CHARS 3 & 4 - COMMANDS AND SUBCOMMANDS
The examples below use a default address of 1 following the “*“. Substitute the desired
address from the above table of Serial Comm Address Codes. All command sequences shown
must terminate with <CR>, followed by an optional <LF>.
COMMUNICATIONS MODE
Continuous mode
*1A0
Command mode
*1A1
REQUEST DPM VALUES
Get reading**
*1B1
Peak reading
*1B2
Valley reading
*1B3
** The meter transmits the value or values selected in Ser 3.
REQUEST SCALE METER VALUES
Get reading**
*1B1
Peak only
*1B2
Net only
*1B3
Gross only
*1B4
Valley only
*1B5
** The meter transmits the value or values selected in Ser 3.