background image

English

 

CCD-0005833 Rev: 04-14-22

- 6 -

If necessary for service, the door can be removed by removing 
hinge screws. Keep screws in a secure pace for remounting 
the door. Optional - To further secure the door, you may add a 
screw in the hole provided in the bottom.
To further secure the door, add a screw in the hole provided in 

the bottom.
If necessary for service, the door can be removed by extracting 
the pins that retain the hinges. Take care not to lose the pins to 
replace the door when finished.

  WARNING - CAUTION

 

The appliance and its individual shut-off valve must be 
disconnected from the gas supply piping system during 
any pressure testing of that system at test pressures in 
excess of ½ psi.

 

The appliance and its gas connection must be leak 
tested before placing the appliance in operation.

 

If an external electrical source is utilized, the appliance, 
when installed, must be electrically grounded in 
accordance with local codes or, in the absence of local 
codes, with the National Electrical Code, ANSI/NFPA 70 
and/or the CSA C22.1, Canadian Electrical Code.

This completes the installation instructions of the Model 
F2GWH water heater.

OPERATION

  WARNING

CONSUMER SAFETY WARNING!

 

Use with LP gas only.

 

Shut off all gas appliances and pilot lights when refueling.

 

Turn gas OFF at the LP tank when vehicle is in motion. 
This disables all gas appliances and pilot lights. Gas 
appliances must never be operated while vehicle is in 
motion.

 

LP tanks must be filled by a qualified gas supplier only.

 

Should overheating occur, turn gas OFF at the LP tank 
and turn the operating switch to the OFF position.

A: Understanding How the Furrion 
Tankless Water System Works

In a conventional installation the Furrion Tankless Water Heater 
is connected to:
1.  The RV’s cold water system deriving its water input from 

a pressurized (45 psi or greater) source such as a shore 
connection or an RV water pump connected to the RV’s 
fresh water storage tank.  

NOTE

 - A steady water flow (no pulsating) will ensure a 

consistent temperature and performance.

2.  The RV’s hot water system (i.e. faucets and shower).
3.  The RV’s LP Gas system capable of supplying its rated 

BTU requirement. The Furrion model F2GWH introduces a 
new generation of smart tankless water heater designed 
specifically for Recreation Vehicles (RV). Its configuration 
and size are consistent with the tank based RV water 
heaters currently in use and is designed for OEM’s and 
after- market use by the RV industry.

4.  The RV’s 12VDC electrical power.
The Water Heater’s microprocessor based controller (Control 

Module) receives from electronic sensors the data it needs to 
decide each step of the Model F2GWH operation.
1.  Display on the User Control Panel (UCP) each phase of 

the Water Heater’s operation and receive from the user the 
operation parameters desired:

 

ON/OFF to activate

 

Desired outlet temperature

2.  Verify that all components are in working order and that it 

is safe to start the unit upon sensing the minimum amount 
of water flow required (.90 Ga/min)

3.  Verify that the blower is operating and supplies the air flow 

needed to maintain clean combustion.

4.  Open the gas control and light the burner according to the 

procedure required by the safety standard.

5.  Adjust the gas flow to reach and maintain the desire 

temperature set by the user

6.  Continue operation as long as:

 

The water flow is above the minimum required

 

The presence of flame is verified

 

No unsafe condition develops

7.  Provide the user with a visual indication of the operating 

conditions turning on the appropriate icon and displaying 
the current outlet temperature:

 

Fan icon on: Blower operating

 

Flame icon on: Burner is lit and flamed is detected

 

Shower Head on: Water is flowing

8.  The button marked “C/F” determines if the temperature is 

displayed in °F or °C degrees

9.  Whenever the “UP” or “Down” are pressed the display 

shows the set temperature.

10.  If an unsafe condition is encountered and the unit shuts off, 

the display will show an Error Code corresponding to the 
actual condition that caused the unsafe condition.

See Troubleshooting section for a list of all error codes.

Содержание F2GWH

Страница 1: ...NCES EXCEPTASNOTED 0TO6mm 0 1 6TO30mm 0 2 30TO80mm 0 3 80TO180mm 0 4 180mm 0 5 ANGULAR 3 FINISHSPEC COMPOSITE NO SHEET1OF1 SCALE DATE DRAWNBY APPROVEDBY REVISION NAME PARTNO Program Indesign CC Black...

Страница 2: ...Tankless Water Heater Chauffe eau Gaz Sans R servoir MODEL MOD LE F2GWH USER MANUAL MANUEL D UTILISATION Picture shown here is for reference only L image montr e ici est uniquement pour r f rence...

Страница 3: ...fueling Keep these instructions and warranty for future reference Follow all applicable State and Local Codes Follow a regular schedule of maintenance as outlined in this manual TABLE OF CONTENTS EXPL...

Страница 4: ...off the gas supply at the gas container or source Contact the nearest certified service technician or gas supplier for repairs If you cannot reach a certified service technician or gas supplier contac...

Страница 5: ...be located as near the center of the coach as possible DO NOT INSTALL IN AN AREA WHERE ONE OR BOTH THE INLET AIR VENT AND FLUE VENT CAN BE COVERED BY A DOOR OR ACCESS PANEL WHEN OPENED DO NOT INSTALL...

Страница 6: ...and the vehicle s frame 4 Insert the door flange into the water heater housing and press the flange firmly against the sidewall 5 When ready to proceed apply additional caulking or butyl tape to the b...

