LiPo CHARGE
5.2A 11.1V(3S)
R: 3SER S: 3SER
CONFIRM(ENTER)
R: 3SER S: 3SER
CONFIRM(ENTER)
SET INPUT BATT
Pb 14.7V(6P)
LiPo FB-DIS
3.5A 11.1V(3S)
The second line left side to set charge current value, right
side to set the battery pack voltage value. After done, press
and hold Start/Enter for 3 seconds to start the program.
(
charge current
:
0.1
~
12.0A,cell voltage
:
1
~
6cells
)
Press ENTER to start program.
Set battery type and voltage value, then press and hold
Start/Enter for 3 seconds to start the program.
You have to use this mode under DC working status and input port connected to battery,
otherwise will report an error. FB-DIS working principle is transmit the standby discharging
battery capacity to input battery through the charger and acheived the discharge effect. For
your safety, the screen shows discharge current should not exceed the battery manufacturer
allowed maximum discharge current value, rated voltage should not exceed the battery
manufacturer allowed lowest voltage value, in case deep discharge.
7.5 LiPo FB-DIS mode
The second line left side to set charge current value, right
side to set the battery pack voltage value. After done, press
and hold Start/Enter for 3 seconds to start the program.
(
charge current
:
0.1
~
12.0A,cell voltage
:
1
~
6cells
)
It shows your set cell counts and charger detected cell
counts.
R:
shows the charger detected cell counts,
S:
shows
cell counts you selected in you last menu, if the value is the
same, press Start/Enter to start charge. If S and R value not
the same, press Batt type/Stop back to last menu and check
clear cell counts before charging.
It should connect the battery to the input connector and also connect the balance
connector when charge.
7.6 Charging Lithium battery in balance mode