40
Common function
Function
Method
① Call the menu screen from the
home screen by pressing the
+ key
for 1 second.
+
② Select
from the menu with the
Jog
key
.
③ Open the setting screen by
pressing the
Jog key
.
(1 second)
Calling the setting screen
Model select(SELECT)
The model data of up to 30 models can be stored in the transmitter. This function is used when
calling saved model data.
Model copy(COPY)
This is the model data copy function. It is convenient when you want to store model data as backup
or build a number of models with the same data settings.
● The data of the model memory currently in use can be copied to another model memory.
Data reset (RESET)
The model data currently in use can be reset to its initial value. However, it does not Reset other
than the following of a
parameter
.
[ The function reset in a parameter :
ATL trim, TELEMETRY mode, STK POSI ALRM
]
Receiver selection(RX)
The R3008SB supplied with the transmitter, employs the T-FHSS Air system. When you want to use
an S-FHSS receiver, switch to S-FHSS here. However, the telemetry function cannot be used with the
S-FHSS system.
Link(LINK)
When linking with the receiver, the transmitter is set to the link mode here. The ID number of the
currently linked receiver is displayed.
"MDL-SEL"
MDL-SEL
Model select(select / copy / reset / RX type / link)
(Common)
Model select
Model copy
Data reset
RX system
Link
(Model number:1 〜 30)
● Original data : Model type
Model name
● Copy place : Model type Model
name
● System(T-FHSS Air or S-FHSS)
● Link receiver ID
● Select the setting
item with the
Jog
key
.
This function is used when calling and copying
model data stored in the transmitter. The selected
model data can also be reset. System changes
(T-FHSS Air, S-FHSS) matched to the receiver type
and linking with the receiver are also done here.
MDL-SEL
SELE▶ 1 MODEL-0001
COPY▶ 1 MODEL-0001
REST▶ Execute
RX▶ T-FHSS Air
LINK▶
ID=
XXXXXXXXX