Страница 7: ...erior Water Heater Power Switch if installed 2 Turn on the water supply to the unit 3 Open and then close the HOT COLD water faucets in the vehicle to fill the pipes with water If needed purge air out...

Страница 8: ...teady water flow no pulsating will ensure a consistent temperature and performance 2 The RV s hot water system i e faucets and shower 3 The RV s LP Gas system capable of supplying its rated BTU requir...

Страница 9: ...ol Valve Flow Optimization optional The Water Control Valve of the F2GWH provides good control of the outlet temperature within a wide range of inlet water temperatures as are normally encountered in...

Страница 10: ...o occur in the F2GWH it will be detected by the Controller Module and the specific cause will be indicated by the Error Code on the User Control Panel display E0 Water Outlet Temperature Probe failure...

Страница 11: ...fect the performance of the unit Inspect the Flue Outlet Tube to make sure that It is unobstructed and that the screen is clean If debris or insects are present clean and vacuum to remove any remainin...

Страница 12: ...t 2 1 28 Temperature Probe for Water Inlet 1 29 Inlet Thermostat Antifreeze 1 30 Temperature Probe for Water Outlet 1 Description Photo Qty 31 Heater Exchanger 1 32 ECO T Switch 1 33 Strain Relief 1 3...

Страница 13: ...contact Furrion 3 Call the service center describe your problem and make an appointment if necessary SERVICE CALLS TO CUSTOMER LOCATION ARE THE RESPONSIBILITY OF THE OWNER 4 FURRION WILL NOT PAY THE...

Страница 14: ...lack Inlet temp probe Outlet temp probe Remote controller Water flow sensor Wind pressure switch Flame sensor Red Ignition pin GND To Switch On Off proportional valve To Proportional valve To ECO ther...

Страница 15: ...English CCD 0005833 Rev 04 14 22 13 Control Module and its Connections...

Страница 16: ...ervez ces instructions et la garantie pour r f rence future Suivez tous les codes d tat et locales applicables Suivez un programme r gulier d entretien comme indiqu dans ce manuel TABLE DES MATI RES E...

Страница 17: ...limentation en gaz la bouteille de gaz ou la source Contactez un technicien de service certifi le plus proche ou le fournisseur de gaz pour les r parations Si vous ne pouvez pas parvenir un technicien...

Страница 18: ...S UN ENDROIT O LA PRISE D AIR OU L VENT D VACUATION PEUVENT TRE RECOUVERTS LORSQU UNE PORTE OU UN PANNEAU D ACC S DU V HICULE EST OUVERT NE PAS INSTALLER DANS UN ENDROIT O L VENT D VACUATION SE TROUVE...

Страница 19: ...u chauffe eau Utilisation d un mat riau de calfeutrage appropri qui se traduira par un joint permanent entre le chauffe eau et le ch ssis du v hicule 4 Ins rez la bride de la porte dans le bo tier de...

Страница 20: ...ilisant un interrupteur int rieur non fourni ou en d sactivant le circuit du Chauffe Eau AVERTISSEMENT NE PAS utiliser d allumettes de bougies ou toute autre source d allumage pour v rifier lapr sence...

Страница 21: ...ENT AVERTISSEMENT CONSIGNES DE S CURIT DESTIN ES AU CONSOMMATEUR Utiliser uniquement avec du gaz de propane liquide Lors du r approvisionnement en carburant teindre les appareils gaz et les flammes pi...

Страница 22: ...re install e au niveau du raccord de sortie de l eau chaude du chauffe eau lors de l installation Les codes locaux doivent r gir l installation de toute soupape de d charge La soupape de d charge n es...

Страница 23: ...aison il est recommand de suivre la les recommandation s ci dessous si l unit doit tre entrepos e dans un environnement hivernal ou pour de longues p riodes de temps Au d but de la saison d hiver ou a...

Страница 24: ...ct avant l allumage ou pendant le fonctionnement normal Cela pourrait tre aussi caus par un d faut de c blage dans les connexions du moteur E6 Surtemp rature Temp rature de sortie d eau a d pass 140 F...

Страница 25: ...leentre la Carte de Contr le et l allumeur est bien en place et n est pas court circuit l un des composants m talliques 8 Au moins une fois par an activer la soupape de s curit pour v rifier que ther...

Страница 26: ...1 F2GWHDAS10 Bride Seulement 1 12 Charni re de porte 1 13a Anneau de Purge en silicone BLANC 1 13b Anneau de Purge en silicone NOIR 1 14a Verrou de porte BLANC 1 14b Verrou de porte NOIR 1 15 Ressort...

Страница 27: ...chauffage d eau comme indiqu sur la plaque signal tique attach e CARACT RISTIQUES Caract ristiques BTU HR 42 000 BTU carburant Propane LP Gas Inlet Pressure 11 WCI Min to 14 WCI Max Pression d admiss...

Страница 28: ...Coupure d urgence Capteur de niveau de cong lation Un diagramme des c blages des connexions lectriques l int rieur de l unit Cutting 1 Blue 2 Blue White White Blue Blue White Red Black Brown 5 Yellow...

Страница 29: ...az vanne d entr e 15 Br leur 16 Coquille Inf rieure 17 Tube de direction de la vanne de d compression 18 Soupape de d charge de pression 19 Conduite d eau Assy 20 Joint en caoutchouc 1 21 Assemblage d...

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ...ion logo are trademarks licensed for use by Furrion Ltd and registered in the U S and other countries 2007 2022 Furrion Ltd Furrion et le logo Furrion sont des marques commerciales utilis es sous lice...

Отзывы: