background image

2.  UPPER USER MENU

17

2.8

User Program

You can save up to 10 shortcut programs for views including the view arrangement.

1. Click 

 to show the upper user menu.

2. Click 

 to open the user program menu.

3. Click .
4. Click a user program number icon. The caution message "Are you sure to change registered 

settings?" appears.

5. Click [Yes]. The following dialog box appears.

6. Enter the comment for the user program (max. 64 characters) and then click [OK].

7. Click 

 to hide the upper user menu.

How to select a user program

Open the user program menu and then click the user program number icon among the registered 
numbers. The selected program number is displayed at the top right of the screen (see 
section 1.2.5).

Save icon

Return icon: Returns to 
the upper user menu.

User program number icons

(Unregistered number icons are displayed in gray.)

Close the menu.

Содержание 3D Sonar Visualizer F3D-S

Страница 1: ...3D Sonar Visualizer F3D S OPERATOR S MANUAL www furuno com Model Option for FSV 25 FSV 25S ...

Страница 2: ......

Страница 3: ... the Depth Range Line 7 1 8 How to Measure the Range by Range Cursor 7 2 UPPER USER MENU 8 2 1 How to Reset the Viewpoint 8 2 2 How to Scale or Move the View 9 2 3 How to Enter the Echo Region Mark 9 2 4 How to Enter the Event Mark 10 2 5 How to Enter the Purse Net Mark 11 2 6 How to Enter the Trawl Mark 12 2 7 Seabed Color 15 2 8 User Program 17 3 LOWER USER MENU 18 3 1 How to Save the View Setti...

Страница 4: ... Hereafter FSV 25 refers to FSV 25 or FSV 25S The main features of the F3D S are as shown below Fish schools of surface to middle layer can be observed at the same time Movement of fish schools can be viewed instantly 3D visualization of ship s surroundings Storage and replay of picture and settings Four views 3D View Top View Side View and Vslice View can be displayed on the screen Relative posit...

Страница 5: ...IF Unit FSV 8502 Control Unit FSV 2501 Hull Unit FSV 253 254 Transceiver Unit FSV 251 Junction Box FSV 2550 Raise Lower Control Box FSV 2530 Monitor Power Supply Unit FSV 252 100 110 115 220 230 VAC 1ø 50 60 Hz Rectifier RU 1746B 2 100 110 115 220 230 VAC 1ø 50 60 Hz 12 24 VDC Standard supply Local or optional supply 200 220 VAC 3ø 50 60 Hz ...

Страница 6: ...r the start up is completed the following screen appears Note If the following message appears click OK to deleted the message and then re insert the USB dongle 5 To quit the software click the close button x at the upper right hand corner of the screen All setting information is saved to the folder C Users User name Documents FURUNO F3D S Note If the information has not been saved open the proper...

Страница 7: ...m foreside of the screen See section 3 5 3 Top View echo Shows a bird s eye view of the echoes around the ship 4 3D View echo Shows a diagonal 3D view of the echoes 5 Vslice View echo Shows vertical slices of echoes at the same orientation as the vertical settings on the FSV 25 6 Settings of sonar Shows the range gain and user program number 7 External input data Shows the data output from externa...

Страница 8: ...iew of the echoes around the ship The Top View mode is useful for measuring the horizontal distance and direction to the fish school Vslice number Vslice bearing mark Bearing scale Vslice bearing plane Translucent white fan Range ring Translucent green dotted line Depth line Translucent yellow dotted line Heading line Own ship mark Track Translucent green line North mark Translucent white short li...

Страница 9: ...uring the depth of the fish school 1 2 4 Vslice View mode The Vslice View mode shows vertical slices of echoes at the same orientation as the vertical set tings on the FSV 25 You can display two directional Vslice views The Vslice View mode is useful for detecting the fish school distribution in a specific direction Also this mode is useful for com paring the depth of two targets in the different ...

Страница 10: ...lick or on the upper or lower InstantAcces bar 1 4 How to Change the Viewpoint You can change the viewpoint when no menu icons are selected To change the viewing angle drag the 3D View echo up or down To change the view point origin drag the 3D View Top View or Side View echo to the right or left This function is available on the Top View and Side View when checking the box for Rotate Top View Sid...

Страница 11: ...terval does not decrease when V mode is in use G Shows the receiver gain setting range 0 0 to 10 0 P Shows the user program number setting range 1 to 10 When the cursor is in the P area the comment for the selected user program number is displayed on the left You can set the comment about the menu settings for views including the view arrangement For details see section 2 8 1 6 How to Set the Vsli...

Страница 12: ...surement Click the scrollwheel on an area other than the menu icons and move the cursor on a view Spin the scrollwheel to measure the range To cancel measuring do one of the followings Click the scrollwheel on an area other than the menu icons When the Vslice number is displayed in cyan click the Vslice number When the depth range line is displayed in cyan click the depth range line When the seabe...

Страница 13: ...he menu bar on a view click the area out of a view 2 1 How to Reset the Viewpoint Click to reset the viewpoint The depression and azimuth of the viewpoint are reset to the setting for the currently selected user program Icon Name Description Section Show Shows the upper user menu 1 3 Hide Hides the upper user menu 1 3 Reset Viewpoint Resets viewpoint orientation This mark is always dis played 2 1 ...

Страница 14: ...layed in 3D View Top View or Side View The echo area including the point clicked is displayed in yellow or cyan lines The volume for echo region mark is displayed at the right of the screen Note 1 You cannot mark an area designated as echo region 2 with echo region mark 1 and vice versa Note 2 When updating the echo display while echo region marks are displayed if there are strong echo after updat...

