Original Bedienungsanleitung FUXTEC FX-MT152/-MT152E/-MT252_de_en_fr_ita_rev18
97
9. Store the device in a cool, dry place away from any ignition source such as an oil
burner, water heater, etc.
TRANSPORT PROTECTION
Make sure that the device is well-secured during transport to avoid fuel loss, damage, or
injury. Install transport protection for metal sheets during transport and storage
Troubleshooting
1. Difficulties during commissioning
Situation
Cause
Solution
No ignition
spark
Spark plug
Carbon deposit between the
diodes of the spark plug
Clean the spark plug.
Adjust the gap
0.6~0.7mm, Replace
the spark plug
other
ignition coil defective flywheel
magnet too weak
Replacing the ignition
coil or flywheel
Weak
ignition
spark
Compression
Too much gasoline in the
combustion chamber, bad fuel or
water in the tank
Remove the spark
plug and allow to dry,
replace fuel.
The carburetor does
not pump oil
anymore.
Oil line blocked
Cleaning the
carburetor and
cleaning the pipes
regular oil supply
but weak
compression
Piston rings worn, spark plug not
screwed down, cylinder head not
tight wrong valve clearance or
ignition timing.
Replace screw tight
replace or adjust
Regular oil supply
and proper ignition
spark
Poor contact between ignition cap
and spark plug
Replace or check