ASD-120 SEQUENCED POWER DISTRO
11
Remote Operating Modes
If the ASD-120 will be controlled locally only, you may skip this section and the
next section of the manual.
There are three remote operating modes available: Maintained Mode/Normally
On, which is the default, Maintained Mode/Normally Off, and Momentary Mode.
The Momentary Mode on the ASD-120 shares the same characteristics as the
Momentary Mode on the Furman PowerPort, MiniPorts, PowerLink and PS-PRO
and PS-8R Power Sequencers. Remote inputs (REM, FORCE ON, FORCE OFF)
are controlled by applying at least 5 VDC or 6 VAC between the input and the REM
COM terminal.
This is the default control logic on all of our existing and past power products.
However, the ASD-120’s inputs are enhanced in the following ways: (1) They are
polarity independent, and work with positive, negative or AC control signals.
(2) They are optically isolated. The remote control inputs have a floating common.
(3) They safely accept up to 130 VAC, for direct control from mains supply.
Maintained Mode/Normally On (Default)
In the absence of any signal applied to the remote input, the ASD-120 will se-
quence on as soon as power is applied, and the key switch is turned to REM
or ON. This is Maintained Mode/Normally On. In this mode, voltage must be con-
tinually applied to the REM input to keep the ASD-120’s outlets off, when the key
switch is in the REM position. This mode is compatible with all other Furman prod-
ucts’ REM inputs.
ASD-120 front panel (top) and rear panel (bottom)
+12V
STATUS
START
REM
FORCE
ON
FORCE
OFF
REM
COM
GND
RELAY
COM
F
A
B
C
D
E
LOAD
0A
AVIS:
RISQUE DE CHOC
ELECTRIQUE -- NE PAS OUVRIR
RISK OF ELECTRIC SHOCK.
DO NOT OPEN. REFER
SERVICING TO QUALIFIED
SERVICE PERSONNEL. TO
REDUCE THE RISK OF FIRE
OR ELECTRIC SHOCK DO NOT
EXPOSE THIS EQUIPMENT TO
RAIN AND MOISTURE.
CAUTION!
MADE IN THE USA
A
B
E
D