83
Common function
Function
SENSOR
Sensor Slot
(Common)
This screen registers the telemetry sensors used
with the transmitter. When only one of a certain
type of sensor is used, this setting is unnecessary
and the sensor can be used by simply connecting it
to the S.BUS2 port of the transmitter.
When using 2 or more of the same kind of
sensor, they must be registered here.
[What is a slot?]
Servos are classified by CH, but
sensors
are classified in units called
"slot"
. There are
slots
from
No. 1
to
No. 31
.
Altitude sensors, GPS sensors
and other data sensor units may use
multiple slots
.
Using a sensor which uses two or more slots, the required number of slots is automatically
assigned by setting up a
start slot
.
When 2 or more of the same kind of sensor are used, the sensors themselves must allocate
unused slots and memorize that slot.
Sensor
The required
number of slots
The number which can be used as a start slot
Selling area
TEMP(SBS-01T)
1 slot
1 〜 31
Global
RPM(SBS01RM,SBS-
01RO)
1 slot
1 〜 31
Voltage(SBS-01V)
2 slot
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0
, 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
Altitude(SBS-01A)
3 slot
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 , 2 4
, 2 5 , 2 6 , 2 7 , 2 8 , 2 9
GPS(SBS-01G)
8 slot
8 , 1 6 , 2 4
TEMP125-F1713
1 slot
1 〜 31
Europe
VARIO-F1712
2 slot
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0
, 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
VARIO-F1672
2 slot
1 , 2 , 3 , 4 , 5 , 6 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 4 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0
, 2 1 , 2 2 , 2 4 , 2 5 , 2 6 , 2 7 , 2 8 , 2 9 , 3 0
CURR-F1678
3 slot
1 , 2 , 3 , 4 , 5 , 8 , 9 , 1 0 , 1 1 , 1 2 , 1 3 , 1 6 , 1 7 , 1 8 , 1 9 , 2 0 , 2 1 , 2 4
, 2 5 , 2 6 , 2 7 , 2 8 , 2 9
GPS-F1675
8 slot
8 , 1 6 , 2 4
<
Assignable slot
>
*Altimeter, GPS, and other sensors that display a large amount of data require multiple slots.
*Depending on the type of sensor, the slot numbers that can be allocated may be limited.
● The
"SENSOR"
of a menu is chosen, and
Jog key
press.
● Slot number
● 3 slots SBS-01A is
used.
● 8 slots SBS-01G is used.
● SensorID:When multiple sensors of the same type are
not used, ID is unnecessary.
●
Jog key
presses side and makes it 2 pages.
SENSOR SLOT
1
2 3 4 5 6
1▶ SBS-01T *****
3▶ SBS-01A *****
4 SBS-01A
5 SBS-01A
6▶ SBS-01V *****
2▶ SBS-01RM/O *****
SENSOR SLOT 1
2
3 4 5 6
7 SBS-01V
9 SBS-01G
10 SBS-01G
11 SBS-01G
12 SBS-01G
8▶ SBS-01G *****