PROBLEM: The AC load will not operate, error code shows on
digital display and alarm is sounding.
Error
Possible cause
Remedy
Low voltage shutdown because
battery is discharged.
Over-voltage shutdown because
of high input voltage.
The AC product(s) connected
are rated at more than the
inverterʼs continuous power
rating; overload shutdown has
occurred.
The inverter has overheated due
to poor ventilation.
Overheating shutdown has
occurred.
The AC products connected
have a surge power that exceeds
the inverterʼs surge capability or
the AC products connected are
short-circuited and shutdown
has occurred.
Recharge battery.
Shorten cables or use heavier cables.
Verify the charging system is properly
regulated and the battery is 12 V
nominal.
Use a product with a power rating
within the inverterʼs continuous power
rating (see Table 3).
Turn inverter off and allow to cool
for 15 minutes. Clear blocked fan or
remove objects covering unit. Move the
inverter to a cooler place. Reduce load if
continuous operation is required.
The products exceed the inverterʼs surge
capability. Use a product with a starting
surge power within the inverterʼs
capability.
Correct the short-circuit condition.
Error
Possible cause
Remedy
Error
Possible cause
Remedy