1. OPERATIONAL OVERVIEW
6
1.5
How to Set the Sonar
The range, gain and user program number are displayed on the top right of the screen.
To change the value, put the cursor on the [R], [G] or [P] area then spin the scrollwheel.
• [R]: Shows the display range (setting range: 100 m to 5,000 m). When the FSV-25 operates in
the H(orizontal)/V(ertical) alternate mode, the setting value is limited to the range of the FSV-
25 in the V(ertical) mode or less.
Note:
When the FSV-25 is in the H mode or the H2 (horizontal combination) mode, the TX
(transmission) interval of the FSV-25 is reduced depending on the range setting of the F3D-S.
The TX interval does not decrease when V mode is in use.
• [G]: Shows the receiver gain (setting range: 0.0 to 10.0).
• [P]: Shows the user program number (setting range: 1 to 10). When the cursor is in the [P] area,
the comment* for the selected user program number is displayed on the left.
*: You can set the comment about the menu settings for views including the view arrangement.
For details, see section 2.8.
1.6
How to Set the Vslice Bearing Mark
To set the Vslice bearing mark on 3D-View or Top-View, click the Vslice number and then spin the
scrollwheel, or drag the Vslice number. You can set the Vslice bearing mark while the Vslice num-
ber is displayed in cyan color.
R 700m
G 2.2
P 3
Range
Gain
User program number
Vslice number
Vslice bearing mark
3D-View
Top-View
Vslice bearing mark
Vslice number
Vslice bearing plane (Translucent white fan)