Страница 15: ...Note 1 Up to 10 event marks can be entered When entering the 11th event mark the oldest event mark is deleted and the 11th input event mark is displayed as the latest event mark Note 2 When updating the echo display the event mark out of the view is not displayed 5 Click to deactivate the function 6 Click to hide the upper user menu How to delete the event mark To delete the event mark do one of t...

Страница 16: ... view are not displayed 4 Click to deactivate the function 5 Click to hide the upper user menu How to move the purse net mark To move the purse net mark do one of the following When is selected put the cursor on the purse net mark and drag the purse net mark to the desired position When is not selected right click the purse net mark then click Move The icon chang es to the selected status Drag the...

Страница 17: ... trawl door are displayed in numerical values Click and then move the cursor to the view area 1 2 Click the position to place the trawl door marks 3 Click another position to move one of two trawl door marks 4 Move the cursor to the area other than the trawl door marks Trawl door marks Trawl mouth mark Warps Reins Distance from own ship to the center of trawl door mark To reset the trawl mark righ...

Страница 18: ...line or a trawl mark this line is displayed in cyan color On other occasions this line is displayed in white 3 To set the trawl mark depth on Side View or Vslice View do one of the following 4 Click to deactivate the function All numerical indications related to the trawl mark are removed 5 Click to hide the upper user menu On Side View Put the cursor on a trawl door mark and drag the trawl door m...

Страница 19: ...sh school and seabed are suppressed Note The trawl filter can selectively detect the trawl doors in the specified direction However in some cases where the trawl doors are at the edge of the detection area the trawl doors may not appear on screen If this happens disable the trawl filter To activate the trawl filter do the following 1 Click to show the upper user menu 2 Click 3 Click to activate th...

Страница 20: ...ne on Vslice View 3 Move the cursor on the seabed border line The line color changes from translucent yellow to cyan 4 To set the depth for the seabed border line drag seabed depth mark 1 up and down To set the tilt for the seabed border line drag seabed depth mark 2 up and down To deactivate seabed color function click Seabed Color OFF Seabed Color ON Seabed border line Seabed depth mark 2 Seabed...

Страница 21: ...e sea bed border line with offset value 0 m is displayed 2 Spin the scrollwheel to offset the seabed depth 3 Click the area out of Vslice View to hide the white dotted line How to set the auto depth on The auto depth function uses the detected water depth to calculate where to display the seabed border line To activate this function click and then click Seabed border line Seabed depth mark 2 Seabe...

Страница 22: ...ck Yes The following dialog box appears 6 Enter the comment for the user program max 64 characters and then click OK 7 Click to hide the upper user menu How to select a user program Open the user program menu and then click the user program number icon among the registered numbers The selected program number is displayed at the top right of the screen see section 1 2 5 Save icon Return icon Return...

Страница 23: ...r Vslice View 1 Click to show the lower user menu 2 Click to open the view setting menu Icon Name Description Section Show Shows the lower user menu 1 3 Hide Hides the lower user menu 1 3 View Setting Opens the view setting menu 3 1 Connect Connects the PC to the FSV 25 25S 3 2 Disconnect Disconnects the PC from the FSV 25 25S 3 2 Replay Opens replay menu 3 4 Start Recording Records echo data 3 3 ...

Страница 24: ...ick to reset the view setting to the default 3 2 How to Connect Disconnect the PC to the FSV 25 1 Click to show the lower user menu 2 Click to start communication with the FSV 25 25S The color of the connect icon chang es to gray Note 1 When the FSV 25 25S is not turned on the gray indication of the connect icon is can celed 20 seconds after clicking Note 2 This function is not available while rep...

Страница 25: ...images click To set the save destination folder see section 3 5 Note When the capacity of the folder is full recording of the echo data is stopped and the caution message Recording has stopped due to insufficient space appears 3 To stop recording click 4 Click to hide the lower user menu 3 4 How to Replay the Echo Data You can replay the recorded echo data 1 Click to show the lower user menu 2 Cli...

Страница 26: ...mp dialog box Select the file number and click Jump to replay the selected file Opens the interval setting dialog box Select the re playing interval between each file on the millisecond time scale and click OK Returns to the upper user menu Closes the menu Icon Description Click or to select the file number Click or to select the interval ...

Страница 27: ...wl mouth mark setting range 10 to 400 m 10 m steps Trawl Mouth Slope Set the tilt of the trawl mouth mark setting range 0 to 45 degrees 1 degree steps Purse Net Radius Set the radius of the net mark setting range 10 to 1000 m 10 m steps Purse Net Height Set the height of the net mark setting range 10 to 1000 m 10 m steps Destination to Save Make Date Folder Check the box to make a folder named wit...

Страница 28: ...f the IP address is correctly set For details see section 1 4 of the installation manual Pictures are slowly up dated Operation re sponse is slow The PC does not meet the minimum require ments for the software Check the PC requirements For details see section 1 1 of the installation manual Pictures are not updated or freeze The FSV 25 is doing a test Pictures are not updated during a test in the F...

Страница 29: ...has been disconnected Communication between the F3D S software and the FSV 25 is disconnected Confirm if the LAN cable is firmly connected and then click on the lower In stantAccess bar to con nect the PC to the FSV 25 800407D1 Failed Read File The selected file can not be read Select another file 800407D3 File Format Error The file format is not cor rect Select another file 8004100D Data acquisit...

Страница 30: ......

Страница 31: ......

Страница 32: ...FSV 25 Pub No OMC 13442 A Printed in Japan 機器の修理 使用方法等に関するお問い合わせは お買い上げの販売店 代理店 最寄りの 当社支店 営業所あてへお願いします Elemental Chlorine Free The paper used in this manual is elemental chlorine free FURUNO Authorized Distributor Dealer お問い合わせは JUL 2019 A 00019680510 ...

Отзывы: