Input vol:
DC voltage at the charger's input lead.
Battery vol:
DC voltage of battery at the end of
process.
Ext temp:
The temperature of battery as measured
with temperature sensor connected to temperature
sensor port of charger at the end of process.
Dhg time:
The total elapsed of time needed to
complete the charge progress.
Dchg time:
The total amount of time needed to
complete the discharge progress.
Capacity:
The total amount of charged or
discharged capacity during whole process.
The graph shows the voltage curves in Y-axis along
with the time in X-axis, after the process has
finished.
The display shows the battery's capacity and peak
voltage reading for each charge and discharge
period for up to 10 cycles. The cycle number is show
on the left side of the display. Pressing 'INC' or
'DEC' button will scroll the display up and down.
Charge data is marked by 'C' and discharge data is
marked by 'D'.
The display shows the final voltage of individual
cells, when the balance tab was connected to the
individual port of charger during the progress of Lixx
battery.
UP DOWN
UP DOWN
DAT GRP
CEL
CYE
1 C 00000mAh 0.00V
D 00000mAh 0.00V
2 C 00000mAh 0.00V
D 00000mAh 0.00V
UP DOWN
Input vol: 12.35V
Battery vol: 10.54V
Ext temp: 42C
Chg time: 52min
Dchg time: 0min
Capacity: 898mAh
DAT
GRP CYE CEL
DAT
CYE CEL
GRP
No Capacity Voltage
12. Warning and error messages
E6D incorporates a various functions of protective and monitoring the system to verify
functions and the state of its electronics. In any case of occurring error, the screen displays
the cause of error that is self-explanatory with audible sound.
Manual of the charger E6D
17
DAT GRP CYE
CEL
C1: 4.20V C2: 4.20V
C3: 4.20V C4: 0.00V
C5: 0.00V C6: 0.00V
HIGH VOL: 4.20V
LOW VOL: 4.20V