BEFORE INSTALLATION

This water heater is certified for installation in 
Recreational Vehicles (RV’s) and is not for use in Marine 
or Space Heating Applications.
The installation must conform to one or more of the 
following, as applicable:

1.  Local codes or, in the absence of local codes, the National 

Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or CSA B149.1, 
Natural Gas and Propane Installation Code.

2.  Local codes or, in the absence of local codes, Recreational 

Vehicles, NFPA 1192 and/or CAN/CSA-Z240 RV Series.

USA AND CANADA - FOLLOW ALL APPLICABLE STATE 
AND LOCAL CODES 
IN THE ABSENCE OF LOCAL CODES OR REGULATIONS 
REFER TO CURRENT STANDARDS.

  WARNING - CAUTION

 

Improper installation, adjustment, alteration, service or 
maintenance can cause property damage, personal 
injury or loss of life.

 

Installation and Service must be performed by a Furrion 
recommended installer, service agency or gas supplier.

The following instructions apply to the most common type 
of installation for Furrion F2GWH Water Heater. Consult 
with Furrion Technical Support or Engineering department 
if you have any additional questions regarding your specific 
installation/application.

IMPORTANT!

For proper operation this water heater requires a minimum 
water flow of .80 Gallon per Minute (gpm) for each Hot 
Water faucet it supplies.

Select a Suitable Location

The water heater is designed to be installed on a floor or a 
fixed platform with access to water, LP gas and a 12VDC 
electrical connection from the back. It is recommended that 
the F2GWH be located as near the center of the coach as 
possible.

 

DO NOT INSTALL IN AN AREA WHERE ONE OR 
BOTH THE INLET AIR VENT AND FLUE VENT CAN 
BE COVERED BY A DOOR OR ACCESS PANEL WHEN 
OPENED.

 

DO NOT INSTALL WHERE THE FLUE VENT IS CLOSER 
THAN ONE FOOT IN ALL DIRECTIONS FROM ANY 
WINDOW OR OPENING INTO THE VEHICLE.

 

DO NOT INSTALL THE WATER HEATER OR ANY OTHER 
APPLIANCE WHERE IT CAN VENT INTO AN AREA 

COVERED BY AN AWNING, CANOPY OR ANY OTHER 
ENCLOSURE.

NOTE: 

The water heater can be installed under an RV roll-out/

retractable type awning providing the awning does not have an 
enclosure such as a screen room and/or some type of “walled 
enclosure”.

Site Preparation

To install on carpeted area you must install a metal or wood 
panel under the water heater that extends at least 3 inches 
beyond the width and depth of the unit. If water leakage can 
result in damage to the adjacent area, install a drain pan that 
can be drained to outside of the vehicle, under the water 
heater.
Verify that a clearance of 1 inch will remain after installation 
between the top surface of the water heater and any 
combustible material. Zero inch clearance is acceptable for the 
sides.
Make sure that the front edge of the opening is surrounded by 
a solid frame to firmly anchor the water heater; if needed, build 
an appropriate frame using 2" X 2" elements.

The rough opening for the F2GWH should be 13" X 13" with 
right angle corners. The exterior wall opening must be the 
same dimensions with no radius corners.
Ensure that electrical water and gas connections from the 
vehicle are in place for installing the unit.
Allow sufficient length and flexibility in the electrical, water and 
gas lines to reach the connections while the unit is partially 
inserted into the opening.

Содержание F2GWH

Страница 1: ...NCES EXCEPTASNOTED 0TO6mm 0 1 6TO30mm 0 2 30TO80mm 0 3 80TO180mm 0 4 180mm 0 5 ANGULAR 3 FINISHSPEC COMPOSITE NO SHEET1OF1 SCALE DATE DRAWNBY APPROVEDBY REVISION NAME PARTNO Program Indesign CC Black...

Страница 2: ...Tankless Water Heater Chauffe eau Gaz Sans R servoir MODEL MOD LE F2GWH USER MANUAL MANUEL D UTILISATION Picture shown here is for reference only L image montr e ici est uniquement pour r f rence...

Страница 3: ...fueling Keep these instructions and warranty for future reference Follow all applicable State and Local Codes Follow a regular schedule of maintenance as outlined in this manual TABLE OF CONTENTS EXPL...

Страница 4: ...off the gas supply at the gas container or source Contact the nearest certified service technician or gas supplier for repairs If you cannot reach a certified service technician or gas supplier contac...

Страница 5: ...be located as near the center of the coach as possible DO NOT INSTALL IN AN AREA WHERE ONE OR BOTH THE INLET AIR VENT AND FLUE VENT CAN BE COVERED BY A DOOR OR ACCESS PANEL WHEN OPENED DO NOT INSTALL...

Страница 6: ...and the vehicle s frame 4 Insert the door flange into the water heater housing and press the flange firmly against the sidewall 5 When ready to proceed apply additional caulking or butyl tape to the b...

Страница 7: ...erior Water Heater Power Switch if installed 2 Turn on the water supply to the unit 3 Open and then close the HOT COLD water faucets in the vehicle to fill the pipes with water If needed purge air out...

Страница 8: ...teady water flow no pulsating will ensure a consistent temperature and performance 2 The RV s hot water system i e faucets and shower 3 The RV s LP Gas system capable of supplying its rated BTU requir...

