MCT-MC
4.3
Logging
- 91 -
FDC MCT-MC
The DataWeb interface does not transfer complete files for backup like the FTP and FileWeb interfaces. The
DataWeb interface transfers records in real time based on the log setup interval at the MC. When logging is
started at the MC, data will begin transfer to the server side site. Data will be transferred to the server at the
beginning of logging (one record) with additional records transferred based on the rate that the MC data log
interval is set for.
If the data log interval rate is set for 60 seconds, the MC will populate the database with a single set of records
(PV, SP, %Out determined by data log/server setup) once every 60 seconds. If the data log interval rate is set
for 120 seconds, the MC will populate the database with a single set of records (PV, SP, %Out determined by
data log/server setup) once every 120 seconds. Data log intervals can be set as fast a 1 second since buffering
is used at the MC for faster data log rates, but in this case the database would receive a total of 60 records
once per minute (one record per second). Buffering for rates faster than 1 minute is used to reduce
access/overhead at the server side while still maintaining 1 second date/time stamps for database record
keeping.
8.5.2 FileWeb/DataWeb Server Components and Requirements.
While the actual server side development is more involved than this manual will cover, component overview
and installation is covered in section A.2 of the Appendix.
Web Development Support:
Future Design Controls does not support or develop custom server side web solutions. We can offer 3rd party
resources to assist customers in these development requirements.
Содержание MCT-MC 4.3
Страница 1: ...MCT MC 4 3 User Manual MCT MC 4 3 User Manual Rev A February 2018...
Страница 175: ...MCT MC4 3 Appendix 175 FDC MCT MC A 5 Power Supply Specifications DIN Rail Mount Power Supply Specifications...
Страница 176: ...MCT MC4 3 FDC MCT MC 176 Appendix...
Страница 177: ...MCT MC4 3 Appendix 177 FDC MCT MC Open Frame Power Supply Specifications...
Страница 178: ...MCT MC4 3 FDC MCT MC 178 Appendix...
Страница 179: ...MCT MC4 3 Appendix 179 FDC MCT MC A 6 Power On Delay Relay Specifications GE1A C10HA110...
Страница 180: ...MCT MC4 3 FDC MCT MC 180 Appendix...