2. WIRING
2-12
2.2.4
Ethernet HUB and USB Device Server
The optional USB device server UDS-001 enables the extension of the trackball con-
trol unit cable. The optional HUB-101 Ethernet HUB is required to connect the UDS-
001. The Ethernet HUB also allows connection to external network fish finders. Refer
to the interconnection diagram at the end of this manual to connect the units.
When connecting the trackball control unit TCU-001, the UDS-001 DIP switches must
be returned to the default settings, as follows:
SW No.
Settings (default)
SW1
SW2
SW3
Using special crimping tool
MPT5-8AS (PANDUIT CORP.),
crimp the modular plug.
Finally check the plug visually.
Expose inner vinyl sheath.
Remove the outer sheath by
approx 25 mm. Be careful
not to damage inner shield
and cores.
Fold back the shield, wrap it
onto the outer sheath and
cut it, leaving 9 mm.
1
2
3
25 mm
approx. 9 mm
4
5
6
approx. 9 mm
approx. 11 mm
Drain wire
Fold back drain wire and
cut it, leaving 9 mm.
Straighten and flatten the
core in order and cut them,
leaving 11 mm.
Insert the cable into the modular
plug so that the folded part of
the shield enters into the plug
housing. The drain wire should
be located on the tab side of
the jack.
7
1
8
Modular plug
1 WHT/GRN
2 GRN
3 WHT/ORG
4 BLU
5 WHT/BLU
6 ORG
7 WHT/BRN
8 BRN
WHT/ORG 1
ORG 2
WHT/GRN 3
BLU 4
WHT/BLU 5
GRN 6
WHT/BRN 7
BRN 8
[Cross cable]
OFF
ON
OFF
OFF
Содержание FCV-2100
Страница 6: ...EQUIPMENT LISTS iv This page is intentionally left blank...
Страница 14: ...1 MOUNTING 1 8 This page is intentionally left blank...
Страница 46: ...3 INITIAL SETTINGS 3 18 This page is intentionally left blank...
Страница 52: ...16 Nov 2015 H MAKI 16 Nov 2015 H MAKI...
Страница 53: ...17 Nov 2015 H MAKI 17 Nov 2015 H MAKI...
Страница 54: ...26 Feb 2016 H MAKI 26 Feb 2016 H MAKI...
Страница 55: ...17 Nov 2011 Y NISHIYAMA 17 Nov 2011 Y NISHIYAMA...
Страница 56: ...17 Nov 2011 Y NISHIYAMA 17 Nov 2011 Y NISHIYAMA...
Страница 57: ...17 Nov 2011 Y NISHIYAMA 17 Nov 2011 Y NISHIYAMA...
Страница 58: ...8 Mar 2016 H MAKI...