.  Please  check  the 
charging leads or output cable of battery pack.

The  charger  detects  the  voltage  is  lower  than  you 
set  at  Lithium  program.  Please  check  the  cell-count 
of the battery pack.

The  charge  detects  the  voltage  is  higher  than  you 
set  at  Lithium  program.  Please  check  the  cell-count 
of the battery pack.

The  balancing  circuit  had  been  damaged.  The 
balance  function  can  not  be  used,  and  the  charger 
needs to be repaired at our factory.

The  voltage  of  one  of  the  cell  in  the  Lithium  battery 
pack  is  too  low.  Please  check  the  voltage  of  cells 
one by one.

The  voltage  of  one  of  the  cell  in  the  Lithium  battery 
pack  is  too  high.  Please  check  the  voltage  of  cells 
one by one.

There  are  bad  connection  at  the  individual 
connector.  Please  check  the  connector  and  cables 
carefully.

The  charger  cannot  read  out  the  individual  voltage 
correctly  because  of  malfunction  of  main  processor. 
The charger needs to be repaired.

The voltage of input power drops below the limit.

Check connection ---
Reversed polarity

STOP/ESC

STOP/ESC

Check connection ---
Connection break

Check cell-count ---
Incorrect cell-count 

Check charger ---
Break-down

Check connection ---
Short-circuit

Check battery ---
Low voltage

Check battery ---
High voltage

Check balancer ---
Comm. Error

Balance error ---
Low cell vol.

Balance error ---
High cell vol.

Balance error ---
Bad connection

Balance error ---
Ref. Data fail

Check power ---
Low input volt

Manual of the charger E6D

18

Содержание E6D

Страница 1: ...ed high performance rapid charger discharger for NiCd NiMH Lithium Pb batteries Dual input power 50W AC 90W DC temperature sensor and integrated Lithium battery balancer Charger current 0 1 6 A Discharger current 0 1 1 A LiPo LiFe Lilo 1 6 series NiCd NiMH 1 15 cells Pb Lead acid 2 22 V ...

Страница 2: ...e process 10 8 NiMH NiCd battery program 11 8 1 Parameter set up for NiCd NiMH battery 11 8 2 Select program and start the process 13 9 Pb Lead acid battery program 14 9 1 Parameter set up for Pb battery 14 9 2 Select program and start the process 15 10 Screen displays during process 15 11 Review the date after finishing the progress 16 12 Warning and error messages 17 13 Battery status view 19 14...

Страница 3: ...vity The automatic charge termination program works on the principle of the Delta peak voltage detection NiCd NiMH Auto charge current limit When charging NiCd or NiMH at AUTO current mode you can set the upper limit of charge current to avoid from feeding high current to the battery This is very useful when charging the low impedance and small capacity NiMH battery in AUTO model Capacity limit Th...

Страница 4: ...ror message Returns to the previous screen Temperature sensor port Connect the temperature sensor to this port to monitor the battery temperature Never leave the charge unsupervised when it is connected to its power supply If any malfunction is observed terminate the process immediately and refer to the operating instructions Keep away the unit from dust damp rain heat direct sunshine and vibratio...

Страница 5: ...e cut off level 0 85V cell NiCd 1 0V cell NiMH Lilo voltage level 3 6V cell max charge voltage 4 1V cell allowable fast charge current 1C or less min discharge voltage cut off level 2 5V cell or higher LiPo voltage level 3 7V cell max charge voltage 4 2V cell allowable fast charge current 1C or less discharge voltage cut off level 3 0 V cell or higher LiFe voltage level 3 3V cell max charge voltag...

Страница 6: ...which is already fully charged or just slightly discharged Non rechargeable batteries Explosion hazard Batteries that require a different charge technique from NiCd NiMH Lilo LiPo LiFe or Pb Faulty or damaged battery Battery fitted with an integral charge circuit or a protection circuit Batteries installed in a device or which are electrically linked to other components Batteries that are not expr...

Страница 7: ...f 1 60min Safety temperature 20 80C Safety timer 10 9990 min Maximum capacity 50 120 Charge current 0 1 6 0A Discharge current 0 1 1 0A Charge volt Default 2 2 2 5V cell Discharge volt Default 1 4 1 8V cell End Current Auto 60 500mA Trickle current Off 50 300mA Safety temperature 20 80C Safety timer 10 9990min Maximum Capacity 50 120 INC DEC INC DEC UP DOWN User Setup PROGRAM Data View Battery Sta...

Страница 8: ...the password 5 The first display When you connect the crocodile clips which attached to the charger as a input power cable to a suitable 12V DC power source or AC power cord to the wall socket the start up display appears Thus the power on process has been completed The display shows the brand name and device name as well as user s name The default display for user s name is E6D but you can revise...