Страница 9: ...ol Valve Flow Optimization optional The Water Control Valve of the F2GWH provides good control of the outlet temperature within a wide range of inlet water temperatures as are normally encountered in...

Страница 10: ...o occur in the F2GWH it will be detected by the Controller Module and the specific cause will be indicated by the Error Code on the User Control Panel display E0 Water Outlet Temperature Probe failure...

Страница 11: ...fect the performance of the unit Inspect the Flue Outlet Tube to make sure that It is unobstructed and that the screen is clean If debris or insects are present clean and vacuum to remove any remainin...

Страница 12: ...t 2 1 28 Temperature Probe for Water Inlet 1 29 Inlet Thermostat Antifreeze 1 30 Temperature Probe for Water Outlet 1 Description Photo Qty 31 Heater Exchanger 1 32 ECO T Switch 1 33 Strain Relief 1 3...

Страница 13: ...contact Furrion 3 Call the service center describe your problem and make an appointment if necessary SERVICE CALLS TO CUSTOMER LOCATION ARE THE RESPONSIBILITY OF THE OWNER 4 FURRION WILL NOT PAY THE...

Страница 14: ...lack Inlet temp probe Outlet temp probe Remote controller Water flow sensor Wind pressure switch Flame sensor Red Ignition pin GND To Switch On Off proportional valve To Proportional valve To ECO ther...

Страница 15: ...English CCD 0005833 Rev 04 14 22 13 Control Module and its Connections...

Страница 16: ...ervez ces instructions et la garantie pour r f rence future Suivez tous les codes d tat et locales applicables Suivez un programme r gulier d entretien comme indiqu dans ce manuel TABLE DES MATI RES E...

Страница 17: ...limentation en gaz la bouteille de gaz ou la source Contactez un technicien de service certifi le plus proche ou le fournisseur de gaz pour les r parations Si vous ne pouvez pas parvenir un technicien...

Страница 18: ...S UN ENDROIT O LA PRISE D AIR OU L VENT D VACUATION PEUVENT TRE RECOUVERTS LORSQU UNE PORTE OU UN PANNEAU D ACC S DU V HICULE EST OUVERT NE PAS INSTALLER DANS UN ENDROIT O L VENT D VACUATION SE TROUVE...

Страница 19: ...u chauffe eau Utilisation d un mat riau de calfeutrage appropri qui se traduira par un joint permanent entre le chauffe eau et le ch ssis du v hicule 4 Ins rez la bride de la porte dans le bo tier de...

Страница 20: ...ilisant un interrupteur int rieur non fourni ou en d sactivant le circuit du Chauffe Eau AVERTISSEMENT NE PAS utiliser d allumettes de bougies ou toute autre source d allumage pour v rifier lapr sence...

Страница 21: ...ENT AVERTISSEMENT CONSIGNES DE S CURIT DESTIN ES AU CONSOMMATEUR Utiliser uniquement avec du gaz de propane liquide Lors du r approvisionnement en carburant teindre les appareils gaz et les flammes pi...

Страница 22: ...re install e au niveau du raccord de sortie de l eau chaude du chauffe eau lors de l installation Les codes locaux doivent r gir l installation de toute soupape de d charge La soupape de d charge n es...

Страница 23: ...aison il est recommand de suivre la les recommandation s ci dessous si l unit doit tre entrepos e dans un environnement hivernal ou pour de longues p riodes de temps Au d but de la saison d hiver ou a...

Страница 24: ...ct avant l allumage ou pendant le fonctionnement normal Cela pourrait tre aussi caus par un d faut de c blage dans les connexions du moteur E6 Surtemp rature Temp rature de sortie d eau a d pass 140 F...

Страница 25: ...leentre la Carte de Contr le et l allumeur est bien en place et n est pas court circuit l un des composants m talliques 8 Au moins une fois par an activer la soupape de s curit pour v rifier que ther...

Страница 26: ...1 F2GWHDAS10 Bride Seulement 1 12 Charni re de porte 1 13a Anneau de Purge en silicone BLANC 1 13b Anneau de Purge en silicone NOIR 1 14a Verrou de porte BLANC 1 14b Verrou de porte NOIR 1 15 Ressort...

Страница 27: ...chauffage d eau comme indiqu sur la plaque signal tique attach e CARACT RISTIQUES Caract ristiques BTU HR 42 000 BTU carburant Propane LP Gas Inlet Pressure 11 WCI Min to 14 WCI Max Pression d admiss...

Страница 28: ...Coupure d urgence Capteur de niveau de cong lation Un diagramme des c blages des connexions lectriques l int rieur de l unit Cutting 1 Blue 2 Blue White White Blue Blue White Red Black Brown 5 Yellow...

Страница 29: ...az vanne d entr e 15 Br leur 16 Coquille Inf rieure 17 Tube de direction de la vanne de d compression 18 Soupape de d charge de pression 19 Conduite d eau Assy 20 Joint en caoutchouc 1 21 Assemblage d...

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ...ion logo are trademarks licensed for use by Furrion Ltd and registered in the U S and other countries 2007 2022 Furrion Ltd Furrion et le logo Furrion sont des marques commerciales utilis es sous lice...

Отзывы: