Description

Photo

Qty

23

Écran de Filtrage – Entrée

1

24

Cache-poussière pour entrée + sortie

1

25

Entrée de commutateur de flux – 
Bouton

1

26

Capteur de débit d’eau

1

27

Joint en caoutchouc 2

1

28

Thermostat d’entrée (antigel)

1

29

Sonde de température pour entrée 
d’eau

1

30

Sortie d’eaude la sende de temperaturé

1

31

Sonde de température pour sortie d’eau

1

32

(ECO) T-Commutateur

1

33

Décharge de Traction

1

34

Moteur du Ventilateur Assy

1

Replacement Parts: Door Kit

#

Description

Photo

Qty

1

F2GWHD Kit de porte - (Blanc) Nouvelle 
Installation / Sub. 6 gal.

1

2

F2GHWDB Kit de porte - (Noir) Nouvelle 
Installation / Sub. 6 gal.

1

3

F2GWDA6 Kit de porte - Blanc Atwood 
6 gal.

1

#

Description

Photo

Qty

4

F2GWHDAS10 Kit de porte - Blanc Sub / 
Atwood 10 gal.

1

5

F2GWD Porte Seulement – Blanc

1

6

F2GWHDB Porte Seulement – Noir 

1

7

F2GWHD Bride Seulement

1

8

F2GWHDA6 Porte Seulement – Blanc

1

9

F2GWHDA6 Bride Seulement

1

10

F2GWHDAS10 Porte Seulement – Blanc

1

11

F2GWHDAS10 Bride Seulement

1

12

Charnière de porte

1

13a

Anneau de Purge en silicone – BLANC

1

13b

Anneau de Purge en silicone – NOIR

1

14a

Verrou de porte – BLANC

1

14b

Verrou de porte – NOIR

1

15

Ressort de Verrou de porte

1

SERVICE

Votre Chauffe-Eau sans réservoir Furrion est fabriqué selon 
les normes les plus élevées et est conçu pour durer plusieurs 
années d’utilisation sans problème. Mais dans le cas où vous 
avez besoin de service, veuillez suivre les étapes décrites ci-
dessous. Rappelez-vous qu’en tant que propriétaire, vous êtes 
tenu de fournir la preuve de la date d’achat par le biais d’un 
Acte de Vente ou autre document approprié.
1.  Pour plus d’informations de garantie / service, contactez 

un centre de service Chauffe-Eau Furrion; appelez le 

service d’assistance technique Furrion au 1-800-789-3341 
ou visitez notre site Web à www.furrion.com pour un centre 
de service locale recommandé.

2.  Si le chauffe-eau Furrion a été installé par le fabricant, il 

peut être sous leur garantie; suivez les étapes suggérées 
par le fabricant de votre VR ou contactez Furrion.

3.  Appelez le centre de service, décrivez votre problème et 

prenez un rendez-vous si nécessaire. LES APPELS DE 

Содержание F2GWH

Страница 1: ...NCES EXCEPTASNOTED 0TO6mm 0 1 6TO30mm 0 2 30TO80mm 0 3 80TO180mm 0 4 180mm 0 5 ANGULAR 3 FINISHSPEC COMPOSITE NO SHEET1OF1 SCALE DATE DRAWNBY APPROVEDBY REVISION NAME PARTNO Program Indesign CC Black...

Страница 2: ...Tankless Water Heater Chauffe eau Gaz Sans R servoir MODEL MOD LE F2GWH USER MANUAL MANUEL D UTILISATION Picture shown here is for reference only L image montr e ici est uniquement pour r f rence...

Страница 3: ...fueling Keep these instructions and warranty for future reference Follow all applicable State and Local Codes Follow a regular schedule of maintenance as outlined in this manual TABLE OF CONTENTS EXPL...

Страница 4: ...off the gas supply at the gas container or source Contact the nearest certified service technician or gas supplier for repairs If you cannot reach a certified service technician or gas supplier contac...

Страница 5: ...be located as near the center of the coach as possible DO NOT INSTALL IN AN AREA WHERE ONE OR BOTH THE INLET AIR VENT AND FLUE VENT CAN BE COVERED BY A DOOR OR ACCESS PANEL WHEN OPENED DO NOT INSTALL...

Страница 6: ...and the vehicle s frame 4 Insert the door flange into the water heater housing and press the flange firmly against the sidewall 5 When ready to proceed apply additional caulking or butyl tape to the b...

Страница 7: ...erior Water Heater Power Switch if installed 2 Turn on the water supply to the unit 3 Open and then close the HOT COLD water faucets in the vehicle to fill the pipes with water If needed purge air out...

Страница 8: ...teady water flow no pulsating will ensure a consistent temperature and performance 2 The RV s hot water system i e faucets and shower 3 The RV s LP Gas system capable of supplying its rated BTU requir...

Страница 9: ...ol Valve Flow Optimization optional The Water Control Valve of the F2GWH provides good control of the outlet temperature within a wide range of inlet water temperatures as are normally encountered in...

Страница 10: ...o occur in the F2GWH it will be detected by the Controller Module and the specific cause will be indicated by the Error Code on the User Control Panel display E0 Water Outlet Temperature Probe failure...

Страница 11: ...fect the performance of the unit Inspect the Flue Outlet Tube to make sure that It is unobstructed and that the screen is clean If debris or insects are present clean and vacuum to remove any remainin...

Страница 12: ...t 2 1 28 Temperature Probe for Water Inlet 1 29 Inlet Thermostat Antifreeze 1 30 Temperature Probe for Water Outlet 1 Description Photo Qty 31 Heater Exchanger 1 32 ECO T Switch 1 33 Strain Relief 1 3...

Страница 13: ...contact Furrion 3 Call the service center describe your problem and make an appointment if necessary SERVICE CALLS TO CUSTOMER LOCATION ARE THE RESPONSIBILITY OF THE OWNER 4 FURRION WILL NOT PAY THE...

Страница 14: ...lack Inlet temp probe Outlet temp probe Remote controller Water flow sensor Wind pressure switch Flame sensor Red Ignition pin GND To Switch On Off proportional valve To Proportional valve To ECO ther...

Страница 15: ...English CCD 0005833 Rev 04 14 22 13 Control Module and its Connections...

Страница 16: ...ervez ces instructions et la garantie pour r f rence future Suivez tous les codes d tat et locales applicables Suivez un programme r gulier d entretien comme indiqu dans ce manuel TABLE DES MATI RES E...

Страница 17: ...limentation en gaz la bouteille de gaz ou la source Contactez un technicien de service certifi le plus proche ou le fournisseur de gaz pour les r parations Si vous ne pouvez pas parvenir un technicien...

Страница 18: ...S UN ENDROIT O LA PRISE D AIR OU L VENT D VACUATION PEUVENT TRE RECOUVERTS LORSQU UNE PORTE OU UN PANNEAU D ACC S DU V HICULE EST OUVERT NE PAS INSTALLER DANS UN ENDROIT O L VENT D VACUATION SE TROUVE...

Страница 19: ...u chauffe eau Utilisation d un mat riau de calfeutrage appropri qui se traduira par un joint permanent entre le chauffe eau et le ch ssis du v hicule 4 Ins rez la bride de la porte dans le bo tier de...

Страница 20: ...ilisant un interrupteur int rieur non fourni ou en d sactivant le circuit du Chauffe Eau AVERTISSEMENT NE PAS utiliser d allumettes de bougies ou toute autre source d allumage pour v rifier lapr sence...

Страница 21: ...ENT AVERTISSEMENT CONSIGNES DE S CURIT DESTIN ES AU CONSOMMATEUR Utiliser uniquement avec du gaz de propane liquide Lors du r approvisionnement en carburant teindre les appareils gaz et les flammes pi...

Страница 22: ...re install e au niveau du raccord de sortie de l eau chaude du chauffe eau lors de l installation Les codes locaux doivent r gir l installation de toute soupape de d charge La soupape de d charge n es...

Страница 23: ...aison il est recommand de suivre la les recommandation s ci dessous si l unit doit tre entrepos e dans un environnement hivernal ou pour de longues p riodes de temps Au d but de la saison d hiver ou a...

Страница 24: ...ct avant l allumage ou pendant le fonctionnement normal Cela pourrait tre aussi caus par un d faut de c blage dans les connexions du moteur E6 Surtemp rature Temp rature de sortie d eau a d pass 140 F...

Страница 25: ...leentre la Carte de Contr le et l allumeur est bien en place et n est pas court circuit l un des composants m talliques 8 Au moins une fois par an activer la soupape de s curit pour v rifier que ther...

Страница 26: ...1 F2GWHDAS10 Bride Seulement 1 12 Charni re de porte 1 13a Anneau de Purge en silicone BLANC 1 13b Anneau de Purge en silicone NOIR 1 14a Verrou de porte BLANC 1 14b Verrou de porte NOIR 1 15 Ressort...

Страница 27: ...chauffage d eau comme indiqu sur la plaque signal tique attach e CARACT RISTIQUES Caract ristiques BTU HR 42 000 BTU carburant Propane LP Gas Inlet Pressure 11 WCI Min to 14 WCI Max Pression d admiss...

Страница 28: ...Coupure d urgence Capteur de niveau de cong lation Un diagramme des c blages des connexions lectriques l int rieur de l unit Cutting 1 Blue 2 Blue White White Blue Blue White Red Black Brown 5 Yellow...

Страница 29: ...az vanne d entr e 15 Br leur 16 Coquille Inf rieure 17 Tube de direction de la vanne de d compression 18 Soupape de d charge de pression 19 Conduite d eau Assy 20 Joint en caoutchouc 1 21 Assemblage d...