Страница 9: ...brightness of LCD screen when LCD Light is on Factory setup Restore all values to the default which was done at our factory To do this you need to enter the password The way of entering the password is described on Password mode at next step When you perform this program successfully all the data will returnto their default values including the password 0000 It will take several seconds to initial...

Страница 10: ...ith the battery Use UP or DOWN button to scroll up and down the menu and change the value by using INC or DEC button To start the process press and hold ENTER button for more than 3 seconds regardless of cursor position Chg current Set the charge current 0 1A 6 0A Dchg current Set the discharge current The value may not exceed 1C for a maximum safety 0 1 1 0A Dchg voltage Set the final voltage per...

Страница 11: ...attery Safety temp This is a feature using temperature probe contacting the surface of battery which can monitor the temperature of battery The recommended maximum temperatures are 45 55C 113 130F for NiCd 43 52C 110 125F for NiMH and 32 35C 90 95F for Lithium Once the battery reaches this temperature during the process the program will be terminated forcibly to protect the battery If the battery ...

Страница 12: ... voltage of battery at its initial stage is over the voltage level to storage the program will start to discharge Charge Fast The charging current is getting smaller as the process goes to the near end term of Lithium battery charging To finish charging process earlier this program eliminate certain term of CV process Actually the charging current will goes to 1 5 from the initial value to end the...

Страница 13: ... menu The cell count and capacity need to be matched with the battery Use UP or DOWN button to scroll up and down the menu and change the value by using INC or DEC button To start the process press and hold ENTER button for more than 3 seconds regardless of cursor position Chg current Set the charge current 0 1 6 0A Dchg current Set the discharge current The value may not exceed 1C for a maximum s...

Страница 14: ...t will be decreased until the designated value has been reached Trickle curr Activate or deactivate the trickle charge after the termination of process Off 50 300mA Peak delay This restrains the delta peak voltage detection until the time has reached This prevents a premature cut off from the battery of high internal resistance The default value is one minute 1 15 minutes No cycles The number of c...

Страница 15: ... per cell CV mode When the voltage has been dropped to the final discharge voltage the discharger job will continue until the end current which has been set at End current has been reached with decreasing discharge current gradually For maximum discharge use this mode Cycle mode You can use this function for balancing refreshing and break in the battery All of charging and discharging parameters w...

Страница 16: ...capacity need to be matched with the battery Use UP or DOWN button to scroll up and down the menu and change the value by using INC or DEC button To start the process press and hold ENTER button for more than 3 seconds regardless of cursor position Chg current Set the charge current 0 1 6 0A Dchg current Set the discharge current The value may not exceed 1C for maximum safety 0 1 1 0A Chg voltage ...

Страница 17: ...s 9 2 Select program and start the process Charge mode Set the charge mode which the charger will work with Normal The charger will work with the parameters which were set at the screen The feeding current will be zero at every 90 seconds to have 6 seconds of waste time for higher charging efficiency Pulse The charger will work with the parameters which were set at the screen The feeding current w...

Страница 18: ...l voltages The display shows the voltage of individual cells during charging Lixx battery To show the voltages the balance adaptor should be linked to the balance port of charger with connecting the balance tab of battery pack After finishing the program you can review the date which had been pertained to the input and output of the charger by selecting DATE VIEW menu at the main screen These date...

Страница 19: ...he display Pressing INC or DEC button will scroll the display up and down Charge data is marked by C and discharge data is marked by D The display shows the final voltage of individual cells when the balance tab was connected to the individual port of charger during the progress of Lixx battery UP DOWN UP DOWN DAT GRP CEL CYE 1 C 00000mAh 0 00V D 00000mAh 0 00V 2 C 00000mAh 0 00V D 00000mAh 0 00V ...

Страница 20: ...alance function can not be used and the charger needs to be repaired at our factory The voltage of one of the cell in the Lithium battery pack is too low Please check the voltage of cells one by one The voltage of one of the cell in the Lithium battery pack is too high Please check the voltage of cells one by one There are bad connection at the individual connector Please check the connector and c...

Страница 21: ...city which is defined as how much current a battery can supply constantly over one hour of time Most hobby batteries are rated for capacity in Ah or milliampere hours A 650mA battery can delivery 650mA of current for one hour 650A 1hr 60Ah Nominal voltage V The nominal voltage of the battery pack can be determined as follows NiCd or NiMH multiply the total number of cells in the pack by 1 2A 8 cel...

Страница 22: ...for Lixx Weight 750g Dimensions 155x140x60mm 16 Warranty and service We warrant this product for a period of one year 12 months from the date of purchase The guarantee applies only to such material or operational defects which are present at the time of purchasing the product During that period we will repair or replace without service charge any product deemed defective due to those causes Any re...

Отзывы: