17
5. Operating the Inverter
This section explains how to operate the inverter most effi ciently.
Operating conditions and guidelines
This section describes normal operation as well as conditions that
trigger an alarm or automatically shut down the inverter.
Normal Operation
When you connect the inverter to the vehicleʼs
DC accessory socket or directly to a 12 V battery and turn on the
unit, the digital display will show input voltage, the input voltage LED
illuminates and AC power is available at the outlets. You can now plug
in your AC products and turn them on one at a time.
Low Battery Alarm and Shutdown
As the battery discharges, its
voltage decreases. When the inverter senses that the voltage at its DC
input has dropped to 11.0 V, it sounds an alarm, giving you time to
shut down sensitive loads such as computers. If you ignore the alarm,
and the DC input voltage drops below 10.5 V, the inverter shuts down
all loads to save the battery from further discharge. The under-voltage
error code ʻ
E01
ʼ will show on the digital display.
High-input Voltage Shutdown
If a defective battery charging system
causes the battery voltage to rise to dangerously high levels, the
inverter shuts down automatically. The over-voltage error code ʻ
E02
ʼ
will show on the digital display.